Performance of miniaturized atomic clocks in static laboratory and dynamic flight environments

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Organisationseinheiten

Externe Organisationen

  • Physikalisch-Technische Bundesanstalt (PTB)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer5
FachzeitschriftGPS solutions
Jahrgang25
Ausgabenummer1
Frühes Online-Datum13 Okt. 2020
PublikationsstatusVeröffentlicht - 1 Jan. 2021

Abstract

Miniaturized atomic clocks with high frequency stability as local oscillators in global navigation satellite system (GNSS) receivers promise to improve real-time kinematic applications. For a number of years, such oscillators are being investigated regarding their overall technical applicability, i.e., transportability, and performance in dynamic environments. The short-term frequency stability of these clocks is usually specified by the manufacturer, being valid for stationary applications. Since the performance of most oscillators is likely degraded in dynamic conditions, various oscillators are tested to find the limits of receiver clock modeling in dynamic cases and consequently derive adequate stochastic models to be used in navigation. We present the performance of three different oscillators (Microsemi MAC SA.35m, Spectratime LCR-900 and Stanford Research Systems SC10) for static and dynamic applications. For the static case, all three oscillators are characterized in terms of their frequency stability at Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The resulting Allan deviations agree well with the manufacturer's data. Furthermore, a flight experiment was conducted in order to evaluate the performance of the oscillators under dynamic conditions. Here, each oscillator is replacing the internal oscillator of a geodetic-grade GNSS receiver and the stability of the receiver clock biases is determined. The time and frequency offsets of the oscillators are characterized with regard to the flight dynamics recorded by a navigation-grade inertial measurement unit. The results of the experiment show that the frequency stability of each oscillator is degraded by about at least one order of magnitude compared to the static case. Also, the two quartz oscillators show a significant g-sensitivity resulting in frequency shifts of − 1.2 × 10−9 and + 1.5 × 10−9, respectively, while the rubidium clocks are less sensitive, thus enabling receiver clock modeling and strengthening of the navigation performance even in high dynamics.

ASJC Scopus Sachgebiete

Zitieren

Performance of miniaturized atomic clocks in static laboratory and dynamic flight environments. / Jain, Ankit; Krawinkel, Thomas; Schön, Steffen et al.
in: GPS solutions, Jahrgang 25, Nr. 1, 5, 01.01.2021.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Jain A, Krawinkel T, Schön S, Bauch A. Performance of miniaturized atomic clocks in static laboratory and dynamic flight environments. GPS solutions. 2021 Jan 1;25(1):5. Epub 2020 Okt 13. doi: 10.1007/s10291-020-01036-4
Download
@article{55c3963504284a9f80312afec7a6325d,
title = "Performance of miniaturized atomic clocks in static laboratory and dynamic flight environments",
abstract = "Miniaturized atomic clocks with high frequency stability as local oscillators in global navigation satellite system (GNSS) receivers promise to improve real-time kinematic applications. For a number of years, such oscillators are being investigated regarding their overall technical applicability, i.e., transportability, and performance in dynamic environments. The short-term frequency stability of these clocks is usually specified by the manufacturer, being valid for stationary applications. Since the performance of most oscillators is likely degraded in dynamic conditions, various oscillators are tested to find the limits of receiver clock modeling in dynamic cases and consequently derive adequate stochastic models to be used in navigation. We present the performance of three different oscillators (Microsemi MAC SA.35m, Spectratime LCR-900 and Stanford Research Systems SC10) for static and dynamic applications. For the static case, all three oscillators are characterized in terms of their frequency stability at Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The resulting Allan deviations agree well with the manufacturer's data. Furthermore, a flight experiment was conducted in order to evaluate the performance of the oscillators under dynamic conditions. Here, each oscillator is replacing the internal oscillator of a geodetic-grade GNSS receiver and the stability of the receiver clock biases is determined. The time and frequency offsets of the oscillators are characterized with regard to the flight dynamics recorded by a navigation-grade inertial measurement unit. The results of the experiment show that the frequency stability of each oscillator is degraded by about at least one order of magnitude compared to the static case. Also, the two quartz oscillators show a significant g-sensitivity resulting in frequency shifts of − 1.2 × 10−9 and + 1.5 × 10−9, respectively, while the rubidium clocks are less sensitive, thus enabling receiver clock modeling and strengthening of the navigation performance even in high dynamics.",
keywords = "Allan variance, Flight navigation, Frequency stability, GNSS, Miniaturized atomic clocks",
author = "Ankit Jain and Thomas Krawinkel and Steffen Sch{\"o}n and Andreas Bauch",
note = "Funding Information: This work has been funded by the German Federal Ministry for Economic Affairs and Energy following a resolution of the German Bundestag (Project Number: 50NA1705).",
year = "2021",
month = jan,
day = "1",
doi = "10.1007/s10291-020-01036-4",
language = "English",
volume = "25",
journal = "GPS solutions",
issn = "1080-5370",
publisher = "Springer Nature",
number = "1",

