Performance of differently arranged double-tuned mass dampers for structural seismic response control including soil-structure interaction

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Externe Organisationen

  • Gumushane University
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer118841
Seitenumfang26
FachzeitschriftEngineering structures
Jahrgang319
Frühes Online-Datum29 Aug. 2024
PublikationsstatusVeröffentlicht - 15 Nov. 2024

Abstract

Reducing vibrations occurring in structures under environmental loads makes a significant contribution to the development of structural safety. Tuned mass dampers (TMD) are one of the systems commonly used to control structural vibrations. Since TMD is adjusted according to the dominant frequency of the structure, factors that may cause changes in the frequency of the structure can significantly reduce the effectiveness of TMD. One of the main factors that can cause changes in the frequency values of the structure is the interaction between the structure and the soil. To overcome this situation, it is recommended to apply control systems consisting of multiple TMDs (MTMD) to the main structure instead of a single TMD. MTMD systems are arranged in two different types, serial and parallel. In this paper, a methodology that considers the structure-soil interaction (SSI) is presented for the optimum design of control systems with different configurations placed on a main structure under the influence of ground motion. To research the SSI effects, the TMDs-structure coupled system is supported by rocking and swaying springs and the corresponding dashpots, and then the equations of motions of the structural system are derived. In the optimization process based on particle swarm optimization in the frequency domain, different soil types, configuration types, and mass ratios are considered. The efficiency of optimum TMDs arranged in series and parallel is also evaluated using near and far fault ground motions in the time domain. Numerical results show that if structures are constructed on soils with low shear wave velocities, ignoring SSI can significantly change the design parameters and effectiveness of the control system.

ASJC Scopus Sachgebiete

Zitieren

Performance of differently arranged double-tuned mass dampers for structural seismic response control including soil-structure interaction. / Araz, Onur; Elias, Said.
in: Engineering structures, Jahrgang 319, 118841, 15.11.2024.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{5bf0cd8c75a04c36b483f1b21fde7b70,
title = "Performance of differently arranged double-tuned mass dampers for structural seismic response control including soil-structure interaction",
abstract = "Reducing vibrations occurring in structures under environmental loads makes a significant contribution to the development of structural safety. Tuned mass dampers (TMD) are one of the systems commonly used to control structural vibrations. Since TMD is adjusted according to the dominant frequency of the structure, factors that may cause changes in the frequency of the structure can significantly reduce the effectiveness of TMD. One of the main factors that can cause changes in the frequency values of the structure is the interaction between the structure and the soil. To overcome this situation, it is recommended to apply control systems consisting of multiple TMDs (MTMD) to the main structure instead of a single TMD. MTMD systems are arranged in two different types, serial and parallel. In this paper, a methodology that considers the structure-soil interaction (SSI) is presented for the optimum design of control systems with different configurations placed on a main structure under the influence of ground motion. To research the SSI effects, the TMDs-structure coupled system is supported by rocking and swaying springs and the corresponding dashpots, and then the equations of motions of the structural system are derived. In the optimization process based on particle swarm optimization in the frequency domain, different soil types, configuration types, and mass ratios are considered. The efficiency of optimum TMDs arranged in series and parallel is also evaluated using near and far fault ground motions in the time domain. Numerical results show that if structures are constructed on soils with low shear wave velocities, ignoring SSI can significantly change the design parameters and effectiveness of the control system.",
keywords = "Seismic control, Soil structure interaction, Structural safety, Tuned mass dampers",
author = "Onur Araz and Said Elias",
note = "Publisher Copyright: {\textcopyright} 2024 Elsevier Ltd",
year = "2024",
month = nov,
day = "15",
doi = "10.1016/j.engstruct.2024.118841",
language = "English",
volume = "319",
journal = "Engineering structures",
issn = "0141-0296",
publisher = "Elsevier BV",

}

Download

TY - JOUR

T1 - Performance of differently arranged double-tuned mass dampers for structural seismic response control including soil-structure interaction

AU - Araz, Onur

AU - Elias, Said

N1 - Publisher Copyright: © 2024 Elsevier Ltd

PY - 2024/11/15

Y1 - 2024/11/15

N2 - Reducing vibrations occurring in structures under environmental loads makes a significant contribution to the development of structural safety. Tuned mass dampers (TMD) are one of the systems commonly used to control structural vibrations. Since TMD is adjusted according to the dominant frequency of the structure, factors that may cause changes in the frequency of the structure can significantly reduce the effectiveness of TMD. One of the main factors that can cause changes in the frequency values of the structure is the interaction between the structure and the soil. To overcome this situation, it is recommended to apply control systems consisting of multiple TMDs (MTMD) to the main structure instead of a single TMD. MTMD systems are arranged in two different types, serial and parallel. In this paper, a methodology that considers the structure-soil interaction (SSI) is presented for the optimum design of control systems with different configurations placed on a main structure under the influence of ground motion. To research the SSI effects, the TMDs-structure coupled system is supported by rocking and swaying springs and the corresponding dashpots, and then the equations of motions of the structural system are derived. In the optimization process based on particle swarm optimization in the frequency domain, different soil types, configuration types, and mass ratios are considered. The efficiency of optimum TMDs arranged in series and parallel is also evaluated using near and far fault ground motions in the time domain. Numerical results show that if structures are constructed on soils with low shear wave velocities, ignoring SSI can significantly change the design parameters and effectiveness of the control system.

AB - Reducing vibrations occurring in structures under environmental loads makes a significant contribution to the development of structural safety. Tuned mass dampers (TMD) are one of the systems commonly used to control structural vibrations. Since TMD is adjusted according to the dominant frequency of the structure, factors that may cause changes in the frequency of the structure can significantly reduce the effectiveness of TMD. One of the main factors that can cause changes in the frequency values of the structure is the interaction between the structure and the soil. To overcome this situation, it is recommended to apply control systems consisting of multiple TMDs (MTMD) to the main structure instead of a single TMD. MTMD systems are arranged in two different types, serial and parallel. In this paper, a methodology that considers the structure-soil interaction (SSI) is presented for the optimum design of control systems with different configurations placed on a main structure under the influence of ground motion. To research the SSI effects, the TMDs-structure coupled system is supported by rocking and swaying springs and the corresponding dashpots, and then the equations of motions of the structural system are derived. In the optimization process based on particle swarm optimization in the frequency domain, different soil types, configuration types, and mass ratios are considered. The efficiency of optimum TMDs arranged in series and parallel is also evaluated using near and far fault ground motions in the time domain. Numerical results show that if structures are constructed on soils with low shear wave velocities, ignoring SSI can significantly change the design parameters and effectiveness of the control system.

KW - Seismic control

KW - Soil structure interaction

KW - Structural safety

KW - Tuned mass dampers

UR - http://www.scopus.com/inward/record.url?scp=85202342512&partnerID=8YFLogxK

U2 - 10.1016/j.engstruct.2024.118841

DO - 10.1016/j.engstruct.2024.118841

M3 - Article

AN - SCOPUS:85202342512

VL - 319

JO - Engineering structures

JF - Engineering structures

SN - 0141-0296

M1 - 118841

ER -

Von denselben Autoren