Performance analysis of three phase inverters controlled by synchronous delta-modulation systems

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

  • A. Mertens

Externe Organisationen

  • Rheinisch-Westfälische Technische Hochschule Aachen (RWTH)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksConference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992
Herausgeber (Verlag)Institute of Electrical and Electronics Engineers Inc.
Seiten779-788
Seitenumfang10
ISBN (elektronisch)078030635X
PublikationsstatusVeröffentlicht - 1992
Extern publiziertJa
VeranstaltungIEEE Industry Applications Society Annual Meeting, IAS 1992 - Houston, USA / Vereinigte Staaten
Dauer: 4 Okt. 19929 Okt. 1992

Publikationsreihe

NameConference Record - IAS Annual Meeting (IEEE Industry Applications Society)
Band1992-January
ISSN (Print)0197-2618

Abstract

Synchronous Delta-Modulation systems are used to control resonant voltage link inverters, where switching has to be synchronized with the zero crossings of the link voltage. This paper shows that output current harmonic distortion and average switching frequency of such systems can be calculated analytically in spite of the quasi stochastic behaviour of the modulator output. Under the assumption ofconstant link frequency and large ratio of link to output frequency, results are derivedfor three-phase Sigma-Delta-Modulation, space-vectorbased Sigma-Delta-Modulation and current regulated Delta-Modulation. The results hold for any shape of the inverter input voltage (including DC). The output current harmonic distortion of resonant link inverters is compared with conventional hard switching PWM inverters.

ASJC Scopus Sachgebiete

Zitieren

Performance analysis of three phase inverters controlled by synchronous delta-modulation systems. / Mertens, A.
Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992. Institute of Electrical and Electronics Engineers Inc., 1992. S. 779-788 244317 (Conference Record - IAS Annual Meeting (IEEE Industry Applications Society); Band 1992-January).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Mertens, A 1992, Performance analysis of three phase inverters controlled by synchronous delta-modulation systems. in Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992., 244317, Conference Record - IAS Annual Meeting (IEEE Industry Applications Society), Bd. 1992-January, Institute of Electrical and Electronics Engineers Inc., S. 779-788, IEEE Industry Applications Society Annual Meeting, IAS 1992, Houston, USA / Vereinigte Staaten, 4 Okt. 1992. https://doi.org/10.1109/IAS.1992.244317
Mertens, A. (1992). Performance analysis of three phase inverters controlled by synchronous delta-modulation systems. In Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992 (S. 779-788). Artikel 244317 (Conference Record - IAS Annual Meeting (IEEE Industry Applications Society); Band 1992-January). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/IAS.1992.244317
Mertens A. Performance analysis of three phase inverters controlled by synchronous delta-modulation systems. in Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992. Institute of Electrical and Electronics Engineers Inc. 1992. S. 779-788. 244317. (Conference Record - IAS Annual Meeting (IEEE Industry Applications Society)). doi: 10.1109/IAS.1992.244317
Mertens, A. / Performance analysis of three phase inverters controlled by synchronous delta-modulation systems. Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992. Institute of Electrical and Electronics Engineers Inc., 1992. S. 779-788 (Conference Record - IAS Annual Meeting (IEEE Industry Applications Society)).
Download
@inproceedings{fbeed04382dd48a28ee35d2493167cce,
title = "Performance analysis of three phase inverters controlled by synchronous delta-modulation systems",
abstract = "Synchronous Delta-Modulation systems are used to control resonant voltage link inverters, where switching has to be synchronized with the zero crossings of the link voltage. This paper shows that output current harmonic distortion and average switching frequency of such systems can be calculated analytically in spite of the quasi stochastic behaviour of the modulator output. Under the assumption ofconstant link frequency and large ratio of link to output frequency, results are derivedfor three-phase Sigma-Delta-Modulation, space-vectorbased Sigma-Delta-Modulation and current regulated Delta-Modulation. The results hold for any shape of the inverter input voltage (including DC). The output current harmonic distortion of resonant link inverters is compared with conventional hard switching PWM inverters.",
author = "A. Mertens",
year = "1992",
doi = "10.1109/IAS.1992.244317",
language = "English",
series = "Conference Record - IAS Annual Meeting (IEEE Industry Applications Society)",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
pages = "779--788",
booktitle = "Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992",
address = "United States",
note = "IEEE Industry Applications Society Annual Meeting, IAS 1992 ; Conference date: 04-10-1992 Through 09-10-1992",

}

Download

TY - GEN

T1 - Performance analysis of three phase inverters controlled by synchronous delta-modulation systems

AU - Mertens, A.

PY - 1992

Y1 - 1992

N2 - Synchronous Delta-Modulation systems are used to control resonant voltage link inverters, where switching has to be synchronized with the zero crossings of the link voltage. This paper shows that output current harmonic distortion and average switching frequency of such systems can be calculated analytically in spite of the quasi stochastic behaviour of the modulator output. Under the assumption ofconstant link frequency and large ratio of link to output frequency, results are derivedfor three-phase Sigma-Delta-Modulation, space-vectorbased Sigma-Delta-Modulation and current regulated Delta-Modulation. The results hold for any shape of the inverter input voltage (including DC). The output current harmonic distortion of resonant link inverters is compared with conventional hard switching PWM inverters.

AB - Synchronous Delta-Modulation systems are used to control resonant voltage link inverters, where switching has to be synchronized with the zero crossings of the link voltage. This paper shows that output current harmonic distortion and average switching frequency of such systems can be calculated analytically in spite of the quasi stochastic behaviour of the modulator output. Under the assumption ofconstant link frequency and large ratio of link to output frequency, results are derivedfor three-phase Sigma-Delta-Modulation, space-vectorbased Sigma-Delta-Modulation and current regulated Delta-Modulation. The results hold for any shape of the inverter input voltage (including DC). The output current harmonic distortion of resonant link inverters is compared with conventional hard switching PWM inverters.

UR - http://www.scopus.com/inward/record.url?scp=84958055983&partnerID=8YFLogxK

U2 - 10.1109/IAS.1992.244317

DO - 10.1109/IAS.1992.244317

M3 - Conference contribution

AN - SCOPUS:84958055983

T3 - Conference Record - IAS Annual Meeting (IEEE Industry Applications Society)

SP - 779

EP - 788

BT - Conference Record of the 1992 IEEE Industry Applications Society Annual Meeting, IAS 1992

PB - Institute of Electrical and Electronics Engineers Inc.

T2 - IEEE Industry Applications Society Annual Meeting, IAS 1992

Y2 - 4 October 1992 through 9 October 1992

ER -