Shear bond strength between dental adhesive systems and an experimental niobium-based implant material

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Organisationseinheiten

Externe Organisationen

  • Medizinische Hochschule Hannover (MHH)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer65
FachzeitschriftJournal of Materials Science: Materials in Medicine
Jahrgang35
Ausgabenummer1
PublikationsstatusVeröffentlicht - 16 Okt. 2024

Abstract

This study aimed to investigate adhesive shear bond strength (SBS) on an ultrafine-grained niobium alloy (UFG-Nb) that is a potential dental implant material. SBS of three adhesive systems combined with three composites to UFG-Nb was compared to corresponding SBS to Ti-6Al-4V and to zirconia. Specimens of the substrates UFG-Nb, Ti-6Al-4V and zirconia with plane surfaces were sandblasted with Al2O3, cleaned and dried. Three adhesive systems (Futurabond U, Futurabond M +, Futurabond M + DCA; all VOCO GmbH, Cuxhaven, Germany) were applied each on specimens of each substrate and light cured. One composite (BifixSE, BifixQM, GrandioSO; all VOCO GmbH) was applied and light cured resulting in 27 groups (n = 10) for all substrate-adhesive-composite-combinations. SBS was measured after 24 h of storage. To simulate aging equally prepared specimens underwent 5000 thermocycles before SBS measurement. There was no significant difference in SBS within the non-aged groups. Among the artificially aged groups, GrandioSO-groups showed a greater variance of SBS than the other composites. All significant differences of corresponding UFG-Nb-, Ti-6Al-4V- and zirconia-groups with same adhesive-composite-combination (ACC) were observed between UFG-Nb and zirconia or Ti-6Al-4V and zirconia but never between the two metallic substrates. The similarity between these materials might show in their adhesive bonding behavior. As there were no differences comparing corresponding groups prior to and after artificial aging, it can be concluded that aging does not affect SBS to UFG-Nb, Ti-6Al-4V and zirconia using the tested ACCs. Adhesive bonding of established ACCs to UFG-Nb is possible resulting in SBS comparable to those on Ti-6Al-4V and zirconia surfaces. Graphical Abstract: (Figure presented.)

ASJC Scopus Sachgebiete

Zitieren

Shear bond strength between dental adhesive systems and an experimental niobium-based implant material. / Brümmer, N.; Klose, C.; Schleich, J. T. et al.
in: Journal of Materials Science: Materials in Medicine, Jahrgang 35, Nr. 1, 65, 16.10.2024.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{eda33f0ee4cb433eb7d85d205511025e,
title = "Shear bond strength between dental adhesive systems and an experimental niobium-based implant material",
abstract = "This study aimed to investigate adhesive shear bond strength (SBS) on an ultrafine-grained niobium alloy (UFG-Nb) that is a potential dental implant material. SBS of three adhesive systems combined with three composites to UFG-Nb was compared to corresponding SBS to Ti-6Al-4V and to zirconia. Specimens of the substrates UFG-Nb, Ti-6Al-4V and zirconia with plane surfaces were sandblasted with Al2O3, cleaned and dried. Three adhesive systems (Futurabond U, Futurabond M +, Futurabond M + DCA; all VOCO GmbH, Cuxhaven, Germany) were applied each on specimens of each substrate and light cured. One composite (BifixSE, BifixQM, GrandioSO; all VOCO GmbH) was applied and light cured resulting in 27 groups (n = 10) for all substrate-adhesive-composite-combinations. SBS was measured after 24 h of storage. To simulate aging equally prepared specimens underwent 5000 thermocycles before SBS measurement. There was no significant difference in SBS within the non-aged groups. Among the artificially aged groups, GrandioSO-groups showed a greater variance of SBS than the other composites. All significant differences of corresponding UFG-Nb-, Ti-6Al-4V- and zirconia-groups with same adhesive-composite-combination (ACC) were observed between UFG-Nb and zirconia or Ti-6Al-4V and zirconia but never between the two metallic substrates. The similarity between these materials might show in their adhesive bonding behavior. As there were no differences comparing corresponding groups prior to and after artificial aging, it can be concluded that aging does not affect SBS to UFG-Nb, Ti-6Al-4V and zirconia using the tested ACCs. Adhesive bonding of established ACCs to UFG-Nb is possible resulting in SBS comparable to those on Ti-6Al-4V and zirconia surfaces. Graphical Abstract: (Figure presented.)",
author = "N. Br{\"u}mmer and C. Klose and Schleich, {J. T.} and Maier, {H. J.} and M. Eisenburger and M. Stiesch and Pott, {P. C.}",
note = "Publisher Copyright: {\textcopyright} The Author(s) 2024.",
year = "2024",
month = oct,
day = "16",
doi = "10.1007/s10856-024-06834-7",
language = "English",
volume = "35",
journal = "Journal of Materials Science: Materials in Medicine",
issn = "0957-4530",
publisher = "Springer Netherlands",
number = "1",

}

Download

TY - JOUR

T1 - Shear bond strength between dental adhesive systems and an experimental niobium-based implant material

AU - Brümmer, N.

