Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

  • M. Rost
  • D. Piester
  • W. Yang
  • T. Feldmann
  • T. Wübbena
  • A. Bauch

Organisationseinheiten

Externe Organisationen

  • Physikalisch-Technische Bundesanstalt (PTB)
  • National University of Defense Technology
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)772-778
Seitenumfang7
FachzeitschriftMETROLOGIA
Jahrgang49
Ausgabenummer6
Frühes Online-Datum30 Okt. 2012
PublikationsstatusVeröffentlicht - Dez. 2012

Abstract

We demonstrate the capability of accurate time transfer using optical fibres over long distances utilizing a dark fibre and hardware which is usually employed in two-way satellite time and frequency transfer (TWSTFT). Our time transfer through optical fibre (TTTOF) system is a variant of the standard TWSTFT by employing an optical fibre in the transmission path instead of free-space transmission of signals between two ground stations through geostationary satellites. As we use a dark fibre there are practically no limitations to the bandwidth of the transmitted signals so that we can use the highest chip rate of the binary phase-shift modulation available from the commercial equipment. This leads to an enhanced precision compared with satellite time transfer where the occupied bandwidth is limited for cost reasons. The TTTOF system has been characterized and calibrated in a common-clock experiment at PTB, and the combined calibration uncertainty is estimated as 74 ps. In a second step the remote part of the system was operated at Leibniz Universität Hannover, Institut für Quantenoptik (IQ) separated by 73 km from PTB in Braunschweig. In parallel, a GPS time transfer link between Braunschweig and Hannover was established, and both links connected a passive hydrogen maser at IQ with the reference time scale UTC(PTB) maintained in PTB. The results obtained with both links agree within the 1- uncertainty of the GPS link results, which is estimated as 0.72 ns. The fibre link exhibits a nearly ten-fold improved stability compared with the GPS link, and assessment of its performance has been limited by the properties of the passive maser.

ASJC Scopus Sachgebiete

Zitieren

Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps. / Rost, M.; Piester, D.; Yang, W. et al.
in: METROLOGIA, Jahrgang 49, Nr. 6, 12.2012, S. 772-778.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Rost M, Piester D, Yang W, Feldmann T, Wübbena T, Bauch A. Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps. METROLOGIA. 2012 Dez;49(6):772-778. Epub 2012 Okt 30. doi: 10.48550/arXiv.1209.4467, 10.1088/0026-1394/49/6/772
Rost, M. ; Piester, D. ; Yang, W. et al. / Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps. in: METROLOGIA. 2012 ; Jahrgang 49, Nr. 6. S. 772-778.
Download
@article{1121a9bb80fd4659beccd086f2b7ec03,
title = "Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps",
abstract = "We demonstrate the capability of accurate time transfer using optical fibres over long distances utilizing a dark fibre and hardware which is usually employed in two-way satellite time and frequency transfer (TWSTFT). Our time transfer through optical fibre (TTTOF) system is a variant of the standard TWSTFT by employing an optical fibre in the transmission path instead of free-space transmission of signals between two ground stations through geostationary satellites. As we use a dark fibre there are practically no limitations to the bandwidth of the transmitted signals so that we can use the highest chip rate of the binary phase-shift modulation available from the commercial equipment. This leads to an enhanced precision compared with satellite time transfer where the occupied bandwidth is limited for cost reasons. The TTTOF system has been characterized and calibrated in a common-clock experiment at PTB, and the combined calibration uncertainty is estimated as 74 ps. In a second step the remote part of the system was operated at Leibniz Universit{\"a}t Hannover, Institut f{\"u}r Quantenoptik (IQ) separated by 73 km from PTB in Braunschweig. In parallel, a GPS time transfer link between Braunschweig and Hannover was established, and both links connected a passive hydrogen maser at IQ with the reference time scale UTC(PTB) maintained in PTB. The results obtained with both links agree within the 1- uncertainty of the GPS link results, which is estimated as 0.72 ns. The fibre link exhibits a nearly ten-fold improved stability compared with the GPS link, and assessment of its performance has been limited by the properties of the passive maser.",
author = "M. Rost and D. Piester and W. Yang and T. Feldmann and T. W{\"u}bbena and A. Bauch",
year = "2012",
month = dec,
doi = "10.48550/arXiv.1209.4467",
language = "English",
volume = "49",
pages = "772--778",
journal = "METROLOGIA",
issn = "0026-1394",
publisher = "IOP Publishing Ltd.",
number = "6",

