A theoretical and numerical approach to optimal positioning of the patellar surface replacement in a total knee endoprosthesis

Research output: Contribution to journalArticleResearchpeer review

Authors

  • Eduard Reithmeier
  • Wolfgang Plitz

External Research Organisations

  • Technical University of Munich (TUM)
  • Ludwig-Maximilians-Universität München (LMU)
View graph of relations

Details

Original languageEnglish
Pages (from-to)883-885, 887-892
JournalJournal of Biomechanics
Volume23
Issue number9
Publication statusPublished - 1990
Externally publishedYes

Abstract

The clinical results of total knee joint arthroplasty with patellar replacement have shown that postoperative problems arise, especially under unfavourable biomechanical conditions. The findings concerning retropatellar contact forces have been obtained by means of different methods, partly through experimental investigations and partly through theoretical considerations. But so far patellar replacement criteria and the resulting changes of the retropatellar contact force were not taken into consideration in other studies. Our mathematical model is based on a mechanical one and the parameter study considers the influence of the height of the patellar surface replacement upon different biomechanical parameters at varying positions. The results suggest that the patellar replacement should therefore be kept as low as possible, thus reducing the retropatellar contact force to a minimum, especially in the extremely stressed flexion areas of up to about 90°.

ASJC Scopus subject areas

Cite this

A theoretical and numerical approach to optimal positioning of the patellar surface replacement in a total knee endoprosthesis. / Reithmeier, Eduard; Plitz, Wolfgang.
In: Journal of Biomechanics, Vol. 23, No. 9, 1990, p. 883-885, 887-892.

Research output: Contribution to journalArticleResearchpeer review

Download
@article{17450bb9de7d40d9b08506e5fb95fbbe,
title = "A theoretical and numerical approach to optimal positioning of the patellar surface replacement in a total knee endoprosthesis",
abstract = "The clinical results of total knee joint arthroplasty with patellar replacement have shown that postoperative problems arise, especially under unfavourable biomechanical conditions. The findings concerning retropatellar contact forces have been obtained by means of different methods, partly through experimental investigations and partly through theoretical considerations. But so far patellar replacement criteria and the resulting changes of the retropatellar contact force were not taken into consideration in other studies. Our mathematical model is based on a mechanical one and the parameter study considers the influence of the height of the patellar surface replacement upon different biomechanical parameters at varying positions. The results suggest that the patellar replacement should therefore be kept as low as possible, thus reducing the retropatellar contact force to a minimum, especially in the extremely stressed flexion areas of up to about 90°.",
author = "Eduard Reithmeier and Wolfgang Plitz",
year = "1990",
doi = "10.1016/0021-9290(90)90353-5",
language = "English",
volume = "23",
pages = "883--885, 887--892",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Ltd.",
number = "9",

}

Download

TY - JOUR

T1 - A theoretical and numerical approach to optimal positioning of the patellar surface replacement in a total knee endoprosthesis

AU - Reithmeier, Eduard

AU - Plitz, Wolfgang

PY - 1990

Y1 - 1990

N2 - The clinical results of total knee joint arthroplasty with patellar replacement have shown that postoperative problems arise, especially under unfavourable biomechanical conditions. The findings concerning retropatellar contact forces have been obtained by means of different methods, partly through experimental investigations and partly through theoretical considerations. But so far patellar replacement criteria and the resulting changes of the retropatellar contact force were not taken into consideration in other studies. Our mathematical model is based on a mechanical one and the parameter study considers the influence of the height of the patellar surface replacement upon different biomechanical parameters at varying positions. The results suggest that the patellar replacement should therefore be kept as low as possible, thus reducing the retropatellar contact force to a minimum, especially in the extremely stressed flexion areas of up to about 90°.

AB - The clinical results of total knee joint arthroplasty with patellar replacement have shown that postoperative problems arise, especially under unfavourable biomechanical conditions. The findings concerning retropatellar contact forces have been obtained by means of different methods, partly through experimental investigations and partly through theoretical considerations. But so far patellar replacement criteria and the resulting changes of the retropatellar contact force were not taken into consideration in other studies. Our mathematical model is based on a mechanical one and the parameter study considers the influence of the height of the patellar surface replacement upon different biomechanical parameters at varying positions. The results suggest that the patellar replacement should therefore be kept as low as possible, thus reducing the retropatellar contact force to a minimum, especially in the extremely stressed flexion areas of up to about 90°.

UR - http://www.scopus.com/inward/record.url?scp=0025182937&partnerID=8YFLogxK

U2 - 10.1016/0021-9290(90)90353-5

DO - 10.1016/0021-9290(90)90353-5

M3 - Article

C2 - 2211733

AN - SCOPUS:0025182937

VL - 23

SP - 883-885, 887-892

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 9

ER -