Details
Originalsprache | Englisch |
---|---|
Titel des Sammelwerks | Proceedings of SPIE - The International Society for Optical Engineering |
Seiten | 58-69 |
Seitenumfang | 12 |
Publikationsstatus | Veröffentlicht - 1995 |
Veranstaltung | Optical Sensing for Environmental and Process Monitoring - McLean, VA, USA Dauer: 6 Nov. 1994 → 6 Nov. 1994 |
Publikationsreihe
Name | Proceedings of SPIE - The International Society for Optical Engineering |
---|---|
Band | 2365 |
ISSN (Print) | 0277-786X |
Abstract
A pulsed-molecular-beam Fabry-Perot cavity Fourier-transform microwave spectrometer developed at NIST has demonstrated sensitivities for many polar gas-phase molecular species in the low parts per million (ppm) to parts per billion (ppb) range. The highest sensitivity is obtained using neon or argon carrier gas but nitrogen or air can also be used, with some loss in sensitivity (up to 100 times) due to the less efficient rotational and vibrational cooling in the molecular beam with diatomic gases. The minimum detectable concentrations for several representative compounds are provided. These include acetaldehyde, acrolein, propionaldhyde, benzaldehyde, p-tolualdehyde, methanol, SO 2, propene, methyl t-butyl ether, ethyl t-butyl ether, and others. Considerable attention has been given to making the instrument versatile and user friendly. The instrument is computer controlled using standard GPIB interfaces and several graphical interfaces under the CPLUPLU operating system.
ASJC Scopus Sachgebiete
- Werkstoffwissenschaften (insg.)
- Elektronische, optische und magnetische Materialien
- Physik und Astronomie (insg.)
- Physik der kondensierten Materie
- Informatik (insg.)
- Angewandte Informatik
- Mathematik (insg.)
- Angewandte Mathematik
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
Proceedings of SPIE - The International Society for Optical Engineering. 1995. S. 58-69 (Proceedings of SPIE - The International Society for Optical Engineering; Band 2365).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Using Fourier transform microwave spectroscopy to detect pollutants
AU - Lovas, F. J.
AU - Pereyra, W.
AU - Suenram, R. D.
AU - Fraser, G. T.
AU - Grabow, J. U.
AU - Hight Walker, A. R.
PY - 1995
Y1 - 1995
N2 - A pulsed-molecular-beam Fabry-Perot cavity Fourier-transform microwave spectrometer developed at NIST has demonstrated sensitivities for many polar gas-phase molecular species in the low parts per million (ppm) to parts per billion (ppb) range. The highest sensitivity is obtained using neon or argon carrier gas but nitrogen or air can also be used, with some loss in sensitivity (up to 100 times) due to the less efficient rotational and vibrational cooling in the molecular beam with diatomic gases. The minimum detectable concentrations for several representative compounds are provided. These include acetaldehyde, acrolein, propionaldhyde, benzaldehyde, p-tolualdehyde, methanol, SO 2, propene, methyl t-butyl ether, ethyl t-butyl ether, and others. Considerable attention has been given to making the instrument versatile and user friendly. The instrument is computer controlled using standard GPIB interfaces and several graphical interfaces under the CPLUPLU operating system.
AB - A pulsed-molecular-beam Fabry-Perot cavity Fourier-transform microwave spectrometer developed at NIST has demonstrated sensitivities for many polar gas-phase molecular species in the low parts per million (ppm) to parts per billion (ppb) range. The highest sensitivity is obtained using neon or argon carrier gas but nitrogen or air can also be used, with some loss in sensitivity (up to 100 times) due to the less efficient rotational and vibrational cooling in the molecular beam with diatomic gases. The minimum detectable concentrations for several representative compounds are provided. These include acetaldehyde, acrolein, propionaldhyde, benzaldehyde, p-tolualdehyde, methanol, SO 2, propene, methyl t-butyl ether, ethyl t-butyl ether, and others. Considerable attention has been given to making the instrument versatile and user friendly. The instrument is computer controlled using standard GPIB interfaces and several graphical interfaces under the CPLUPLU operating system.
UR - http://www.scopus.com/inward/record.url?scp=0029233149&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:0029233149
SN - 0819417114
T3 - Proceedings of SPIE - The International Society for Optical Engineering
SP - 58
EP - 69
BT - Proceedings of SPIE - The International Society for Optical Engineering
T2 - Optical Sensing for Environmental and Process Monitoring
Y2 - 6 November 1994 through 6 November 1994
ER -