Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading

Publikation: KonferenzbeitragPaperForschungPeer-Review

Autoren

  • Corinne Otto
  • Ludger Lohaus
  • Dario Cotardo

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten1792-1801
Seitenumfang10
PublikationsstatusVeröffentlicht - Okt. 2018
Veranstaltung5th fib Congress, FIB 2018 - Melbourne, Australien
Dauer: 7 Okt. 201811 Okt. 2018

Konferenz

Konferenz5th fib Congress, FIB 2018
Land/GebietAustralien
OrtMelbourne
Zeitraum7 Okt. 201811 Okt. 2018

Abstract

High-strength grouts are commonly used in the wind energy industry, where they are exposed to high cyclic loading. However, so far, concerning the specific fatigue behaviour of these grouts, any research is hardly available. Latest scientific results (e.g. Elsmeier (2018)) show that there is a divergent fatigue behaviour of high-strength grout compared to high-strength concrete. Above this, there are still considerable uncertainties regarding the impact of composition parameters like the paste volume or the maximum grain size dG on the fatigue resistance of high-strength grout. In particular, the interfacial transition zone and a tighter pore system in combination with the moisture content of the specimen seem to have an influence on the fatigue behaviour of high-strength grout. In fatigue tests with cement paste, a higher number of load cycles and significantly higher temperatures were reached. During some tests, drops of condensing water could be observed on the cold pressure plates of the testing machine. This could be an indicator of water vapour pressure, which might have led to a premature failure. Furthermore, some correlations could be shown between the increase in temperature during testing and the influence of the loading frequency fP, the maximum grain size dG and the paste volume.

ASJC Scopus Sachgebiete

Zitieren

Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading. / Otto, Corinne; Lohaus, Ludger; Cotardo, Dario.
2018. 1792-1801 Beitrag in 5th fib Congress, FIB 2018, Melbourne, Australien.

Publikation: KonferenzbeitragPaperForschungPeer-Review

Otto, C, Lohaus, L & Cotardo, D 2018, 'Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading', Beitrag in 5th fib Congress, FIB 2018, Melbourne, Australien, 7 Okt. 2018 - 11 Okt. 2018 S. 1792-1801.
Otto, C., Lohaus, L., & Cotardo, D. (2018). Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading. 1792-1801. Beitrag in 5th fib Congress, FIB 2018, Melbourne, Australien.
Otto C, Lohaus L, Cotardo D. Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading. 2018. Beitrag in 5th fib Congress, FIB 2018, Melbourne, Australien.
Otto, Corinne ; Lohaus, Ludger ; Cotardo, Dario. / Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading. Beitrag in 5th fib Congress, FIB 2018, Melbourne, Australien.10 S.
Download
@conference{e21bedac0de34d39b5543b026e4cc698,
title = "Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading",
abstract = "High-strength grouts are commonly used in the wind energy industry, where they are exposed to high cyclic loading. However, so far, concerning the specific fatigue behaviour of these grouts, any research is hardly available. Latest scientific results (e.g. Elsmeier (2018)) show that there is a divergent fatigue behaviour of high-strength grout compared to high-strength concrete. Above this, there are still considerable uncertainties regarding the impact of composition parameters like the paste volume or the maximum grain size dG on the fatigue resistance of high-strength grout. In particular, the interfacial transition zone and a tighter pore system in combination with the moisture content of the specimen seem to have an influence on the fatigue behaviour of high-strength grout. In fatigue tests with cement paste, a higher number of load cycles and significantly higher temperatures were reached. During some tests, drops of condensing water could be observed on the cold pressure plates of the testing machine. This could be an indicator of water vapour pressure, which might have led to a premature failure. Furthermore, some correlations could be shown between the increase in temperature during testing and the influence of the loading frequency fP, the maximum grain size dG and the paste volume.",
keywords = "Fatigue behaviour, Heating-rate, High-strength grout, Loading frequency fP, Maximum grain size d, Warming of specimen, Maximum grain size dG",
author = "Corinne Otto and Ludger Lohaus and Dario Cotardo",
note = "Funding Information: The research project is supported by the German Research Foundation (DFG).The authors would like to express their gratitude for the financial support. Publisher Copyright: {\textcopyright} 2019 by the fib. All rights reserved. Copyright: Copyright 2020 Elsevier B.V., All rights reserved.; 5th fib Congress, FIB 2018 ; Conference date: 07-10-2018 Through 11-10-2018",
year = "2018",
month = oct,
language = "English",
pages = "1792--1801",

}

Download

TY - CONF

T1 - Premature failure of high-strength grout in fatigue tests due to the warming of specimen during cyclic loading

AU - Otto, Corinne

AU - Lohaus, Ludger

AU - Cotardo, Dario

N1 - Funding Information: The research project is supported by the German Research Foundation (DFG).The authors would like to express their gratitude for the financial support. Publisher Copyright: © 2019 by the fib. All rights reserved. Copyright: Copyright 2020 Elsevier B.V., All rights reserved.

PY - 2018/10

Y1 - 2018/10

N2 - High-strength grouts are commonly used in the wind energy industry, where they are exposed to high cyclic loading. However, so far, concerning the specific fatigue behaviour of these grouts, any research is hardly available. Latest scientific results (e.g. Elsmeier (2018)) show that there is a divergent fatigue behaviour of high-strength grout compared to high-strength concrete. Above this, there are still considerable uncertainties regarding the impact of composition parameters like the paste volume or the maximum grain size dG on the fatigue resistance of high-strength grout. In particular, the interfacial transition zone and a tighter pore system in combination with the moisture content of the specimen seem to have an influence on the fatigue behaviour of high-strength grout. In fatigue tests with cement paste, a higher number of load cycles and significantly higher temperatures were reached. During some tests, drops of condensing water could be observed on the cold pressure plates of the testing machine. This could be an indicator of water vapour pressure, which might have led to a premature failure. Furthermore, some correlations could be shown between the increase in temperature during testing and the influence of the loading frequency fP, the maximum grain size dG and the paste volume.

AB - High-strength grouts are commonly used in the wind energy industry, where they are exposed to high cyclic loading. However, so far, concerning the specific fatigue behaviour of these grouts, any research is hardly available. Latest scientific results (e.g. Elsmeier (2018)) show that there is a divergent fatigue behaviour of high-strength grout compared to high-strength concrete. Above this, there are still considerable uncertainties regarding the impact of composition parameters like the paste volume or the maximum grain size dG on the fatigue resistance of high-strength grout. In particular, the interfacial transition zone and a tighter pore system in combination with the moisture content of the specimen seem to have an influence on the fatigue behaviour of high-strength grout. In fatigue tests with cement paste, a higher number of load cycles and significantly higher temperatures were reached. During some tests, drops of condensing water could be observed on the cold pressure plates of the testing machine. This could be an indicator of water vapour pressure, which might have led to a premature failure. Furthermore, some correlations could be shown between the increase in temperature during testing and the influence of the loading frequency fP, the maximum grain size dG and the paste volume.

KW - Fatigue behaviour

KW - Heating-rate

KW - High-strength grout

KW - Loading frequency fP

KW - Maximum grain size d

KW - Warming of specimen

KW - Maximum grain size dG

UR - http://www.scopus.com/inward/record.url?scp=85081085469&partnerID=8YFLogxK

M3 - Paper

SP - 1792

EP - 1801

T2 - 5th fib Congress, FIB 2018

Y2 - 7 October 2018 through 11 October 2018

ER -