Details
Titel in Übersetzung | Optimized arrival time determination of uhf pulses for localization of partial discharges in power transformers |
---|---|
Originalsprache | Deutsch |
Titel des Sammelwerks | VDE-Fachtagung Hochspannungstechnik 2018 |
Herausgeber (Verlag) | VDE Verlag GmbH |
Seiten | 291-296 |
Seitenumfang | 6 |
ISBN (elektronisch) | 9783800748075 |
Publikationsstatus | Veröffentlicht - 2018 |
Veranstaltung | VDE-Fachtagung Hochspannungstechnik 2018 - VDE Conference on High Voltage Technology 2018 - Berlin, Deutschland Dauer: 12 Nov. 2018 → 14 Nov. 2018 |
Publikationsreihe
Name | VDE-Fachtagung Hochspannungstechnik 2018 |
---|
Abstract
Location of a partial discharge (PD) fault inside a transformer can be determined using the Ultrahigh Frequency (UHF) PD measurement technique. Hereby, the electromagnetic waves that propagate due to the PD are captured using specially designed probes that are inserted into the transformer tank through its oil drain valves. The difference in the arrival time of these signals is the base of an equation system, where the PD location and the PD inception time are unknown. In this contribution, the influence of erroneous determined arrival times on the localization error is investigated using a two-dimensional analogy model. Furthermore, a novel method based on detection of abrupt changes in a certain statistical property of the signal for the arrival time determination is proposed. A test setup is utilized to evaluate the localization algorithm. Finally, the results are presented and the precision of the proposed method for PD localization using the UHF measurement technique is discussed.
ASJC Scopus Sachgebiete
- Energie (insg.)
- Energieanlagenbau und Kraftwerkstechnik
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
VDE-Fachtagung Hochspannungstechnik 2018. VDE Verlag GmbH, 2018. S. 291-296 (VDE-Fachtagung Hochspannungstechnik 2018).
Publikation: Beitrag in Buch/Bericht/Sammelwerk/Konferenzband › Aufsatz in Konferenzband › Forschung › Peer-Review
}
TY - GEN
T1 - Optimierte Bestimmung der Ankunftszeiten von UHF Signalen für die Lokalisierung von Teilentladungen in Leistungstransformatoren
AU - Akbari Azirani, Mohammad Esmaeil
AU - Ariannik, Mohamadreza
AU - Werle, Peter
AU - Akbari, Asghar Akbari
N1 - Publisher Copyright: © VDE VERLAG GMBH · Berlin · Offenbach Copyright: Copyright 2020 Elsevier B.V., All rights reserved.
PY - 2018
Y1 - 2018
N2 - Location of a partial discharge (PD) fault inside a transformer can be determined using the Ultrahigh Frequency (UHF) PD measurement technique. Hereby, the electromagnetic waves that propagate due to the PD are captured using specially designed probes that are inserted into the transformer tank through its oil drain valves. The difference in the arrival time of these signals is the base of an equation system, where the PD location and the PD inception time are unknown. In this contribution, the influence of erroneous determined arrival times on the localization error is investigated using a two-dimensional analogy model. Furthermore, a novel method based on detection of abrupt changes in a certain statistical property of the signal for the arrival time determination is proposed. A test setup is utilized to evaluate the localization algorithm. Finally, the results are presented and the precision of the proposed method for PD localization using the UHF measurement technique is discussed.
AB - Location of a partial discharge (PD) fault inside a transformer can be determined using the Ultrahigh Frequency (UHF) PD measurement technique. Hereby, the electromagnetic waves that propagate due to the PD are captured using specially designed probes that are inserted into the transformer tank through its oil drain valves. The difference in the arrival time of these signals is the base of an equation system, where the PD location and the PD inception time are unknown. In this contribution, the influence of erroneous determined arrival times on the localization error is investigated using a two-dimensional analogy model. Furthermore, a novel method based on detection of abrupt changes in a certain statistical property of the signal for the arrival time determination is proposed. A test setup is utilized to evaluate the localization algorithm. Finally, the results are presented and the precision of the proposed method for PD localization using the UHF measurement technique is discussed.
UR - http://www.scopus.com/inward/record.url?scp=85096805186&partnerID=8YFLogxK
M3 - Aufsatz in Konferenzband
AN - SCOPUS:85096805186
T3 - VDE-Fachtagung Hochspannungstechnik 2018
SP - 291
EP - 296
BT - VDE-Fachtagung Hochspannungstechnik 2018
PB - VDE Verlag GmbH
T2 - VDE-Fachtagung Hochspannungstechnik 2018 - VDE Conference on High Voltage Technology 2018
Y2 - 12 November 2018 through 14 November 2018
ER -