Statische und dynamische Axialdruckversuche an Vergrouteten Rohr-in-Rohr-Verbindungen mit verschiedenen Füllmaterialien

Publikation: Beitrag in nicht-wissenschaftlicher/populärwissenschaftlicher Zeitschrift/ZeitungBeitrag in Publikumszeitung/-zeitschriftTransfer

Autoren

  • Peter Schaumann
  • Christian Keindorf
  • Stephan Lochte-Holtgreven

Organisationseinheiten

Externe Organisationen

  • SKI Ingenieurges. mbH
Forschungs-netzwerk anzeigen

Details

Titel in ÜbersetzungStatic and dynamic axial compression tests on grouted tube-in-tube connections with various grout materials
OriginalspracheDeutsch
Seiten719-728
Seitenumfang10
Band86
Ausgabenummer11
FachzeitschriftBAUTECHNIK
PublikationsstatusVeröffentlicht - 17 Nov. 2009

Abstract

This paper sum marises static and dynamic axial compression tests on small scale grouted joints for offshore wind energy converters. The connection is mostly used between driven monopiles and tower sections as tube-in-tube connection. The gap between the tubes is filled with grout materials. The test series comprises grouted joints with smooth and ribbed surfaces of the tubes which are loaded by axial compression. The ultimate and fatigue limit state of the connection can be increased with shear keys along the overlapped length of the tubes to get a ribbed contact surface to the grout. In this case the axial load is transferred by compression struts between the shear keys. The bearing capacity depends mainly on the compressive strength of the grout and the geometry of the shear keys. In addition to the experimental results an analytical design concept is presented within this paper for grouted joints with shear keys. With the analytical model the axial load capacity of the grouted joint can be determined under consideration of the compression struts and number of shear keys.

ASJC Scopus Sachgebiete

Zitieren

Statische und dynamische Axialdruckversuche an Vergrouteten Rohr-in-Rohr-Verbindungen mit verschiedenen Füllmaterialien. / Schaumann, Peter; Keindorf, Christian; Lochte-Holtgreven, Stephan.
in: BAUTECHNIK, Jahrgang 86, Nr. 11, 17.11.2009, S. 719-728.

Publikation: Beitrag in nicht-wissenschaftlicher/populärwissenschaftlicher Zeitschrift/ZeitungBeitrag in Publikumszeitung/-zeitschriftTransfer

Schaumann P, Keindorf C, Lochte-Holtgreven S. Statische und dynamische Axialdruckversuche an Vergrouteten Rohr-in-Rohr-Verbindungen mit verschiedenen Füllmaterialien. BAUTECHNIK. 2009 Nov 17;86(11):719-728. doi: 10.1002/bate.200910071
Schaumann, Peter ; Keindorf, Christian ; Lochte-Holtgreven, Stephan. / Statische und dynamische Axialdruckversuche an Vergrouteten Rohr-in-Rohr-Verbindungen mit verschiedenen Füllmaterialien. in: BAUTECHNIK. 2009 ; Jahrgang 86, Nr. 11. S. 719-728.
Download
@misc{dbbce4339499460eba7ca18ccf86aa3e,
title = "Statische und dynamische Axialdruckversuche an Vergrouteten Rohr-in-Rohr-Verbindungen mit verschiedenen F{\"u}llmaterialien",
abstract = "This paper sum marises static and dynamic axial compression tests on small scale grouted joints for offshore wind energy converters. The connection is mostly used between driven monopiles and tower sections as tube-in-tube connection. The gap between the tubes is filled with grout materials. The test series comprises grouted joints with smooth and ribbed surfaces of the tubes which are loaded by axial compression. The ultimate and fatigue limit state of the connection can be increased with shear keys along the overlapped length of the tubes to get a ribbed contact surface to the grout. In this case the axial load is transferred by compression struts between the shear keys. The bearing capacity depends mainly on the compressive strength of the grout and the geometry of the shear keys. In addition to the experimental results an analytical design concept is presented within this paper for grouted joints with shear keys. With the analytical model the axial load capacity of the grouted joint can be determined under consideration of the compression struts and number of shear keys.",
author = "Peter Schaumann and Christian Keindorf and Stephan Lochte-Holtgreven",
year = "2009",
month = nov,
day = "17",
doi = "10.1002/bate.200910071",
language = "Deutsch",
volume = "86",
pages = "719--728",
journal = "BAUTECHNIK",
issn = "0932-8351",
publisher = "Wiley-Blackwell",

}

Download

TY - GEN

T1 - Statische und dynamische Axialdruckversuche an Vergrouteten Rohr-in-Rohr-Verbindungen mit verschiedenen Füllmaterialien

AU - Schaumann, Peter

AU - Keindorf, Christian

AU - Lochte-Holtgreven, Stephan

PY - 2009/11/17

Y1 - 2009/11/17

N2 - This paper sum marises static and dynamic axial compression tests on small scale grouted joints for offshore wind energy converters. The connection is mostly used between driven monopiles and tower sections as tube-in-tube connection. The gap between the tubes is filled with grout materials. The test series comprises grouted joints with smooth and ribbed surfaces of the tubes which are loaded by axial compression. The ultimate and fatigue limit state of the connection can be increased with shear keys along the overlapped length of the tubes to get a ribbed contact surface to the grout. In this case the axial load is transferred by compression struts between the shear keys. The bearing capacity depends mainly on the compressive strength of the grout and the geometry of the shear keys. In addition to the experimental results an analytical design concept is presented within this paper for grouted joints with shear keys. With the analytical model the axial load capacity of the grouted joint can be determined under consideration of the compression struts and number of shear keys.

AB - This paper sum marises static and dynamic axial compression tests on small scale grouted joints for offshore wind energy converters. The connection is mostly used between driven monopiles and tower sections as tube-in-tube connection. The gap between the tubes is filled with grout materials. The test series comprises grouted joints with smooth and ribbed surfaces of the tubes which are loaded by axial compression. The ultimate and fatigue limit state of the connection can be increased with shear keys along the overlapped length of the tubes to get a ribbed contact surface to the grout. In this case the axial load is transferred by compression struts between the shear keys. The bearing capacity depends mainly on the compressive strength of the grout and the geometry of the shear keys. In addition to the experimental results an analytical design concept is presented within this paper for grouted joints with shear keys. With the analytical model the axial load capacity of the grouted joint can be determined under consideration of the compression struts and number of shear keys.

UR - http://www.scopus.com/inward/record.url?scp=73649096914&partnerID=8YFLogxK

U2 - 10.1002/bate.200910071

DO - 10.1002/bate.200910071

M3 - Beitrag in Publikumszeitung/-zeitschrift

AN - SCOPUS:73649096914

VL - 86

SP - 719

EP - 728

JO - BAUTECHNIK

JF - BAUTECHNIK

SN - 0932-8351

ER -