Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 323-330 |
Seitenumfang | 8 |
Fachzeitschrift | BIOLOGICALS |
Jahrgang | 37 |
Ausgabenummer | 5 |
Frühes Online-Datum | 31 Juli 2009 |
Publikationsstatus | Veröffentlicht - Okt. 2009 |
Abstract
Quality control for repeated bioassay runs can be performed by phase II control charts, well-known from industrial quality control. The value of interest is the potency, of which a single value per run is available. Parametric and non-parametric prediction intervals are described to estimate quality control intervals for future re-test runs. Violations against the normal distribution occur in real data frequently, particularly outliers. The non-parametric prediction intervals are limited to not too small sample sizes in both the historical and future sampling phases. Therefore, robust prediction intervals based on winsorization are proposed. R-functions for all prediction intervals are provided.
ASJC Scopus Sachgebiete
- Biochemie, Genetik und Molekularbiologie (insg.)
- Biotechnologie
- Chemische Verfahrenstechnik (insg.)
- Bioengineering
- Immunologie und Mikrobiologie (insg.)
- Angewandte Mikrobiologie und Biotechnologie
- Immunologie und Mikrobiologie (insg.)
- Allgemeine Immunologie und Mikrobiologie
- Pharmakologie, Toxikologie und Pharmazie (insg.)
- Pharmakologie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: BIOLOGICALS, Jahrgang 37, Nr. 5, 10.2009, S. 323-330.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Parametric and non-parametric prediction intervals based phase II control charts for repeated bioassay data
AU - Hothorn, L. A.
AU - Gerhard, D.
AU - Hofmann, M.
PY - 2009/10
Y1 - 2009/10
N2 - Quality control for repeated bioassay runs can be performed by phase II control charts, well-known from industrial quality control. The value of interest is the potency, of which a single value per run is available. Parametric and non-parametric prediction intervals are described to estimate quality control intervals for future re-test runs. Violations against the normal distribution occur in real data frequently, particularly outliers. The non-parametric prediction intervals are limited to not too small sample sizes in both the historical and future sampling phases. Therefore, robust prediction intervals based on winsorization are proposed. R-functions for all prediction intervals are provided.
AB - Quality control for repeated bioassay runs can be performed by phase II control charts, well-known from industrial quality control. The value of interest is the potency, of which a single value per run is available. Parametric and non-parametric prediction intervals are described to estimate quality control intervals for future re-test runs. Violations against the normal distribution occur in real data frequently, particularly outliers. The non-parametric prediction intervals are limited to not too small sample sizes in both the historical and future sampling phases. Therefore, robust prediction intervals based on winsorization are proposed. R-functions for all prediction intervals are provided.
KW - Bioassay
KW - Non-parametric control charts
KW - Phase II control charts
KW - Statistical quality control
UR - http://www.scopus.com/inward/record.url?scp=69649103730&partnerID=8YFLogxK
U2 - 10.1016/j.biologicals.2009.07.001
DO - 10.1016/j.biologicals.2009.07.001
M3 - Article
C2 - 19647449
AN - SCOPUS:69649103730
VL - 37
SP - 323
EP - 330
JO - BIOLOGICALS
JF - BIOLOGICALS
SN - 1045-1056
IS - 5
ER -