Performance analysis of synchronous machines after disconnecting stator coils part II: Analytical steady-state solution method

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

  • Onur Misir
  • Jennifer Brand
  • Bernd Ponick
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des Sammelwerks2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017
Herausgeber (Verlag)Institute of Electrical and Electronics Engineers Inc.
ISBN (elektronisch)9781509042814
PublikationsstatusVeröffentlicht - 3 Aug. 2017
Veranstaltung2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017 - Miami, USA / Vereinigte Staaten
Dauer: 21 Mai 201724 Mai 2017

Abstract

This paper offers a new method to analyze the performance of three-phase synchronous machines operating with an unsymmetrical stator winding due to cut-out and bypassed coils. The resulting unsymmetrical current distribution in the stator winding tends to produce overheating of parts of the winding at full load and torque pulsations. Thus, the main objective of this study is to determine the maximal load, under which the unsymmetrical machine may operate without exceeding the permissible temperature limit. In this paper, based on the multi-loop method, the steady-state expression for each loop current is obtained by analyzing the steady-state characteristics of the stator and the rotor currents in case of missing stator coils. Thus, the system of differential equations in steady-state is reduced to a system of algebraic equations which can be solved by using the Gaussian elimination method. In order to evaluate the steady-state simulations, experiments with a bypassed stator coil were carried out on a 41 MW synchronous machine with two poles. Both the circulating current within parallel branches and the line currents as a result of coil cut-outs were analyzed.

ASJC Scopus Sachgebiete

Zitieren

Performance analysis of synchronous machines after disconnecting stator coils part II: Analytical steady-state solution method. / Misir, Onur; Brand, Jennifer; Ponick, Bernd.
2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017. Institute of Electrical and Electronics Engineers Inc., 2017. 8002032.

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Misir, O, Brand, J & Ponick, B 2017, Performance analysis of synchronous machines after disconnecting stator coils part II: Analytical steady-state solution method. in 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017., 8002032, Institute of Electrical and Electronics Engineers Inc., 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017, Miami, USA / Vereinigte Staaten, 21 Mai 2017. https://doi.org/10.1109/iemdc.2017.8002032
Misir, O., Brand, J., & Ponick, B. (2017). Performance analysis of synchronous machines after disconnecting stator coils part II: Analytical steady-state solution method. In 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017 Artikel 8002032 Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.1109/iemdc.2017.8002032
Misir O, Brand J, Ponick B. Performance analysis of synchronous machines after disconnecting stator coils part II: Analytical steady-state solution method. in 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017. Institute of Electrical and Electronics Engineers Inc. 2017. 8002032 doi: 10.1109/iemdc.2017.8002032
Misir, Onur ; Brand, Jennifer ; Ponick, Bernd. / Performance analysis of synchronous machines after disconnecting stator coils part II : Analytical steady-state solution method. 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017. Institute of Electrical and Electronics Engineers Inc., 2017.
Download
@inproceedings{33601eb17f7d4501b46d259f0beb4288,
title = "Performance analysis of synchronous machines after disconnecting stator coils part II: Analytical steady-state solution method",
abstract = "This paper offers a new method to analyze the performance of three-phase synchronous machines operating with an unsymmetrical stator winding due to cut-out and bypassed coils. The resulting unsymmetrical current distribution in the stator winding tends to produce overheating of parts of the winding at full load and torque pulsations. Thus, the main objective of this study is to determine the maximal load, under which the unsymmetrical machine may operate without exceeding the permissible temperature limit. In this paper, based on the multi-loop method, the steady-state expression for each loop current is obtained by analyzing the steady-state characteristics of the stator and the rotor currents in case of missing stator coils. Thus, the system of differential equations in steady-state is reduced to a system of algebraic equations which can be solved by using the Gaussian elimination method. In order to evaluate the steady-state simulations, experiments with a bypassed stator coil were carried out on a 41 MW synchronous machine with two poles. Both the circulating current within parallel branches and the line currents as a result of coil cut-outs were analyzed.",
keywords = "bypassed coils, circulating current, cut-out coils, multi-loop method, synchronous machine, unbalanced winding, winding fault",
author = "Onur Misir and Jennifer Brand and Bernd Ponick",
note = "Publisher Copyright: {\textcopyright} 2017 IEEE. Copyright: Copyright 2017 Elsevier B.V., All rights reserved.; 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017 ; Conference date: 21-05-2017 Through 24-05-2017",
year = "2017",
month = aug,
day = "3",
doi = "10.1109/iemdc.2017.8002032",
language = "English",
booktitle = "2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017",
publisher = "Institute of Electrical and Electronics Engineers Inc.",
address = "United States",

}

Download

TY - GEN

T1 - Performance analysis of synchronous machines after disconnecting stator coils part II

T2 - 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017

AU - Misir, Onur

AU - Brand, Jennifer

AU - Ponick, Bernd

N1 - Publisher Copyright: © 2017 IEEE. Copyright: Copyright 2017 Elsevier B.V., All rights reserved.

PY - 2017/8/3

Y1 - 2017/8/3

N2 - This paper offers a new method to analyze the performance of three-phase synchronous machines operating with an unsymmetrical stator winding due to cut-out and bypassed coils. The resulting unsymmetrical current distribution in the stator winding tends to produce overheating of parts of the winding at full load and torque pulsations. Thus, the main objective of this study is to determine the maximal load, under which the unsymmetrical machine may operate without exceeding the permissible temperature limit. In this paper, based on the multi-loop method, the steady-state expression for each loop current is obtained by analyzing the steady-state characteristics of the stator and the rotor currents in case of missing stator coils. Thus, the system of differential equations in steady-state is reduced to a system of algebraic equations which can be solved by using the Gaussian elimination method. In order to evaluate the steady-state simulations, experiments with a bypassed stator coil were carried out on a 41 MW synchronous machine with two poles. Both the circulating current within parallel branches and the line currents as a result of coil cut-outs were analyzed.

AB - This paper offers a new method to analyze the performance of three-phase synchronous machines operating with an unsymmetrical stator winding due to cut-out and bypassed coils. The resulting unsymmetrical current distribution in the stator winding tends to produce overheating of parts of the winding at full load and torque pulsations. Thus, the main objective of this study is to determine the maximal load, under which the unsymmetrical machine may operate without exceeding the permissible temperature limit. In this paper, based on the multi-loop method, the steady-state expression for each loop current is obtained by analyzing the steady-state characteristics of the stator and the rotor currents in case of missing stator coils. Thus, the system of differential equations in steady-state is reduced to a system of algebraic equations which can be solved by using the Gaussian elimination method. In order to evaluate the steady-state simulations, experiments with a bypassed stator coil were carried out on a 41 MW synchronous machine with two poles. Both the circulating current within parallel branches and the line currents as a result of coil cut-outs were analyzed.

KW - bypassed coils

KW - circulating current

KW - cut-out coils

KW - multi-loop method

KW - synchronous machine

KW - unbalanced winding

KW - winding fault

UR - http://www.scopus.com/inward/record.url?scp=85030320097&partnerID=8YFLogxK

U2 - 10.1109/iemdc.2017.8002032

DO - 10.1109/iemdc.2017.8002032

M3 - Conference contribution

AN - SCOPUS:85030320097

BT - 2017 IEEE International Electric Machines and Drives Conference, IEMDC 2017

PB - Institute of Electrical and Electronics Engineers Inc.

Y2 - 21 May 2017 through 24 May 2017

ER -