Abstract
The European Free Electron Laser (FEL) at ELETTRA has recently increased its maximum operating energy up to 1.5 GeV, the highest electron-beam energy used so far for an FEL. This is an important improvement in the performance of the source, increasing the extracted power at wavelengths around 200 nm and providing better beam stability and lifetime. Furthermore, this development represents a first step towards the solution of a crucial issue - the compatibility of FEL and normal synchrotron radiation operation at a user facility like ELETTRA. In this paper we discuss the most important aspects of this issue; in particular, we show that the properties of the electron beam in FEL mode can match the needs of normal synchrotron radiation experiments that require a few bunch filling of the storage ring.
ASJC Scopus Sachgebiete
- Physik und Astronomie (insg.)
- Kern- und Hochenergiephysik
- Physik und Astronomie (insg.)
- Instrumentierung
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Jahrgang 507, Nr. 1-2, 08.04.2003, S. 274-280.
Publikation: Beitrag in Fachzeitschrift › Konferenzaufsatz in Fachzeitschrift › Forschung › Peer-Review
}
TY - JOUR
T1 - The UV European FEL at ELETTRA
T2 - 24th International Free Electron Laser Conference
AU - De Ninno, G.
AU - Trovò, Mauro
AU - Danailov, Miltcho Boyanov
AU - Marsi, Mariano
AU - Karantzoulis, E.
AU - Diviacco, B.
AU - Walker, R. P.
AU - Bartolini, R.
AU - Dattoli, G.
AU - Giannessi, L.
AU - Mezi, L.
AU - Couprie, M. E.
AU - Gatto, Alexandre
AU - Kaiser, Norbert
AU - Günster, Stefan
AU - Ristau, Detlev
N1 - Funding information: The support given by EUFELE, a Project funded by the European Commission under FP5 Contract No. HPRI-CT-2001-50025, is acknowledged. It is also a pleasure to thank the staff at Daresbury Laboratory (Jim Clarke, R. Marl, I.D. Mullacrane) for the assistance in maintaining the mirror vacuum chamber, the accelerator staff at Sincrotrone Trieste (and, in particular, F. Iazzourene, L. Tosi) for the experimental support, M. Coreno for providing information about the experiment performed on the Gas Phase beamline. The support of TMR network ERB4061PL97-0102 is also acknowledged.
PY - 2003/4/8
Y1 - 2003/4/8
N2 - The European Free Electron Laser (FEL) at ELETTRA has recently increased its maximum operating energy up to 1.5 GeV, the highest electron-beam energy used so far for an FEL. This is an important improvement in the performance of the source, increasing the extracted power at wavelengths around 200 nm and providing better beam stability and lifetime. Furthermore, this development represents a first step towards the solution of a crucial issue - the compatibility of FEL and normal synchrotron radiation operation at a user facility like ELETTRA. In this paper we discuss the most important aspects of this issue; in particular, we show that the properties of the electron beam in FEL mode can match the needs of normal synchrotron radiation experiments that require a few bunch filling of the storage ring.
AB - The European Free Electron Laser (FEL) at ELETTRA has recently increased its maximum operating energy up to 1.5 GeV, the highest electron-beam energy used so far for an FEL. This is an important improvement in the performance of the source, increasing the extracted power at wavelengths around 200 nm and providing better beam stability and lifetime. Furthermore, this development represents a first step towards the solution of a crucial issue - the compatibility of FEL and normal synchrotron radiation operation at a user facility like ELETTRA. In this paper we discuss the most important aspects of this issue; in particular, we show that the properties of the electron beam in FEL mode can match the needs of normal synchrotron radiation experiments that require a few bunch filling of the storage ring.
KW - Free electron laser
KW - Storage ring
UR - http://www.scopus.com/inward/record.url?scp=0042672671&partnerID=8YFLogxK
U2 - 10.1016/S0168-9002(03)00928-8
DO - 10.1016/S0168-9002(03)00928-8
M3 - Conference article
AN - SCOPUS:0042672671
VL - 507
SP - 274
EP - 280
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
SN - 0168-9002
IS - 1-2
Y2 - 9 September 2002 through 13 September 2002
ER -