AU - Klose, C.

AU - Schleich, J. T.

AU - Maier, H. J.

AU - Eisenburger, M.

AU - Stiesch, M.

AU - Pott, P. C.

N1 - Publisher Copyright: © The Author(s) 2024.

PY - 2024/10/16

Y1 - 2024/10/16

N2 - This study aimed to investigate adhesive shear bond strength (SBS) on an ultrafine-grained niobium alloy (UFG-Nb) that is a potential dental implant material. SBS of three adhesive systems combined with three composites to UFG-Nb was compared to corresponding SBS to Ti-6Al-4V and to zirconia. Specimens of the substrates UFG-Nb, Ti-6Al-4V and zirconia with plane surfaces were sandblasted with Al2O3, cleaned and dried. Three adhesive systems (Futurabond U, Futurabond M +, Futurabond M + DCA; all VOCO GmbH, Cuxhaven, Germany) were applied each on specimens of each substrate and light cured. One composite (BifixSE, BifixQM, GrandioSO; all VOCO GmbH) was applied and light cured resulting in 27 groups (n = 10) for all substrate-adhesive-composite-combinations. SBS was measured after 24 h of storage. To simulate aging equally prepared specimens underwent 5000 thermocycles before SBS measurement. There was no significant difference in SBS within the non-aged groups. Among the artificially aged groups, GrandioSO-groups showed a greater variance of SBS than the other composites. All significant differences of corresponding UFG-Nb-, Ti-6Al-4V- and zirconia-groups with same adhesive-composite-combination (ACC) were observed between UFG-Nb and zirconia or Ti-6Al-4V and zirconia but never between the two metallic substrates. The similarity between these materials might show in their adhesive bonding behavior. As there were no differences comparing corresponding groups prior to and after artificial aging, it can be concluded that aging does not affect SBS to UFG-Nb, Ti-6Al-4V and zirconia using the tested ACCs. Adhesive bonding of established ACCs to UFG-Nb is possible resulting in SBS comparable to those on Ti-6Al-4V and zirconia surfaces. Graphical Abstract: (Figure presented.)

AB - This study aimed to investigate adhesive shear bond strength (SBS) on an ultrafine-grained niobium alloy (UFG-Nb) that is a potential dental implant material. SBS of three adhesive systems combined with three composites to UFG-Nb was compared to corresponding SBS to Ti-6Al-4V and to zirconia. Specimens of the substrates UFG-Nb, Ti-6Al-4V and zirconia with plane surfaces were sandblasted with Al2O3, cleaned and dried. Three adhesive systems (Futurabond U, Futurabond M +, Futurabond M + DCA; all VOCO GmbH, Cuxhaven, Germany) were applied each on specimens of each substrate and light cured. One composite (BifixSE, BifixQM, GrandioSO; all VOCO GmbH) was applied and light cured resulting in 27 groups (n = 10) for all substrate-adhesive-composite-combinations. SBS was measured after 24 h of storage. To simulate aging equally prepared specimens underwent 5000 thermocycles before SBS measurement. There was no significant difference in SBS within the non-aged groups. Among the artificially aged groups, GrandioSO-groups showed a greater variance of SBS than the other composites. All significant differences of corresponding UFG-Nb-, Ti-6Al-4V- and zirconia-groups with same adhesive-composite-combination (ACC) were observed between UFG-Nb and zirconia or Ti-6Al-4V and zirconia but never between the two metallic substrates. The similarity between these materials might show in their adhesive bonding behavior. As there were no differences comparing corresponding groups prior to and after artificial aging, it can be concluded that aging does not affect SBS to UFG-Nb, Ti-6Al-4V and zirconia using the tested ACCs. Adhesive bonding of established ACCs to UFG-Nb is possible resulting in SBS comparable to those on Ti-6Al-4V and zirconia surfaces. Graphical Abstract: (Figure presented.)

UR - http://www.scopus.com/inward/record.url?scp=85206514997&partnerID=8YFLogxK

U2 - 10.1007/s10856-024-06834-7

DO - 10.1007/s10856-024-06834-7

M3 - Article

C2 - 39412679

AN - SCOPUS:85206514997

VL - 35

JO - Journal of Materials Science: Materials in Medicine

JF - Journal of Materials Science: Materials in Medicine

SN - 0957-4530

IS - 1

M1 - 65

ER -

Von denselben Autoren