Successful testing of the LISA Technology Package (LTP) interferometer engineering model

Publikation: Beitrag in FachzeitschriftKonferenzaufsatz in FachzeitschriftForschungPeer-Review

Autoren

  • G. Heinzel
  • C. Braxmaier
  • M. Caldwell
  • K. Danzmann
  • F. Draaisma
  • A. García
  • J. Hough
  • O. Jennrich
  • U. Johann
  • C. Killow
  • K. Middleton
  • M. Te Plate
  • D. Robertson
  • A. Rüdiger
  • R. Schilling
  • F. Steier
  • V. Wand
  • H. Ward

Externe Organisationen

  • Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut)
  • Airbus Group
  • Rutherford Appleton Laboratory (RAL)
  • Niederländische Organisation für Angewandte Naturwissenschaftliche Forschung (TNO)
  • University of Glasgow
  • Europäische Weltraumforschungs- und Technologiezentrum (ESTEC)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)S149-S154
FachzeitschriftClassical and quantum gravity
Jahrgang22
Ausgabenummer10
PublikationsstatusVeröffentlicht - 21 Mai 2005

Abstract

The LISA Technology Package (LTP), to be launched by ESA in 2008, is a technology demonstration mission in preparation for the LISA space-borne gravitational wave detector. A central part of the LTP is the optical metrology package (heterodyne interferometer with phasemeter) that measures the distance between two test masses with a noise level of 10 pm Hz-1/2 between 3 mHz and 30 mHz and also the test mass alignment with a noise level of <10 nrad Hz-1/2. An engineering model of the interferometer has been built and environmentally tested. Extensive functionality and performance tests were conducted. This paper reports on the successful test results.

ASJC Scopus Sachgebiete

Zitieren

Successful testing of the LISA Technology Package (LTP) interferometer engineering model. / Heinzel, G.; Braxmaier, C.; Caldwell, M. et al.
in: Classical and quantum gravity, Jahrgang 22, Nr. 10, 21.05.2005, S. S149-S154.

Publikation: Beitrag in FachzeitschriftKonferenzaufsatz in FachzeitschriftForschungPeer-Review

Heinzel, G, Braxmaier, C, Caldwell, M, Danzmann, K, Draaisma, F, García, A, Hough, J, Jennrich, O, Johann, U, Killow, C, Middleton, K, Te Plate, M, Robertson, D, Rüdiger, A, Schilling, R, Steier, F, Wand, V & Ward, H 2005, 'Successful testing of the LISA Technology Package (LTP) interferometer engineering model', Classical and quantum gravity, Jg. 22, Nr. 10, S. S149-S154. https://doi.org/10.1088/0264-9381/22/10/003
Heinzel, G., Braxmaier, C., Caldwell, M., Danzmann, K., Draaisma, F., García, A., Hough, J., Jennrich, O., Johann, U., Killow, C., Middleton, K., Te Plate, M., Robertson, D., Rüdiger, A., Schilling, R., Steier, F., Wand, V., & Ward, H. (2005). Successful testing of the LISA Technology Package (LTP) interferometer engineering model. Classical and quantum gravity, 22(10), S149-S154. https://doi.org/10.1088/0264-9381/22/10/003
Heinzel G, Braxmaier C, Caldwell M, Danzmann K, Draaisma F, García A et al. Successful testing of the LISA Technology Package (LTP) interferometer engineering model. Classical and quantum gravity. 2005 Mai 21;22(10):S149-S154. doi: 10.1088/0264-9381/22/10/003
Heinzel, G. ; Braxmaier, C. ; Caldwell, M. et al. / Successful testing of the LISA Technology Package (LTP) interferometer engineering model. in: Classical and quantum gravity. 2005 ; Jahrgang 22, Nr. 10. S. S149-S154.
Download
@article{7729115c83814f4198d8eb99c54bdd7d,
title = "Successful testing of the LISA Technology Package (LTP) interferometer engineering model",
abstract = "The LISA Technology Package (LTP), to be launched by ESA in 2008, is a technology demonstration mission in preparation for the LISA space-borne gravitational wave detector. A central part of the LTP is the optical metrology package (heterodyne interferometer with phasemeter) that measures the distance between two test masses with a noise level of 10 pm Hz-1/2 between 3 mHz and 30 mHz and also the test mass alignment with a noise level of <10 nrad Hz-1/2. An engineering model of the interferometer has been built and environmentally tested. Extensive functionality and performance tests were conducted. This paper reports on the successful test results.",
author = "G. Heinzel and C. Braxmaier and M. Caldwell and K. Danzmann and F. Draaisma and A. Garc{\'i}a and J. Hough and O. Jennrich and U. Johann and C. Killow and K. Middleton and {Te Plate}, M. and D. Robertson and A. R{\"u}diger and R. Schilling and F. Steier and V. Wand and H. Ward",
year = "2005",
month = may,
day = "21",
doi = "10.1088/0264-9381/22/10/003",
language = "English",
volume = "22",
pages = "S149--S154",
journal = "Classical and quantum gravity",
issn = "0264-9381",
publisher = "IOP Publishing Ltd.",
number = "10",

}

Download

TY - JOUR

T1 - Successful testing of the LISA Technology Package (LTP) interferometer engineering model

AU - Heinzel, G.

AU - Braxmaier, C.

AU - Caldwell, M.

AU - Danzmann, K.

AU - Draaisma, F.

AU - García, A.

AU - Hough, J.

AU - Jennrich, O.

AU - Johann, U.

AU - Killow, C.

AU - Middleton, K.

AU - Te Plate, M.

AU - Robertson, D.

AU - Rüdiger, A.

AU - Schilling, R.

AU - Steier, F.

AU - Wand, V.

AU - Ward, H.

PY - 2005/5/21

Y1 - 2005/5/21

N2 - The LISA Technology Package (LTP), to be launched by ESA in 2008, is a technology demonstration mission in preparation for the LISA space-borne gravitational wave detector. A central part of the LTP is the optical metrology package (heterodyne interferometer with phasemeter) that measures the distance between two test masses with a noise level of 10 pm Hz-1/2 between 3 mHz and 30 mHz and also the test mass alignment with a noise level of <10 nrad Hz-1/2. An engineering model of the interferometer has been built and environmentally tested. Extensive functionality and performance tests were conducted. This paper reports on the successful test results.

AB - The LISA Technology Package (LTP), to be launched by ESA in 2008, is a technology demonstration mission in preparation for the LISA space-borne gravitational wave detector. A central part of the LTP is the optical metrology package (heterodyne interferometer with phasemeter) that measures the distance between two test masses with a noise level of 10 pm Hz-1/2 between 3 mHz and 30 mHz and also the test mass alignment with a noise level of <10 nrad Hz-1/2. An engineering model of the interferometer has been built and environmentally tested. Extensive functionality and performance tests were conducted. This paper reports on the successful test results.

UR - http://www.scopus.com/inward/record.url?scp=21244471096&partnerID=8YFLogxK

U2 - 10.1088/0264-9381/22/10/003

DO - 10.1088/0264-9381/22/10/003

M3 - Conference article

AN - SCOPUS:21244471096

VL - 22

SP - S149-S154

JO - Classical and quantum gravity

JF - Classical and quantum gravity

SN - 0264-9381

IS - 10

ER -