Details
Originalsprache | Englisch |
---|---|
Fachzeitschrift | Physical Review A - Atomic, Molecular, and Optical Physics |
Jahrgang | 67 |
Ausgabenummer | 1 |
Publikationsstatus | Veröffentlicht - 30 Jan. 2003 |
Abstract
The lifetime of the metastable [Formula Presented] state of neon has been determined as [Formula Presented] [decay rate [Formula Presented] by measuring the decay in fluorescence of an ensemble of [Formula Presented] atoms trapped in a magneto-optical trap (MOT). Due to low background gas pressure [Formula Presented] and low relative excitation to the [Formula Presented] state (0.5 % excitation probability) only small corrections have to be included in the lifetime extrapolation. Together with a careful analysis of residual loss mechanisms in the MOT a lifetime determination to high precision is achieved.
ASJC Scopus Sachgebiete
- Physik und Astronomie (insg.)
- Atom- und Molekularphysik sowie Optik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Physical Review A - Atomic, Molecular, and Optical Physics, Jahrgang 67, Nr. 1, 30.01.2003.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Precision measurement of the metastable 3P2 lifetime of neon
AU - Zinner, Martin
AU - Spoden, Peter
AU - Kraemer, Tobias
AU - Birkl, Gerhard
AU - Ertmer, Wolfgang
PY - 2003/1/30
Y1 - 2003/1/30
N2 - The lifetime of the metastable [Formula Presented] state of neon has been determined as [Formula Presented] [decay rate [Formula Presented] by measuring the decay in fluorescence of an ensemble of [Formula Presented] atoms trapped in a magneto-optical trap (MOT). Due to low background gas pressure [Formula Presented] and low relative excitation to the [Formula Presented] state (0.5 % excitation probability) only small corrections have to be included in the lifetime extrapolation. Together with a careful analysis of residual loss mechanisms in the MOT a lifetime determination to high precision is achieved.
AB - The lifetime of the metastable [Formula Presented] state of neon has been determined as [Formula Presented] [decay rate [Formula Presented] by measuring the decay in fluorescence of an ensemble of [Formula Presented] atoms trapped in a magneto-optical trap (MOT). Due to low background gas pressure [Formula Presented] and low relative excitation to the [Formula Presented] state (0.5 % excitation probability) only small corrections have to be included in the lifetime extrapolation. Together with a careful analysis of residual loss mechanisms in the MOT a lifetime determination to high precision is achieved.
UR - http://www.scopus.com/inward/record.url?scp=84860466778&partnerID=8YFLogxK
U2 - 10.1103/PhysRevA.67.010501
DO - 10.1103/PhysRevA.67.010501
M3 - Article
AN - SCOPUS:84860466778
VL - 67
JO - Physical Review A - Atomic, Molecular, and Optical Physics
JF - Physical Review A - Atomic, Molecular, and Optical Physics
SN - 1050-2947
IS - 1
ER -