Wind response control of tall buildings with a tuned mass damper

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Externe Organisationen

  • Indian Institute of Technology Delhi (IITD)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)51-60
Seitenumfang10
FachzeitschriftJournal of Building Engineering
Jahrgang15
PublikationsstatusVeröffentlicht - Jan. 2018
Extern publiziertJa

Abstract

Wind response control of tall buildings installed with a tuned mass damper (TMD) is investigated. The performance of a TMD installed at the topmost floor of a 76-storey benchmark building is compared with the TMD installed at different floors (locations) of the building. The TMD is placed where particular mode shape amplitude of the building is largest or larger. At each location, the performance of the TMD is examined by tuning it to the first few modal frequencies. The coupled differential equations of motion for the building without/with the TMD are derived and solved by employing Newmark's integration method. Variations in the normalized response of the controlled building under wind forces are computed to study the effectiveness of using different TMD schemes. Placement, tuning frequencies, mass and damping ratios of the devices are the parameters investigated to compare the effectiveness of these different TMD schemes. It is concluded that placement of the TMD shows a significant influence in improvement of the performance of the TMD, especially if it is tuned to the corresponding modal frequency. In addition, the optimally determined damping ratio reduces for the TMD tuned to the higher modal frequencies.

ASJC Scopus Sachgebiete

Zitieren

Wind response control of tall buildings with a tuned mass damper. / Elias, Said; Matsagar, Vasant.
in: Journal of Building Engineering, Jahrgang 15, 01.2018, S. 51-60.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Elias, S & Matsagar, V 2018, 'Wind response control of tall buildings with a tuned mass damper', Journal of Building Engineering, Jg. 15, S. 51-60. https://doi.org/10.1016/j.jobe.2017.11.005
Elias S, Matsagar V. Wind response control of tall buildings with a tuned mass damper. Journal of Building Engineering. 2018 Jan;15:51-60. doi: 10.1016/j.jobe.2017.11.005
Elias, Said ; Matsagar, Vasant. / Wind response control of tall buildings with a tuned mass damper. in: Journal of Building Engineering. 2018 ; Jahrgang 15. S. 51-60.
Download
@article{3c797499cfad4a649eda58df8cc6f019,
title = "Wind response control of tall buildings with a tuned mass damper",
abstract = "Wind response control of tall buildings installed with a tuned mass damper (TMD) is investigated. The performance of a TMD installed at the topmost floor of a 76-storey benchmark building is compared with the TMD installed at different floors (locations) of the building. The TMD is placed where particular mode shape amplitude of the building is largest or larger. At each location, the performance of the TMD is examined by tuning it to the first few modal frequencies. The coupled differential equations of motion for the building without/with the TMD are derived and solved by employing Newmark's integration method. Variations in the normalized response of the controlled building under wind forces are computed to study the effectiveness of using different TMD schemes. Placement, tuning frequencies, mass and damping ratios of the devices are the parameters investigated to compare the effectiveness of these different TMD schemes. It is concluded that placement of the TMD shows a significant influence in improvement of the performance of the TMD, especially if it is tuned to the corresponding modal frequency. In addition, the optimally determined damping ratio reduces for the TMD tuned to the higher modal frequencies.",
keywords = "Modal frequency/shape, Tall building, Tuned mass damper (TMD), Wind forces",
author = "Said Elias and Vasant Matsagar",
note = "Publisher Copyright: {\textcopyright} 2017 Elsevier Ltd",
year = "2018",
month = jan,
doi = "10.1016/j.jobe.2017.11.005",
language = "English",
volume = "15",
pages = "51--60",

}

Download

TY - JOUR

T1 - Wind response control of tall buildings with a tuned mass damper

AU - Elias, Said

AU - Matsagar, Vasant

N1 - Publisher Copyright: © 2017 Elsevier Ltd

PY - 2018/1

Y1 - 2018/1

N2 - Wind response control of tall buildings installed with a tuned mass damper (TMD) is investigated. The performance of a TMD installed at the topmost floor of a 76-storey benchmark building is compared with the TMD installed at different floors (locations) of the building. The TMD is placed where particular mode shape amplitude of the building is largest or larger. At each location, the performance of the TMD is examined by tuning it to the first few modal frequencies. The coupled differential equations of motion for the building without/with the TMD are derived and solved by employing Newmark's integration method. Variations in the normalized response of the controlled building under wind forces are computed to study the effectiveness of using different TMD schemes. Placement, tuning frequencies, mass and damping ratios of the devices are the parameters investigated to compare the effectiveness of these different TMD schemes. It is concluded that placement of the TMD shows a significant influence in improvement of the performance of the TMD, especially if it is tuned to the corresponding modal frequency. In addition, the optimally determined damping ratio reduces for the TMD tuned to the higher modal frequencies.

AB - Wind response control of tall buildings installed with a tuned mass damper (TMD) is investigated. The performance of a TMD installed at the topmost floor of a 76-storey benchmark building is compared with the TMD installed at different floors (locations) of the building. The TMD is placed where particular mode shape amplitude of the building is largest or larger. At each location, the performance of the TMD is examined by tuning it to the first few modal frequencies. The coupled differential equations of motion for the building without/with the TMD are derived and solved by employing Newmark's integration method. Variations in the normalized response of the controlled building under wind forces are computed to study the effectiveness of using different TMD schemes. Placement, tuning frequencies, mass and damping ratios of the devices are the parameters investigated to compare the effectiveness of these different TMD schemes. It is concluded that placement of the TMD shows a significant influence in improvement of the performance of the TMD, especially if it is tuned to the corresponding modal frequency. In addition, the optimally determined damping ratio reduces for the TMD tuned to the higher modal frequencies.

KW - Modal frequency/shape

KW - Tall building

KW - Tuned mass damper (TMD)

KW - Wind forces

UR - http://www.scopus.com/inward/record.url?scp=85033393704&partnerID=8YFLogxK

U2 - 10.1016/j.jobe.2017.11.005

DO - 10.1016/j.jobe.2017.11.005

M3 - Article

AN - SCOPUS:85033393704

VL - 15

SP - 51

EP - 60

JO - Journal of Building Engineering

JF - Journal of Building Engineering

ER -