White light transverse cooling of a helium beam

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • E. Rasel
  • F. Pereira Dos Santos
  • F. Saverio Pavone
  • F. Perales
  • C. S. Unnikrishnan
  • M. Leduc

Organisationseinheiten

Externe Organisationen

  • Tata Institute of Fundamental Research (TIFR HYD)
  • Université Paris 6
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)311-316
Seitenumfang6
FachzeitschriftEuropean Physical Journal D
Jahrgang7
Ausgabenummer3
PublikationsstatusVeröffentlicht - Okt. 1999

Abstract

We report a study of transverse laser cooling on a metastable helium beam using spectrally broadened diode lasers ("white light") to increase its flux. For this purpose, beam profile and atomic flux versus laser power and other parameters have been characterized. We have performed experiments to compare this technique with other transverse cooling methods using monochromatic light. Best results are obtained with a "ziz-zag" configuration using "white light".

ASJC Scopus Sachgebiete

Zitieren

White light transverse cooling of a helium beam. / Rasel, E.; Pereira Dos Santos, F.; Saverio Pavone, F. et al.
in: European Physical Journal D, Jahrgang 7, Nr. 3, 10.1999, S. 311-316.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Rasel, E, Pereira Dos Santos, F, Saverio Pavone, F, Perales, F, Unnikrishnan, CS & Leduc, M 1999, 'White light transverse cooling of a helium beam', European Physical Journal D, Jg. 7, Nr. 3, S. 311-316. https://doi.org/10.1007/s100530050573
Rasel, E., Pereira Dos Santos, F., Saverio Pavone, F., Perales, F., Unnikrishnan, C. S., & Leduc, M. (1999). White light transverse cooling of a helium beam. European Physical Journal D, 7(3), 311-316. https://doi.org/10.1007/s100530050573
Rasel E, Pereira Dos Santos F, Saverio Pavone F, Perales F, Unnikrishnan CS, Leduc M. White light transverse cooling of a helium beam. European Physical Journal D. 1999 Okt;7(3):311-316. doi: 10.1007/s100530050573
Rasel, E. ; Pereira Dos Santos, F. ; Saverio Pavone, F. et al. / White light transverse cooling of a helium beam. in: European Physical Journal D. 1999 ; Jahrgang 7, Nr. 3. S. 311-316.
Download
@article{84a9275a92dd4077a174e8124799ae07,
title = "White light transverse cooling of a helium beam",
abstract = "We report a study of transverse laser cooling on a metastable helium beam using spectrally broadened diode lasers ({"}white light{"}) to increase its flux. For this purpose, beam profile and atomic flux versus laser power and other parameters have been characterized. We have performed experiments to compare this technique with other transverse cooling methods using monochromatic light. Best results are obtained with a {"}ziz-zag{"} configuration using {"}white light{"}.",
author = "E. Rasel and {Pereira Dos Santos}, F. and {Saverio Pavone}, F. and F. Perales and Unnikrishnan, {C. S.} and M. Leduc",
year = "1999",
month = oct,
doi = "10.1007/s100530050573",
language = "English",
volume = "7",
pages = "311--316",
journal = "European Physical Journal D",
issn = "1434-6060",
publisher = "Springer New York",
number = "3",

}

Download

TY - JOUR

T1 - White light transverse cooling of a helium beam

AU - Rasel, E.

AU - Pereira Dos Santos, F.

AU - Saverio Pavone, F.

AU - Perales, F.

AU - Unnikrishnan, C. S.

AU - Leduc, M.

PY - 1999/10

Y1 - 1999/10

N2 - We report a study of transverse laser cooling on a metastable helium beam using spectrally broadened diode lasers ("white light") to increase its flux. For this purpose, beam profile and atomic flux versus laser power and other parameters have been characterized. We have performed experiments to compare this technique with other transverse cooling methods using monochromatic light. Best results are obtained with a "ziz-zag" configuration using "white light".

AB - We report a study of transverse laser cooling on a metastable helium beam using spectrally broadened diode lasers ("white light") to increase its flux. For this purpose, beam profile and atomic flux versus laser power and other parameters have been characterized. We have performed experiments to compare this technique with other transverse cooling methods using monochromatic light. Best results are obtained with a "ziz-zag" configuration using "white light".

UR - http://www.scopus.com/inward/record.url?scp=0033474598&partnerID=8YFLogxK

U2 - 10.1007/s100530050573

DO - 10.1007/s100530050573

M3 - Article

AN - SCOPUS:0033474598

VL - 7

SP - 311

EP - 316

JO - European Physical Journal D

JF - European Physical Journal D

SN - 1434-6060

IS - 3

ER -