}

Download

TY - JOUR

T1 - Time transfer through optical fibres over a distance of 73 km with an uncertainty below 100 ps

AU - Rost, M.

AU - Piester, D.

AU - Yang, W.

AU - Feldmann, T.

AU - Wübbena, T.

AU - Bauch, A.

PY - 2012/12

Y1 - 2012/12

N2 - We demonstrate the capability of accurate time transfer using optical fibres over long distances utilizing a dark fibre and hardware which is usually employed in two-way satellite time and frequency transfer (TWSTFT). Our time transfer through optical fibre (TTTOF) system is a variant of the standard TWSTFT by employing an optical fibre in the transmission path instead of free-space transmission of signals between two ground stations through geostationary satellites. As we use a dark fibre there are practically no limitations to the bandwidth of the transmitted signals so that we can use the highest chip rate of the binary phase-shift modulation available from the commercial equipment. This leads to an enhanced precision compared with satellite time transfer where the occupied bandwidth is limited for cost reasons. The TTTOF system has been characterized and calibrated in a common-clock experiment at PTB, and the combined calibration uncertainty is estimated as 74 ps. In a second step the remote part of the system was operated at Leibniz Universität Hannover, Institut für Quantenoptik (IQ) separated by 73 km from PTB in Braunschweig. In parallel, a GPS time transfer link between Braunschweig and Hannover was established, and both links connected a passive hydrogen maser at IQ with the reference time scale UTC(PTB) maintained in PTB. The results obtained with both links agree within the 1- uncertainty of the GPS link results, which is estimated as 0.72 ns. The fibre link exhibits a nearly ten-fold improved stability compared with the GPS link, and assessment of its performance has been limited by the properties of the passive maser.

AB - We demonstrate the capability of accurate time transfer using optical fibres over long distances utilizing a dark fibre and hardware which is usually employed in two-way satellite time and frequency transfer (TWSTFT). Our time transfer through optical fibre (TTTOF) system is a variant of the standard TWSTFT by employing an optical fibre in the transmission path instead of free-space transmission of signals between two ground stations through geostationary satellites. As we use a dark fibre there are practically no limitations to the bandwidth of the transmitted signals so that we can use the highest chip rate of the binary phase-shift modulation available from the commercial equipment. This leads to an enhanced precision compared with satellite time transfer where the occupied bandwidth is limited for cost reasons. The TTTOF system has been characterized and calibrated in a common-clock experiment at PTB, and the combined calibration uncertainty is estimated as 74 ps. In a second step the remote part of the system was operated at Leibniz Universität Hannover, Institut für Quantenoptik (IQ) separated by 73 km from PTB in Braunschweig. In parallel, a GPS time transfer link between Braunschweig and Hannover was established, and both links connected a passive hydrogen maser at IQ with the reference time scale UTC(PTB) maintained in PTB. The results obtained with both links agree within the 1- uncertainty of the GPS link results, which is estimated as 0.72 ns. The fibre link exhibits a nearly ten-fold improved stability compared with the GPS link, and assessment of its performance has been limited by the properties of the passive maser.

UR - http://www.scopus.com/inward/record.url?scp=84870286101&partnerID=8YFLogxK

U2 - 10.48550/arXiv.1209.4467

DO - 10.48550/arXiv.1209.4467

M3 - Article

AN - SCOPUS:84870286101

VL - 49

SP - 772

EP - 778

JO - METROLOGIA

JF - METROLOGIA

SN - 0026-1394

IS - 6

ER -