Subtraction of test mass angular noise in the LISA technology package interferometer

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • F. Guzmán Cervantes
  • F. Steier
  • G. Wanner
  • G. Heinzel
  • K. Danzmann

Organisationseinheiten

Externe Organisationen

  • Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)395-400
Seitenumfang6
FachzeitschriftApplied Physics B: Lasers and Optics
Jahrgang90
Ausgabenummer3-4
PublikationsstatusVeröffentlicht - März 2008

Abstract

When the position of a test mass in one dimension is measured with picometer accuracy, angular alignment jitter inevitably couples noise into the measurement. We present recent sensitivity measurements of the LISA technology package interferometer with articulated mirrors as test masses, actuated by piezo-electric transducers. The required longitudinal displacement resolution of 9 pm/√Hz above 3 mHz has been demonstrated with an angular noise that corresponds to the expected for on-orbit operation. The excess noise contribution of this test mass jitter onto the sensitive displacement readout was completely subtracted by fitting the angular interferometric data streams to the longitudinal displacement measurement. Thus, this cross-coupling constitutes no limitation to the required performance of the LISA technology package interferometry.

ASJC Scopus Sachgebiete

Zitieren

Subtraction of test mass angular noise in the LISA technology package interferometer. / Guzmán Cervantes, F.; Steier, F.; Wanner, G. et al.
in: Applied Physics B: Lasers and Optics, Jahrgang 90, Nr. 3-4, 03.2008, S. 395-400.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Guzmán Cervantes, F, Steier, F, Wanner, G, Heinzel, G & Danzmann, K 2008, 'Subtraction of test mass angular noise in the LISA technology package interferometer', Applied Physics B: Lasers and Optics, Jg. 90, Nr. 3-4, S. 395-400. https://doi.org/10.1007/s00340-007-2923-0
Guzmán Cervantes F, Steier F, Wanner G, Heinzel G, Danzmann K. Subtraction of test mass angular noise in the LISA technology package interferometer. Applied Physics B: Lasers and Optics. 2008 Mär;90(3-4):395-400. doi: 10.1007/s00340-007-2923-0
Guzmán Cervantes, F. ; Steier, F. ; Wanner, G. et al. / Subtraction of test mass angular noise in the LISA technology package interferometer. in: Applied Physics B: Lasers and Optics. 2008 ; Jahrgang 90, Nr. 3-4. S. 395-400.
Download
@article{b22683cfb8ae447d96ece0897c8150f7,
title = "Subtraction of test mass angular noise in the LISA technology package interferometer",
abstract = "When the position of a test mass in one dimension is measured with picometer accuracy, angular alignment jitter inevitably couples noise into the measurement. We present recent sensitivity measurements of the LISA technology package interferometer with articulated mirrors as test masses, actuated by piezo-electric transducers. The required longitudinal displacement resolution of 9 pm/√Hz above 3 mHz has been demonstrated with an angular noise that corresponds to the expected for on-orbit operation. The excess noise contribution of this test mass jitter onto the sensitive displacement readout was completely subtracted by fitting the angular interferometric data streams to the longitudinal displacement measurement. Thus, this cross-coupling constitutes no limitation to the required performance of the LISA technology package interferometry.",
author = "{Guzm{\'a}n Cervantes}, F. and F. Steier and G. Wanner and G. Heinzel and K. Danzmann",
year = "2008",
month = mar,
doi = "10.1007/s00340-007-2923-0",
language = "English",
volume = "90",
pages = "395--400",
journal = "Applied Physics B: Lasers and Optics",
issn = "0946-2171",
publisher = "Springer Verlag",
number = "3-4",

}

Download

TY - JOUR

T1 - Subtraction of test mass angular noise in the LISA technology package interferometer

AU - Guzmán Cervantes, F.

AU - Steier, F.

AU - Wanner, G.

AU - Heinzel, G.

AU - Danzmann, K.

PY - 2008/3

Y1 - 2008/3

N2 - When the position of a test mass in one dimension is measured with picometer accuracy, angular alignment jitter inevitably couples noise into the measurement. We present recent sensitivity measurements of the LISA technology package interferometer with articulated mirrors as test masses, actuated by piezo-electric transducers. The required longitudinal displacement resolution of 9 pm/√Hz above 3 mHz has been demonstrated with an angular noise that corresponds to the expected for on-orbit operation. The excess noise contribution of this test mass jitter onto the sensitive displacement readout was completely subtracted by fitting the angular interferometric data streams to the longitudinal displacement measurement. Thus, this cross-coupling constitutes no limitation to the required performance of the LISA technology package interferometry.

AB - When the position of a test mass in one dimension is measured with picometer accuracy, angular alignment jitter inevitably couples noise into the measurement. We present recent sensitivity measurements of the LISA technology package interferometer with articulated mirrors as test masses, actuated by piezo-electric transducers. The required longitudinal displacement resolution of 9 pm/√Hz above 3 mHz has been demonstrated with an angular noise that corresponds to the expected for on-orbit operation. The excess noise contribution of this test mass jitter onto the sensitive displacement readout was completely subtracted by fitting the angular interferometric data streams to the longitudinal displacement measurement. Thus, this cross-coupling constitutes no limitation to the required performance of the LISA technology package interferometry.

UR - http://www.scopus.com/inward/record.url?scp=40149083389&partnerID=8YFLogxK

U2 - 10.1007/s00340-007-2923-0

DO - 10.1007/s00340-007-2923-0

M3 - Article

AN - SCOPUS:40149083389

VL - 90

SP - 395

EP - 400

JO - Applied Physics B: Lasers and Optics

JF - Applied Physics B: Lasers and Optics

SN - 0946-2171

IS - 3-4

ER -