Abstract
In this paper the present problems with the evaluation methods for lightning impulse parameters as defined in IEC 60060-1, are described. Also the current practice of evaluation in many laboratories world-wide, that is obtained by a questionnaire, is presented. Some of the work performed up the present time and the initial conclusions are reported, then some recommendations are made for future work.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
IEE Conference Publication. 467. Aufl. 1999. S. 1.49.S3-1.52.S3 (IEE Conference Publication; Band 1, Nr. 467).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Today's problems with the evaluation methods of full lightning impulse parameters as described in IEC 60060-1
AU - Berlijn, S.
AU - Kvarngren, M.
AU - Garnacho, F.
AU - Simon, Pascual
AU - Gockenbach, E.
AU - Werle, P.
AU - Hackemack, K.
AU - Watts, M.
AU - Wong, K. C.P.
N1 - Copyright: Copyright 2007 Elsevier B.V., All rights reserved.
PY - 1999
Y1 - 1999
N2 - In this paper the present problems with the evaluation methods for lightning impulse parameters as defined in IEC 60060-1, are described. Also the current practice of evaluation in many laboratories world-wide, that is obtained by a questionnaire, is presented. Some of the work performed up the present time and the initial conclusions are reported, then some recommendations are made for future work.
AB - In this paper the present problems with the evaluation methods for lightning impulse parameters as defined in IEC 60060-1, are described. Also the current practice of evaluation in many laboratories world-wide, that is obtained by a questionnaire, is presented. Some of the work performed up the present time and the initial conclusions are reported, then some recommendations are made for future work.
UR - http://www.scopus.com/inward/record.url?scp=17144447460&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:17144447460
SN - 0852967195
T3 - IEE Conference Publication
SP - 1.49.S3-1.52.S3
BT - IEE Conference Publication
T2 - 1999 11th International Symposium on 'High Voltage Engineering' (ish99)
Y2 - 23 August 1999 through 27 August 1999
ER -