Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 78-94 |
Seitenumfang | 17 |
Fachzeitschrift | Computer-Aided Civil and Infrastructure Engineering |
Jahrgang | 18 |
Ausgabenummer | 1 |
Publikationsstatus | Veröffentlicht - 20 Jan. 2003 |
Abstract
Existing experimental results clearly demonstrate that the structural use of conventional, that is, "passive," high-performance fiber reinforced concretes (HPFRCs) results in excellent seismic performance. By combining shape memory alloy (SMA) fibers with conventional HPFRCs, self-actuating HPFRCs were recently developed. This paper explores a novel way of using such self-actuating SMA-based HPFRCs to develop more seismically resistant and cost-effective, auto-adaptive frame buildings. A numerical investigation on the use of self-actuating HPFRCs in highly energy absorbing, replaceable, "fuse" zones is presented first. Resulting SMA-HPFRCs "fuses" can adjust their response to the level of seismic overload. A brief discussion of the possible use of such self-actuating "fuses" in auto-adaptive structures is also provided. While in an actual auto-adaptive structure "triggering" of the desired self-actuating HPFRC fuse behavior will require the use of "sensing" and control elements, this paper focuses only on the behavior of SMA-HPFRC fuses and their effect on the overall structural response.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Tief- und Ingenieurbau
- Informatik (insg.)
- Angewandte Informatik
- Informatik (insg.)
- Computergrafik und computergestütztes Design
- Informatik (insg.)
- Theoretische Informatik und Mathematik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Computer-Aided Civil and Infrastructure Engineering, Jahrgang 18, Nr. 1, 20.01.2003, S. 78-94.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Self-actuating SMA-HPFRC fuses for auto-adaptive composite structures
AU - Krstulovic-Opara, N.
AU - Nau, J.
AU - Wriggers, Peter
AU - Krstulovic-Opara, L.
PY - 2003/1/20
Y1 - 2003/1/20
N2 - Existing experimental results clearly demonstrate that the structural use of conventional, that is, "passive," high-performance fiber reinforced concretes (HPFRCs) results in excellent seismic performance. By combining shape memory alloy (SMA) fibers with conventional HPFRCs, self-actuating HPFRCs were recently developed. This paper explores a novel way of using such self-actuating SMA-based HPFRCs to develop more seismically resistant and cost-effective, auto-adaptive frame buildings. A numerical investigation on the use of self-actuating HPFRCs in highly energy absorbing, replaceable, "fuse" zones is presented first. Resulting SMA-HPFRCs "fuses" can adjust their response to the level of seismic overload. A brief discussion of the possible use of such self-actuating "fuses" in auto-adaptive structures is also provided. While in an actual auto-adaptive structure "triggering" of the desired self-actuating HPFRC fuse behavior will require the use of "sensing" and control elements, this paper focuses only on the behavior of SMA-HPFRC fuses and their effect on the overall structural response.
AB - Existing experimental results clearly demonstrate that the structural use of conventional, that is, "passive," high-performance fiber reinforced concretes (HPFRCs) results in excellent seismic performance. By combining shape memory alloy (SMA) fibers with conventional HPFRCs, self-actuating HPFRCs were recently developed. This paper explores a novel way of using such self-actuating SMA-based HPFRCs to develop more seismically resistant and cost-effective, auto-adaptive frame buildings. A numerical investigation on the use of self-actuating HPFRCs in highly energy absorbing, replaceable, "fuse" zones is presented first. Resulting SMA-HPFRCs "fuses" can adjust their response to the level of seismic overload. A brief discussion of the possible use of such self-actuating "fuses" in auto-adaptive structures is also provided. While in an actual auto-adaptive structure "triggering" of the desired self-actuating HPFRC fuse behavior will require the use of "sensing" and control elements, this paper focuses only on the behavior of SMA-HPFRC fuses and their effect on the overall structural response.
UR - http://www.scopus.com/inward/record.url?scp=0037217337&partnerID=8YFLogxK
U2 - 10.1111/1467-8667.t01-1-00301
DO - 10.1111/1467-8667.t01-1-00301
M3 - Article
AN - SCOPUS:0037217337
VL - 18
SP - 78
EP - 94
JO - Computer-Aided Civil and Infrastructure Engineering
JF - Computer-Aided Civil and Infrastructure Engineering
SN - 1093-9687
IS - 1
ER -