Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

Externe Organisationen

  • Indian Institute of Technology Delhi (IITD)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksProceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013
Herausgeber/-innenNagesh R. Iyer, Prem Krishna, Rajan S. Selvi, P. Harikrishna
Seiten968-977
Seitenumfang10
ISBN (elektronisch)9789810780111
PublikationsstatusVeröffentlicht - 2013
Extern publiziertJa
Veranstaltung8th Asia-Pacific Conference on Wind Engineering, APCWE 2013 - Chennai, Indien
Dauer: 10 Dez. 201314 Dez. 2013

Publikationsreihe

NameProceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013

Abstract

Wind response control of a 76-storey benchmark building installed with distributed multiple tuned mass dampers (MTMDs) is investigated. The performance of the distributed MTMDs is compared with all MTMDs placed at top floor and with single tuned mass damper (STMD) having same total mass. The STMD is placed at top floor of the benchmark building; different mass ratios are given for STMD to improve performance of the building. The MTMDs are placed at top floor of the benchmark building; same way different mass ratios are given to MTMDs to improve performance of the building. The TMDs are placed where the mode shape amplitude of the buildings is the largest/large in the particular mode and each tuned with the corresponding modal frequency, while controlling first five modes in MTMDs. The mass ratios are varied to obtain improved performance of the building. It is concluded that MTMDs are more effective than the case of STMD, and further, the distributed MTMDs are more effective to control wind induced vibration of the building.

ASJC Scopus Sachgebiete

Ziele für nachhaltige Entwicklung

Zitieren

Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers. / Elias, Said; Matsagar, Vasant.
Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013. Hrsg. / Nagesh R. Iyer; Prem Krishna; Rajan S. Selvi; P. Harikrishna. 2013. S. 968-977 (Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Elias, S & Matsagar, V 2013, Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers. in NR Iyer, P Krishna, RS Selvi & P Harikrishna (Hrsg.), Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013. Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013, S. 968-977, 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013, Chennai, Indien, 10 Dez. 2013. https://doi.org/10.3850/978-981-07-8012-8_287
Elias, S., & Matsagar, V. (2013). Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers. In N. R. Iyer, P. Krishna, R. S. Selvi, & P. Harikrishna (Hrsg.), Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013 (S. 968-977). (Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013). https://doi.org/10.3850/978-981-07-8012-8_287
Elias S, Matsagar V. Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers. in Iyer NR, Krishna P, Selvi RS, Harikrishna P, Hrsg., Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013. 2013. S. 968-977. (Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013). doi: 10.3850/978-981-07-8012-8_287
Elias, Said ; Matsagar, Vasant. / Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers. Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013. Hrsg. / Nagesh R. Iyer ; Prem Krishna ; Rajan S. Selvi ; P. Harikrishna. 2013. S. 968-977 (Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013).
Download
@inproceedings{1ae96ea47fc5480480b58015efdff262,
title = "Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers",
abstract = "Wind response control of a 76-storey benchmark building installed with distributed multiple tuned mass dampers (MTMDs) is investigated. The performance of the distributed MTMDs is compared with all MTMDs placed at top floor and with single tuned mass damper (STMD) having same total mass. The STMD is placed at top floor of the benchmark building; different mass ratios are given for STMD to improve performance of the building. The MTMDs are placed at top floor of the benchmark building; same way different mass ratios are given to MTMDs to improve performance of the building. The TMDs are placed where the mode shape amplitude of the buildings is the largest/large in the particular mode and each tuned with the corresponding modal frequency, while controlling first five modes in MTMDs. The mass ratios are varied to obtain improved performance of the building. It is concluded that MTMDs are more effective than the case of STMD, and further, the distributed MTMDs are more effective to control wind induced vibration of the building.",
keywords = "Benchmark building, Distributed MTMDs, Modal frequency, Mode shape",
author = "Said Elias and Vasant Matsagar",
note = "Publisher Copyright: Copyright {\textcopyright} 2013 APCWE-VIII. All rights reserved. Published by Research Publishing, Singapore.; 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013 ; Conference date: 10-12-2013 Through 14-12-2013",
year = "2013",
doi = "10.3850/978-981-07-8012-8_287",
language = "English",
series = "Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013",
pages = "968--977",
editor = "Iyer, {Nagesh R.} and Prem Krishna and Selvi, {Rajan S.} and P. Harikrishna",
booktitle = "Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013",

}

Download

TY - GEN

T1 - Wind response control of 76-storey benchmark building with distributed multiple tuned mass dampers

AU - Elias, Said

AU - Matsagar, Vasant

N1 - Publisher Copyright: Copyright © 2013 APCWE-VIII. All rights reserved. Published by Research Publishing, Singapore.

PY - 2013

Y1 - 2013

N2 - Wind response control of a 76-storey benchmark building installed with distributed multiple tuned mass dampers (MTMDs) is investigated. The performance of the distributed MTMDs is compared with all MTMDs placed at top floor and with single tuned mass damper (STMD) having same total mass. The STMD is placed at top floor of the benchmark building; different mass ratios are given for STMD to improve performance of the building. The MTMDs are placed at top floor of the benchmark building; same way different mass ratios are given to MTMDs to improve performance of the building. The TMDs are placed where the mode shape amplitude of the buildings is the largest/large in the particular mode and each tuned with the corresponding modal frequency, while controlling first five modes in MTMDs. The mass ratios are varied to obtain improved performance of the building. It is concluded that MTMDs are more effective than the case of STMD, and further, the distributed MTMDs are more effective to control wind induced vibration of the building.

AB - Wind response control of a 76-storey benchmark building installed with distributed multiple tuned mass dampers (MTMDs) is investigated. The performance of the distributed MTMDs is compared with all MTMDs placed at top floor and with single tuned mass damper (STMD) having same total mass. The STMD is placed at top floor of the benchmark building; different mass ratios are given for STMD to improve performance of the building. The MTMDs are placed at top floor of the benchmark building; same way different mass ratios are given to MTMDs to improve performance of the building. The TMDs are placed where the mode shape amplitude of the buildings is the largest/large in the particular mode and each tuned with the corresponding modal frequency, while controlling first five modes in MTMDs. The mass ratios are varied to obtain improved performance of the building. It is concluded that MTMDs are more effective than the case of STMD, and further, the distributed MTMDs are more effective to control wind induced vibration of the building.

KW - Benchmark building

KW - Distributed MTMDs

KW - Modal frequency

KW - Mode shape

UR - http://www.scopus.com/inward/record.url?scp=85072176727&partnerID=8YFLogxK

U2 - 10.3850/978-981-07-8012-8_287

DO - 10.3850/978-981-07-8012-8_287

M3 - Conference contribution

AN - SCOPUS:85072176727

T3 - Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013

SP - 968

EP - 977

BT - Proceedings of the 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013

A2 - Iyer, Nagesh R.

A2 - Krishna, Prem

A2 - Selvi, Rajan S.

A2 - Harikrishna, P.

T2 - 8th Asia-Pacific Conference on Wind Engineering, APCWE 2013

Y2 - 10 December 2013 through 14 December 2013

ER -

Von denselben Autoren