}

Download

TY - JOUR

T1 - Performance of miniaturized atomic clocks in static laboratory and dynamic flight environments

AU - Jain, Ankit

AU - Krawinkel, Thomas

AU - Schön, Steffen

AU - Bauch, Andreas

N1 - Funding Information: This work has been funded by the German Federal Ministry for Economic Affairs and Energy following a resolution of the German Bundestag (Project Number: 50NA1705).

PY - 2021/1/1

Y1 - 2021/1/1

N2 - Miniaturized atomic clocks with high frequency stability as local oscillators in global navigation satellite system (GNSS) receivers promise to improve real-time kinematic applications. For a number of years, such oscillators are being investigated regarding their overall technical applicability, i.e., transportability, and performance in dynamic environments. The short-term frequency stability of these clocks is usually specified by the manufacturer, being valid for stationary applications. Since the performance of most oscillators is likely degraded in dynamic conditions, various oscillators are tested to find the limits of receiver clock modeling in dynamic cases and consequently derive adequate stochastic models to be used in navigation. We present the performance of three different oscillators (Microsemi MAC SA.35m, Spectratime LCR-900 and Stanford Research Systems SC10) for static and dynamic applications. For the static case, all three oscillators are characterized in terms of their frequency stability at Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The resulting Allan deviations agree well with the manufacturer's data. Furthermore, a flight experiment was conducted in order to evaluate the performance of the oscillators under dynamic conditions. Here, each oscillator is replacing the internal oscillator of a geodetic-grade GNSS receiver and the stability of the receiver clock biases is determined. The time and frequency offsets of the oscillators are characterized with regard to the flight dynamics recorded by a navigation-grade inertial measurement unit. The results of the experiment show that the frequency stability of each oscillator is degraded by about at least one order of magnitude compared to the static case. Also, the two quartz oscillators show a significant g-sensitivity resulting in frequency shifts of − 1.2 × 10−9 and + 1.5 × 10−9, respectively, while the rubidium clocks are less sensitive, thus enabling receiver clock modeling and strengthening of the navigation performance even in high dynamics.

AB - Miniaturized atomic clocks with high frequency stability as local oscillators in global navigation satellite system (GNSS) receivers promise to improve real-time kinematic applications. For a number of years, such oscillators are being investigated regarding their overall technical applicability, i.e., transportability, and performance in dynamic environments. The short-term frequency stability of these clocks is usually specified by the manufacturer, being valid for stationary applications. Since the performance of most oscillators is likely degraded in dynamic conditions, various oscillators are tested to find the limits of receiver clock modeling in dynamic cases and consequently derive adequate stochastic models to be used in navigation. We present the performance of three different oscillators (Microsemi MAC SA.35m, Spectratime LCR-900 and Stanford Research Systems SC10) for static and dynamic applications. For the static case, all three oscillators are characterized in terms of their frequency stability at Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The resulting Allan deviations agree well with the manufacturer's data. Furthermore, a flight experiment was conducted in order to evaluate the performance of the oscillators under dynamic conditions. Here, each oscillator is replacing the internal oscillator of a geodetic-grade GNSS receiver and the stability of the receiver clock biases is determined. The time and frequency offsets of the oscillators are characterized with regard to the flight dynamics recorded by a navigation-grade inertial measurement unit. The results of the experiment show that the frequency stability of each oscillator is degraded by about at least one order of magnitude compared to the static case. Also, the two quartz oscillators show a significant g-sensitivity resulting in frequency shifts of − 1.2 × 10−9 and + 1.5 × 10−9, respectively, while the rubidium clocks are less sensitive, thus enabling receiver clock modeling and strengthening of the navigation performance even in high dynamics.

KW - Allan variance

KW - Flight navigation

KW - Frequency stability

KW - GNSS

KW - Miniaturized atomic clocks

UR - http://www.scopus.com/inward/record.url?scp=85092428806&partnerID=8YFLogxK

U2 - 10.1007/s10291-020-01036-4

DO - 10.1007/s10291-020-01036-4

M3 - Article

AN - SCOPUS:85092428806

VL - 25

JO - GPS solutions

JF - GPS solutions

SN - 1080-5370

IS - 1

M1 - 5

ER -

Von denselben Autoren