Abstract

Different optical sensing systems based on fluorometric detection for biotechnological purposes are presented. A fibre fluorometric sensor is described for monitoring the NADPH-dependent fluorescence of an enzyme complex from Z. mobilis for the analysis of glucose, fructose, gluconolactone or sorbitol. Optical chemosensors for pH and oxygen concentration were used as transducers for biooptodes for glucose, urea and pencillin. A two-channel device for the simultaneous monitoring of penicillin and pH is presented. Two fibre optic based immunosensors are described for the analysis of herbicides, mycotoxins and biotin. The use of the biotin sensor for the monitoring of a cultivation of recombinant E. coli is discussed.

ASJC Scopus Sachgebiete

Zitieren

Optical sensors for biotechnological applications. / Scheper, Th; Müller, C.; Anders, K. D. et al.
in: Biosensors and Bioelectronics, Jahrgang 9, Nr. 1, 1994, S. 73-82.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Scheper, T, Müller, C, Anders, KD, Eberhardt, F, Plötz, F, Schelp, C, Thordsen, O & Schügerl, K 1994, 'Optical sensors for biotechnological applications', Biosensors and Bioelectronics, Jg. 9, Nr. 1, S. 73-82. https://doi.org/10.1016/0956-5663(94)80017-0
Scheper, T., Müller, C., Anders, K. D., Eberhardt, F., Plötz, F., Schelp, C., Thordsen, O., & Schügerl, K. (1994). Optical sensors for biotechnological applications. Biosensors and Bioelectronics, 9(1), 73-82. https://doi.org/10.1016/0956-5663(94)80017-0
Scheper T, Müller C, Anders KD, Eberhardt F, Plötz F, Schelp C et al. Optical sensors for biotechnological applications. Biosensors and Bioelectronics. 1994;9(1):73-82. doi: 10.1016/0956-5663(94)80017-0
Scheper, Th ; Müller, C. ; Anders, K. D. et al. / Optical sensors for biotechnological applications. in: Biosensors and Bioelectronics. 1994 ; Jahrgang 9, Nr. 1. S. 73-82.
Download
@article{563ff1725ebb47fd92b38dae5a413704,
title = "Optical sensors for biotechnological applications",
abstract = "Different optical sensing systems based on fluorometric detection for biotechnological purposes are presented. A fibre fluorometric sensor is described for monitoring the NADPH-dependent fluorescence of an enzyme complex from Z. mobilis for the analysis of glucose, fructose, gluconolactone or sorbitol. Optical chemosensors for pH and oxygen concentration were used as transducers for biooptodes for glucose, urea and pencillin. A two-channel device for the simultaneous monitoring of penicillin and pH is presented. Two fibre optic based immunosensors are described for the analysis of herbicides, mycotoxins and biotin. The use of the biotin sensor for the monitoring of a cultivation of recombinant E. coli is discussed.",
keywords = "bioprocess monitoring, dehydrogenases, immunosensor, multicomponent sensing, optodes",
author = "Th Scheper and C. M{\"u}ller and Anders, {K. D.} and F. Eberhardt and F. Pl{\"o}tz and C. Schelp and O. Thordsen and K. Sch{\"u}gerl",
note = "Funding information: The authors would like to thank Professor H. Sahm and Dr. B. Rehr for their cooperation with the fluorometric biosensor; Prof. Dr. B. Hock (TU Munchen), Prof. Dr. G. Terplan and Dr. E. Mtirtlbauer( LMU Mtinchen)f or providing the appropriate antibodies; Dr. Weissgerber, Riedel de Haen Chemicals (Hannover), for his help with the atrazine assay, and the DFG, BMFT, Ingold MesstechnikA G, and the BWB Koblenz for financial assistance.",
year = "1994",
doi = "10.1016/0956-5663(94)80017-0",
language = "English",
volume = "9",
pages = "73--82",
journal = "Biosensors and Bioelectronics",
issn = "0956-5663",
publisher = "Elsevier Ltd.",
number = "1",

}

Download

TY - JOUR

T1 - Optical sensors for biotechnological applications

AU - Scheper, Th

AU - Müller, C.

AU - Anders, K. D.

AU - Eberhardt, F.

AU - Plötz, F.

AU - Schelp, C.

AU - Thordsen, O.

AU - Schügerl, K.

N1 - Funding information: The authors would like to thank Professor H. Sahm and Dr. B. Rehr for their cooperation with the fluorometric biosensor; Prof. Dr. B. Hock (TU Munchen), Prof. Dr. G. Terplan and Dr. E. Mtirtlbauer( LMU Mtinchen)f or providing the appropriate antibodies; Dr. Weissgerber, Riedel de Haen Chemicals (Hannover), for his help with the atrazine assay, and the DFG, BMFT, Ingold MesstechnikA G, and the BWB Koblenz for financial assistance.

PY - 1994

Y1 - 1994

N2 - Different optical sensing systems based on fluorometric detection for biotechnological purposes are presented. A fibre fluorometric sensor is described for monitoring the NADPH-dependent fluorescence of an enzyme complex from Z. mobilis for the analysis of glucose, fructose, gluconolactone or sorbitol. Optical chemosensors for pH and oxygen concentration were used as transducers for biooptodes for glucose, urea and pencillin. A two-channel device for the simultaneous monitoring of penicillin and pH is presented. Two fibre optic based immunosensors are described for the analysis of herbicides, mycotoxins and biotin. The use of the biotin sensor for the monitoring of a cultivation of recombinant E. coli is discussed.

AB - Different optical sensing systems based on fluorometric detection for biotechnological purposes are presented. A fibre fluorometric sensor is described for monitoring the NADPH-dependent fluorescence of an enzyme complex from Z. mobilis for the analysis of glucose, fructose, gluconolactone or sorbitol. Optical chemosensors for pH and oxygen concentration were used as transducers for biooptodes for glucose, urea and pencillin. A two-channel device for the simultaneous monitoring of penicillin and pH is presented. Two fibre optic based immunosensors are described for the analysis of herbicides, mycotoxins and biotin. The use of the biotin sensor for the monitoring of a cultivation of recombinant E. coli is discussed.

KW - bioprocess monitoring

KW - dehydrogenases

KW - immunosensor

KW - multicomponent sensing

KW - optodes

UR - http://www.scopus.com/inward/record.url?scp=0028174391&partnerID=8YFLogxK

U2 - 10.1016/0956-5663(94)80017-0

DO - 10.1016/0956-5663(94)80017-0

M3 - Article

AN - SCOPUS:0028174391

VL - 9

SP - 73

EP - 82

JO - Biosensors and Bioelectronics

JF - Biosensors and Bioelectronics

SN - 0956-5663

IS - 1

ER -

Von denselben Autoren