Simultaneous detection of benzene and toluene using a pulsed ion mobility spectrometer

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Organisationseinheiten

Externe Organisationen

  • German University in Cairo
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)106-110
Seitenumfang5
FachzeitschriftSensors and Actuators, B: Chemical
Jahrgang188
PublikationsstatusVeröffentlicht - 17 Juli 2013

Abstract

Ion mobility spectrometry (IMS) is a well known method for fast trace gas detection in air. Having simple instrumentation, IMS is especially suited when portability and highest sensitivity are required. However, due to competing chemical ionization processes in the reaction region of IMS, it can be difficult or even impossible to detect small amounts of certain substances in a complex mixture. A prominent example is the detection of low benzene concentrations in the presence of higher toluene concentrations. In this paper we present experimental results of simultaneous toluene and benzene detection by using a pulsed electron source for ionization and demonstrate how this can help to overcome the major issue of atmospheric pressure chemical ionization (APCI).

ASJC Scopus Sachgebiete

Zitieren

Simultaneous detection of benzene and toluene using a pulsed ion mobility spectrometer. / Zimmermann, Stefan; Gunzer, Frank.
in: Sensors and Actuators, B: Chemical, Jahrgang 188, 17.07.2013, S. 106-110.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{6b9893d1d3964dd3bac9bc32f73c609e,
title = "Simultaneous detection of benzene and toluene using a pulsed ion mobility spectrometer",
abstract = "Ion mobility spectrometry (IMS) is a well known method for fast trace gas detection in air. Having simple instrumentation, IMS is especially suited when portability and highest sensitivity are required. However, due to competing chemical ionization processes in the reaction region of IMS, it can be difficult or even impossible to detect small amounts of certain substances in a complex mixture. A prominent example is the detection of low benzene concentrations in the presence of higher toluene concentrations. In this paper we present experimental results of simultaneous toluene and benzene detection by using a pulsed electron source for ionization and demonstrate how this can help to overcome the major issue of atmospheric pressure chemical ionization (APCI).",
keywords = "Benzene, Ion mobility spectrometry, Non-radioactive electron sources, Pulsed electron beam ionization, Toluene",
author = "Stefan Zimmermann and Frank Gunzer",
year = "2013",
month = jul,
day = "17",
doi = "10.1016/j.snb.2013.06.079",
language = "English",
volume = "188",
pages = "106--110",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",

}

Download

TY - JOUR

T1 - Simultaneous detection of benzene and toluene using a pulsed ion mobility spectrometer

AU - Zimmermann, Stefan

AU - Gunzer, Frank

PY - 2013/7/17

Y1 - 2013/7/17

N2 - Ion mobility spectrometry (IMS) is a well known method for fast trace gas detection in air. Having simple instrumentation, IMS is especially suited when portability and highest sensitivity are required. However, due to competing chemical ionization processes in the reaction region of IMS, it can be difficult or even impossible to detect small amounts of certain substances in a complex mixture. A prominent example is the detection of low benzene concentrations in the presence of higher toluene concentrations. In this paper we present experimental results of simultaneous toluene and benzene detection by using a pulsed electron source for ionization and demonstrate how this can help to overcome the major issue of atmospheric pressure chemical ionization (APCI).

AB - Ion mobility spectrometry (IMS) is a well known method for fast trace gas detection in air. Having simple instrumentation, IMS is especially suited when portability and highest sensitivity are required. However, due to competing chemical ionization processes in the reaction region of IMS, it can be difficult or even impossible to detect small amounts of certain substances in a complex mixture. A prominent example is the detection of low benzene concentrations in the presence of higher toluene concentrations. In this paper we present experimental results of simultaneous toluene and benzene detection by using a pulsed electron source for ionization and demonstrate how this can help to overcome the major issue of atmospheric pressure chemical ionization (APCI).

KW - Benzene

KW - Ion mobility spectrometry

KW - Non-radioactive electron sources

KW - Pulsed electron beam ionization

KW - Toluene

UR - http://www.scopus.com/inward/record.url?scp=84881296061&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2013.06.079

DO - 10.1016/j.snb.2013.06.079

M3 - Article

AN - SCOPUS:84881296061

VL - 188

SP - 106

EP - 110

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

ER -