Towards the Development of an In-Process Quality Monitoring System for Polyethylene Recyclates by Pyrolysis Gas Chromatography Ion Mobility Spectrometry

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)6045-6054
Seitenumfang10
FachzeitschriftJournal of Polymers and the Environment
Jahrgang32
Ausgabenummer11
Frühes Online-Datum17 Juli 2024
PublikationsstatusVeröffentlicht - Nov. 2024

Abstract

Over the past few decades, the topic of recycling has become increasingly prominent in the field of sustainable materials and circular economy. One significant challenge is the physical separation of different types of plastics to obtain recyclates of one plastic type as pure as possible with comparable quality and properties to those of virgin material. Given the substantial effort involved in such separation, small amounts of contamination from other plastics may be tolerated. However, these contaminations must be monitored to ensure high-level recyclate quality. In recent years, compact, low-cost ion mobility spectrometers (IMS) with high analytical performance have been developed, and have thus become widely used in a variety of sensing applications. Due to their high sensitivity, IMS are particularly suited for detecting lowest concentration levels of various compounds, as required for the detection of impurities in recyclate quality monitoring. When coupled to a miniature gas chromatograph (GC), GC-IMS reach even higher separation power while being still compact. To bring recyclate samples to the gas phase, pyrolysis (Py) is used in this work. A first feasibility study was conducted to assess the potential of such a pyrolysis–gas chromatography-ion mobility spectrometer (Py-GC-IMS) with the objective of detecting contaminations of polyethylene terephthalate (PET) in polyethylene (PE) recyclates. The study clearly demonstrates the ability to identify PET-related fingerprints while suppressing the PE background matrix by design so that Py-GC-IMS seems a promising approach for in-process monitoring PET contaminations in PE recyclates.

ASJC Scopus Sachgebiete

Ziele für nachhaltige Entwicklung

Zitieren

Towards the Development of an In-Process Quality Monitoring System for Polyethylene Recyclates by Pyrolysis Gas Chromatography Ion Mobility Spectrometry. / Ahrens, André; Shamsuyeva, Madina; Endres, Hans Josef et al.
in: Journal of Polymers and the Environment, Jahrgang 32, Nr. 11, 11.2024, S. 6045-6054.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{532c15c627d14f259f486435a274c6da,
title = "Towards the Development of an In-Process Quality Monitoring System for Polyethylene Recyclates by Pyrolysis Gas Chromatography Ion Mobility Spectrometry",
abstract = "Over the past few decades, the topic of recycling has become increasingly prominent in the field of sustainable materials and circular economy. One significant challenge is the physical separation of different types of plastics to obtain recyclates of one plastic type as pure as possible with comparable quality and properties to those of virgin material. Given the substantial effort involved in such separation, small amounts of contamination from other plastics may be tolerated. However, these contaminations must be monitored to ensure high-level recyclate quality. In recent years, compact, low-cost ion mobility spectrometers (IMS) with high analytical performance have been developed, and have thus become widely used in a variety of sensing applications. Due to their high sensitivity, IMS are particularly suited for detecting lowest concentration levels of various compounds, as required for the detection of impurities in recyclate quality monitoring. When coupled to a miniature gas chromatograph (GC), GC-IMS reach even higher separation power while being still compact. To bring recyclate samples to the gas phase, pyrolysis (Py) is used in this work. A first feasibility study was conducted to assess the potential of such a pyrolysis–gas chromatography-ion mobility spectrometer (Py-GC-IMS) with the objective of detecting contaminations of polyethylene terephthalate (PET) in polyethylene (PE) recyclates. The study clearly demonstrates the ability to identify PET-related fingerprints while suppressing the PE background matrix by design so that Py-GC-IMS seems a promising approach for in-process monitoring PET contaminations in PE recyclates.",
keywords = "Gas chromatography, Ion mobility spectrometry, Polyethylene, Polyethylene terephthalate, Pyrolysis, Recyclates",
author = "Andr{\'e} Ahrens and Madina Shamsuyeva and Endres, {Hans Josef} and Stefan Zimmermann",
note = "Publisher Copyright: {\textcopyright} The Author(s) 2024.",
year = "2024",
month = nov,
doi = "10.1007/s10924-024-03362-x",
language = "English",
volume = "32",
pages = "6045--6054",
journal = "Journal of Polymers and the Environment",
issn = "1566-2543",
publisher = "Springer New York",
number = "11",

