Abstract

We present an optofluidic system based on electromagnetic manipulation of a ferrofluid to tune a liquid lens. Both studies of the dynamics of fluid transport and of the optical properties of the liquid lens have been carried out. Thermal and magnetic field simulations of the microcoil actuators are presented. Proof-of-principle experiments demonstrating the adaption of the focal length of the lens have been carried out. It is shown that the lens adaption proceeds in a reversible and reproducible manner, given that the ferrofluid plug moves with a speed below a specific threshold value. Furthermore, the time delay between the actuation and the deflection of the lens surface is studied.

ASJC Scopus Sachgebiete

Zitieren

Performance of an adaptive liquid microlens controlled by a microcoil actuator. / Schultheis, Thanin; Hoheisel, Dominik; Xiao, Wenjia et al.
in: Microfluidics and Nanofluidics, Jahrgang 13, Nr. 2, 07.03.2012, S. 299-308.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Schultheis, T, Hoheisel, D, Xiao, W, Spani-Molella, L, Reithmeier, E, Rissing, L & Hardt, S 2012, 'Performance of an adaptive liquid microlens controlled by a microcoil actuator', Microfluidics and Nanofluidics, Jg. 13, Nr. 2, S. 299-308. https://doi.org/10.1007/s10404-012-0961-3
Schultheis, T., Hoheisel, D., Xiao, W., Spani-Molella, L., Reithmeier, E., Rissing, L., & Hardt, S. (2012). Performance of an adaptive liquid microlens controlled by a microcoil actuator. Microfluidics and Nanofluidics, 13(2), 299-308. https://doi.org/10.1007/s10404-012-0961-3
Schultheis T, Hoheisel D, Xiao W, Spani-Molella L, Reithmeier E, Rissing L et al. Performance of an adaptive liquid microlens controlled by a microcoil actuator. Microfluidics and Nanofluidics. 2012 Mär 7;13(2):299-308. doi: 10.1007/s10404-012-0961-3
Schultheis, Thanin ; Hoheisel, Dominik ; Xiao, Wenjia et al. / Performance of an adaptive liquid microlens controlled by a microcoil actuator. in: Microfluidics and Nanofluidics. 2012 ; Jahrgang 13, Nr. 2. S. 299-308.
Download
@article{03895f30f022428cb5e65ed4dca8e997,
title = "Performance of an adaptive liquid microlens controlled by a microcoil actuator",
abstract = "We present an optofluidic system based on electromagnetic manipulation of a ferrofluid to tune a liquid lens. Both studies of the dynamics of fluid transport and of the optical properties of the liquid lens have been carried out. Thermal and magnetic field simulations of the microcoil actuators are presented. Proof-of-principle experiments demonstrating the adaption of the focal length of the lens have been carried out. It is shown that the lens adaption proceeds in a reversible and reproducible manner, given that the ferrofluid plug moves with a speed below a specific threshold value. Furthermore, the time delay between the actuation and the deflection of the lens surface is studied.",
keywords = "Keywords Ferrofluid, Liquid lens, Microactuator, Microchannel, Microcoil, Microfluidics, Microoptics, Optical liquid, Optofluidics",
author = "Thanin Schultheis and Dominik Hoheisel and Wenjia Xiao and Luca Spani-Molella and Eduard Reithmeier and Lutz Rissing and Steffen Hardt",
note = "Funding information: Acknowledgments This research work is funded by the German Research Foundation (DFG). Under grants are the projects FA 887/1-1, GA 481/35-1 and HA 2696/17-1, which are part of the Special Priority Program (SPP) 1337 {\textquoteleft}{\textquoteleft}Active Micro Optics{\textquoteright}{\textquoteright}.",
year = "2012",
month = mar,
day = "7",
doi = "10.1007/s10404-012-0961-3",
language = "English",
volume = "13",
pages = "299--308",
journal = "Microfluidics and Nanofluidics",
issn = "1613-4982",
publisher = "Springer Verlag",
number = "2",

}

Download

TY - JOUR

T1 - Performance of an adaptive liquid microlens controlled by a microcoil actuator

AU - Schultheis, Thanin

AU - Hoheisel, Dominik

AU - Xiao, Wenjia

AU - Spani-Molella, Luca

AU - Reithmeier, Eduard

AU - Rissing, Lutz

AU - Hardt, Steffen

N1 - Funding information: Acknowledgments This research work is funded by the German Research Foundation (DFG). Under grants are the projects FA 887/1-1, GA 481/35-1 and HA 2696/17-1, which are part of the Special Priority Program (SPP) 1337 ‘‘Active Micro Optics’’.

PY - 2012/3/7

Y1 - 2012/3/7

N2 - We present an optofluidic system based on electromagnetic manipulation of a ferrofluid to tune a liquid lens. Both studies of the dynamics of fluid transport and of the optical properties of the liquid lens have been carried out. Thermal and magnetic field simulations of the microcoil actuators are presented. Proof-of-principle experiments demonstrating the adaption of the focal length of the lens have been carried out. It is shown that the lens adaption proceeds in a reversible and reproducible manner, given that the ferrofluid plug moves with a speed below a specific threshold value. Furthermore, the time delay between the actuation and the deflection of the lens surface is studied.

AB - We present an optofluidic system based on electromagnetic manipulation of a ferrofluid to tune a liquid lens. Both studies of the dynamics of fluid transport and of the optical properties of the liquid lens have been carried out. Thermal and magnetic field simulations of the microcoil actuators are presented. Proof-of-principle experiments demonstrating the adaption of the focal length of the lens have been carried out. It is shown that the lens adaption proceeds in a reversible and reproducible manner, given that the ferrofluid plug moves with a speed below a specific threshold value. Furthermore, the time delay between the actuation and the deflection of the lens surface is studied.

KW - Keywords Ferrofluid

KW - Liquid lens

KW - Microactuator

KW - Microchannel

KW - Microcoil

KW - Microfluidics

KW - Microoptics

KW - Optical liquid

KW - Optofluidics

UR - http://www.scopus.com/inward/record.url?scp=84867231639&partnerID=8YFLogxK

U2 - 10.1007/s10404-012-0961-3

DO - 10.1007/s10404-012-0961-3

M3 - Article

AN - SCOPUS:84867231639

VL - 13

SP - 299

EP - 308

JO - Microfluidics and Nanofluidics

JF - Microfluidics and Nanofluidics

SN - 1613-4982

IS - 2

ER -