Small volume coaxial discharge as precision testbed for 0D-models of XeCl lasers

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • W. Bötticher
  • H. Lück
  • S. Niesner
  • A. Schwabedissen

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)295-302
Seitenumfang8
FachzeitschriftApplied Physics B: Lasers and Optics
Jahrgang54
Ausgabenummer4
PublikationsstatusVeröffentlicht - 1992

Abstract

In order to check the predictions of 0D-models experimentally, a small coaxial discharge configuration for the generation of homogeneous high pressure glow discharges (diameter 11 mm, length 20 mm) in rare gas halogen excimer laser gas mixtures under accurately controlled conditions has been developed. It uses X-ray preionization and a special pulse-forming network (PFN) delivering fast rising (8 ns) single square pulses (U 05 kV; I00 A; prop00 ns). Discharge current and voltage are measured precisely by a capacitive voltage divider and a shunt integrated into the discharge chamber. All circuit data needed for the model calculations have been evaluated. Interferometric and spectroscopic diagnostics of the bulk of the discharge and of the cathode sheath have been performed. First results for Ne/Xe/HCl mixtures are compared with model calculations.

Zitieren

Small volume coaxial discharge as precision testbed for 0D-models of XeCl lasers. / Bötticher, W.; Lück, H.; Niesner, S. et al.
in: Applied Physics B: Lasers and Optics, Jahrgang 54, Nr. 4, 1992, S. 295-302.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Bötticher W, Lück H, Niesner S, Schwabedissen A. Small volume coaxial discharge as precision testbed for 0D-models of XeCl lasers. Applied Physics B: Lasers and Optics. 1992;54(4):295-302. doi: 10.1007/BF00325195
Bötticher, W. ; Lück, H. ; Niesner, S. et al. / Small volume coaxial discharge as precision testbed for 0D-models of XeCl lasers. in: Applied Physics B: Lasers and Optics. 1992 ; Jahrgang 54, Nr. 4. S. 295-302.
Download
@article{385a57b043e4478d9f6d762ed7612404,
title = "Small volume coaxial discharge as precision testbed for 0D-models of XeCl lasers",
abstract = "In order to check the predictions of 0D-models experimentally, a small coaxial discharge configuration for the generation of homogeneous high pressure glow discharges (diameter 11 mm, length 20 mm) in rare gas halogen excimer laser gas mixtures under accurately controlled conditions has been developed. It uses X-ray preionization and a special pulse-forming network (PFN) delivering fast rising (8 ns) single square pulses (U 05 kV; I00 A; prop00 ns). Discharge current and voltage are measured precisely by a capacitive voltage divider and a shunt integrated into the discharge chamber. All circuit data needed for the model calculations have been evaluated. Interferometric and spectroscopic diagnostics of the bulk of the discharge and of the cathode sheath have been performed. First results for Ne/Xe/HCl mixtures are compared with model calculations.",
author = "W. B{\"o}tticher and H. L{\"u}ck and S. Niesner and A. Schwabedissen",
year = "1992",
doi = "10.1007/BF00325195",
language = "English",
volume = "54",
pages = "295--302",
journal = "Applied Physics B: Lasers and Optics",
issn = "0946-2171",
publisher = "Springer Verlag",
number = "4",

}

Download

TY - JOUR

T1 - Small volume coaxial discharge as precision testbed for 0D-models of XeCl lasers

AU - Bötticher, W.

AU - Lück, H.

AU - Niesner, S.

AU - Schwabedissen, A.

PY - 1992

Y1 - 1992

N2 - In order to check the predictions of 0D-models experimentally, a small coaxial discharge configuration for the generation of homogeneous high pressure glow discharges (diameter 11 mm, length 20 mm) in rare gas halogen excimer laser gas mixtures under accurately controlled conditions has been developed. It uses X-ray preionization and a special pulse-forming network (PFN) delivering fast rising (8 ns) single square pulses (U 05 kV; I00 A; prop00 ns). Discharge current and voltage are measured precisely by a capacitive voltage divider and a shunt integrated into the discharge chamber. All circuit data needed for the model calculations have been evaluated. Interferometric and spectroscopic diagnostics of the bulk of the discharge and of the cathode sheath have been performed. First results for Ne/Xe/HCl mixtures are compared with model calculations.

AB - In order to check the predictions of 0D-models experimentally, a small coaxial discharge configuration for the generation of homogeneous high pressure glow discharges (diameter 11 mm, length 20 mm) in rare gas halogen excimer laser gas mixtures under accurately controlled conditions has been developed. It uses X-ray preionization and a special pulse-forming network (PFN) delivering fast rising (8 ns) single square pulses (U 05 kV; I00 A; prop00 ns). Discharge current and voltage are measured precisely by a capacitive voltage divider and a shunt integrated into the discharge chamber. All circuit data needed for the model calculations have been evaluated. Interferometric and spectroscopic diagnostics of the bulk of the discharge and of the cathode sheath have been performed. First results for Ne/Xe/HCl mixtures are compared with model calculations.

U2 - 10.1007/BF00325195

DO - 10.1007/BF00325195

M3 - Article

VL - 54

SP - 295

EP - 302

JO - Applied Physics B: Lasers and Optics

JF - Applied Physics B: Lasers and Optics

SN - 0946-2171

IS - 4

ER -