Selection of the frequency range for high-voltage on-site testing of extruded insulation cable systems

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • Ernst Gockenbach
  • Wolfgang Hauschild

Externe Organisationen

  • HIGHVOLT Prüftechnik Dresden GmbH
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)11-16
Seitenumfang6
FachzeitschriftIEEE Electrical Insulation Magazine
Jahrgang16
Ausgabenummer6
PublikationsstatusVeröffentlicht - Nov. 2000

Abstract

An overview is given on the factors to be considered for the selection of a proper frequency range for high-voltage ac (HVAC) on-site testing of extruded insulation cable systems. This is done from the viewpoint of the breakdown mechanism of the cable insulation, taking into consideration different types of typical insulation defects.

ASJC Scopus Sachgebiete

Zitieren

Selection of the frequency range for high-voltage on-site testing of extruded insulation cable systems. / Gockenbach, Ernst; Hauschild, Wolfgang.
in: IEEE Electrical Insulation Magazine, Jahrgang 16, Nr. 6, 11.2000, S. 11-16.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{cf8bfe46cdd94f0c9bf5b71e6955868c,
title = "Selection of the frequency range for high-voltage on-site testing of extruded insulation cable systems",
abstract = "An overview is given on the factors to be considered for the selection of a proper frequency range for high-voltage ac (HVAC) on-site testing of extruded insulation cable systems. This is done from the viewpoint of the breakdown mechanism of the cable insulation, taking into consideration different types of typical insulation defects.",
author = "Ernst Gockenbach and Wolfgang Hauschild",
note = "Copyright: Copyright 2004 Elsevier Science B.V., Amsterdam. All rights reserved.",
year = "2000",
month = nov,
doi = "10.1109/57.887600",
language = "English",
volume = "16",
pages = "11--16",
journal = "IEEE Electrical Insulation Magazine",
issn = "0883-7554",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
number = "6",

}

Download

TY - JOUR

T1 - Selection of the frequency range for high-voltage on-site testing of extruded insulation cable systems

AU - Gockenbach, Ernst

AU - Hauschild, Wolfgang

N1 - Copyright: Copyright 2004 Elsevier Science B.V., Amsterdam. All rights reserved.

PY - 2000/11

Y1 - 2000/11

N2 - An overview is given on the factors to be considered for the selection of a proper frequency range for high-voltage ac (HVAC) on-site testing of extruded insulation cable systems. This is done from the viewpoint of the breakdown mechanism of the cable insulation, taking into consideration different types of typical insulation defects.

AB - An overview is given on the factors to be considered for the selection of a proper frequency range for high-voltage ac (HVAC) on-site testing of extruded insulation cable systems. This is done from the viewpoint of the breakdown mechanism of the cable insulation, taking into consideration different types of typical insulation defects.

UR - http://www.scopus.com/inward/record.url?scp=0034316011&partnerID=8YFLogxK

U2 - 10.1109/57.887600

DO - 10.1109/57.887600

M3 - Article

AN - SCOPUS:0034316011

VL - 16

SP - 11

EP - 16

JO - IEEE Electrical Insulation Magazine

JF - IEEE Electrical Insulation Magazine

SN - 0883-7554

IS - 6

ER -