Oscillator strengths of Ti II from combined hook and emission measurements

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

  • K. Danzmann
  • M. Kock

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer012
Seiten (von - bis)2051-2059
Seitenumfang9
FachzeitschriftJournal of Physics B: Atomic and Molecular Physics
Jahrgang13
Ausgabenummer10
PublikationsstatusVeröffentlicht - Mai 1980

Abstract

It is demonstrated that a large set of accurate oscillator strengths of Ti II can be determined from a combination of hook and emission measurements without any assumption concerning the plasma state. Modified cascaded arcs and hollow cathode discharges have been used as plasma light sources for both hook and emission measurements. The relative f values have been converted to an absolute scale by means of literature data. The overall uncertainties of the f values are about 13-25%. Comparisons with other experimental and theoretical data are made which indicate excellent to fair agreement. Only for one of the published data sets has a wavelength-dependent discrepancy of up to a factor of two been found.

ASJC Scopus Sachgebiete

Zitieren

Oscillator strengths of Ti II from combined hook and emission measurements. / Danzmann, K.; Kock, M.
in: Journal of Physics B: Atomic and Molecular Physics, Jahrgang 13, Nr. 10, 012, 05.1980, S. 2051-2059.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Danzmann K, Kock M. Oscillator strengths of Ti II from combined hook and emission measurements. Journal of Physics B: Atomic and Molecular Physics. 1980 Mai;13(10):2051-2059. 012. doi: 10.1088/0022-3700/13/10/012
Download
@article{a3b74881520f4bb9b76592bea61ae161,
title = "Oscillator strengths of Ti II from combined hook and emission measurements",
abstract = "It is demonstrated that a large set of accurate oscillator strengths of Ti II can be determined from a combination of hook and emission measurements without any assumption concerning the plasma state. Modified cascaded arcs and hollow cathode discharges have been used as plasma light sources for both hook and emission measurements. The relative f values have been converted to an absolute scale by means of literature data. The overall uncertainties of the f values are about 13-25%. Comparisons with other experimental and theoretical data are made which indicate excellent to fair agreement. Only for one of the published data sets has a wavelength-dependent discrepancy of up to a factor of two been found.",
author = "K. Danzmann and M. Kock",
year = "1980",
month = may,
doi = "10.1088/0022-3700/13/10/012",
language = "English",
volume = "13",
pages = "2051--2059",
journal = "Journal of Physics B: Atomic and Molecular Physics",
issn = "0022-3700",
publisher = "IOP Publishing Ltd.",
number = "10",

}

Download

TY - JOUR

T1 - Oscillator strengths of Ti II from combined hook and emission measurements

AU - Danzmann, K.

AU - Kock, M.

PY - 1980/5

Y1 - 1980/5

N2 - It is demonstrated that a large set of accurate oscillator strengths of Ti II can be determined from a combination of hook and emission measurements without any assumption concerning the plasma state. Modified cascaded arcs and hollow cathode discharges have been used as plasma light sources for both hook and emission measurements. The relative f values have been converted to an absolute scale by means of literature data. The overall uncertainties of the f values are about 13-25%. Comparisons with other experimental and theoretical data are made which indicate excellent to fair agreement. Only for one of the published data sets has a wavelength-dependent discrepancy of up to a factor of two been found.

AB - It is demonstrated that a large set of accurate oscillator strengths of Ti II can be determined from a combination of hook and emission measurements without any assumption concerning the plasma state. Modified cascaded arcs and hollow cathode discharges have been used as plasma light sources for both hook and emission measurements. The relative f values have been converted to an absolute scale by means of literature data. The overall uncertainties of the f values are about 13-25%. Comparisons with other experimental and theoretical data are made which indicate excellent to fair agreement. Only for one of the published data sets has a wavelength-dependent discrepancy of up to a factor of two been found.

UR - http://www.scopus.com/inward/record.url?scp=0009714321&partnerID=8YFLogxK

U2 - 10.1088/0022-3700/13/10/012

DO - 10.1088/0022-3700/13/10/012

M3 - Article

AN - SCOPUS:0009714321

VL - 13

SP - 2051

EP - 2059

JO - Journal of Physics B: Atomic and Molecular Physics

JF - Journal of Physics B: Atomic and Molecular Physics

SN - 0022-3700

IS - 10

M1 - 012

ER -