}

Download

TY - JOUR

T1 - Towards the Development of an In-Process Quality Monitoring System for Polyethylene Recyclates by Pyrolysis Gas Chromatography Ion Mobility Spectrometry

AU - Ahrens, André

AU - Shamsuyeva, Madina

AU - Endres, Hans Josef

AU - Zimmermann, Stefan

N1 - Publisher Copyright: © The Author(s) 2024.

PY - 2024/11

Y1 - 2024/11

N2 - Over the past few decades, the topic of recycling has become increasingly prominent in the field of sustainable materials and circular economy. One significant challenge is the physical separation of different types of plastics to obtain recyclates of one plastic type as pure as possible with comparable quality and properties to those of virgin material. Given the substantial effort involved in such separation, small amounts of contamination from other plastics may be tolerated. However, these contaminations must be monitored to ensure high-level recyclate quality. In recent years, compact, low-cost ion mobility spectrometers (IMS) with high analytical performance have been developed, and have thus become widely used in a variety of sensing applications. Due to their high sensitivity, IMS are particularly suited for detecting lowest concentration levels of various compounds, as required for the detection of impurities in recyclate quality monitoring. When coupled to a miniature gas chromatograph (GC), GC-IMS reach even higher separation power while being still compact. To bring recyclate samples to the gas phase, pyrolysis (Py) is used in this work. A first feasibility study was conducted to assess the potential of such a pyrolysis–gas chromatography-ion mobility spectrometer (Py-GC-IMS) with the objective of detecting contaminations of polyethylene terephthalate (PET) in polyethylene (PE) recyclates. The study clearly demonstrates the ability to identify PET-related fingerprints while suppressing the PE background matrix by design so that Py-GC-IMS seems a promising approach for in-process monitoring PET contaminations in PE recyclates.

AB - Over the past few decades, the topic of recycling has become increasingly prominent in the field of sustainable materials and circular economy. One significant challenge is the physical separation of different types of plastics to obtain recyclates of one plastic type as pure as possible with comparable quality and properties to those of virgin material. Given the substantial effort involved in such separation, small amounts of contamination from other plastics may be tolerated. However, these contaminations must be monitored to ensure high-level recyclate quality. In recent years, compact, low-cost ion mobility spectrometers (IMS) with high analytical performance have been developed, and have thus become widely used in a variety of sensing applications. Due to their high sensitivity, IMS are particularly suited for detecting lowest concentration levels of various compounds, as required for the detection of impurities in recyclate quality monitoring. When coupled to a miniature gas chromatograph (GC), GC-IMS reach even higher separation power while being still compact. To bring recyclate samples to the gas phase, pyrolysis (Py) is used in this work. A first feasibility study was conducted to assess the potential of such a pyrolysis–gas chromatography-ion mobility spectrometer (Py-GC-IMS) with the objective of detecting contaminations of polyethylene terephthalate (PET) in polyethylene (PE) recyclates. The study clearly demonstrates the ability to identify PET-related fingerprints while suppressing the PE background matrix by design so that Py-GC-IMS seems a promising approach for in-process monitoring PET contaminations in PE recyclates.

KW - Gas chromatography

KW - Ion mobility spectrometry

KW - Polyethylene

KW - Polyethylene terephthalate

KW - Pyrolysis

KW - Recyclates

UR - http://www.scopus.com/inward/record.url?scp=85198832476&partnerID=8YFLogxK

U2 - 10.1007/s10924-024-03362-x

DO - 10.1007/s10924-024-03362-x

M3 - Article

AN - SCOPUS:85198832476

VL - 32

SP - 6045

EP - 6054

JO - Journal of Polymers and the Environment

JF - Journal of Polymers and the Environment

SN - 1566-2543

IS - 11

ER -

Von denselben Autoren