Optical chemo- and biosensors for use in clinical applications

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autorschaft

Organisationseinheiten

Externe Organisationen

  • Physikalisch-Technische Bundesanstalt (PTB)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)71-77
Seitenumfang7
FachzeitschriftSensors and Actuators, B: Chemical
Jahrgang40
Ausgabenummer1
PublikationsstatusVeröffentlicht - 1 Mai 1997

Abstract

The development of pH-based fibre-optic biosensors for penicillin, urea, creatinin and glucose and their uses in clinical applications are described. A simple but very efficient way of constructing biosensors is to immobilize an enzyme layer directly on the tip of a pH optode. Biosensors based on pH probes depend on critical factors such as the pH value and buffer ion concentration in the sample media. Since biosensors cannot be sterilized due to the instability of the biological component, they are normally integrated into flow-injection-analysis (FIA) systems. The complex signal is transformed and analysed by a computer system. Characteristic features of the FIA peak give information about the buffer capacity in the solution. With the help of intelligent computing (neural networks), it is possible to recognize these features and relate them to the respective buffer capacity to obtain more accurate values.

ASJC Scopus Sachgebiete

Zitieren

Optical chemo- and biosensors for use in clinical applications. / Müller, Cord; Hitzmann, Bernd; Schubert, Florian et al.
in: Sensors and Actuators, B: Chemical, Jahrgang 40, Nr. 1, 01.05.1997, S. 71-77.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Müller C, Hitzmann B, Schubert F, Scheper T. Optical chemo- and biosensors for use in clinical applications. Sensors and Actuators, B: Chemical. 1997 Mai 1;40(1):71-77. doi: 10.1016/S0925-4005(97)00016-6
Müller, Cord ; Hitzmann, Bernd ; Schubert, Florian et al. / Optical chemo- and biosensors for use in clinical applications. in: Sensors and Actuators, B: Chemical. 1997 ; Jahrgang 40, Nr. 1. S. 71-77.
Download
@article{b43756862f514318842dbee536945d29,
title = "Optical chemo- and biosensors for use in clinical applications",
abstract = "The development of pH-based fibre-optic biosensors for penicillin, urea, creatinin and glucose and their uses in clinical applications are described. A simple but very efficient way of constructing biosensors is to immobilize an enzyme layer directly on the tip of a pH optode. Biosensors based on pH probes depend on critical factors such as the pH value and buffer ion concentration in the sample media. Since biosensors cannot be sterilized due to the instability of the biological component, they are normally integrated into flow-injection-analysis (FIA) systems. The complex signal is transformed and analysed by a computer system. Characteristic features of the FIA peak give information about the buffer capacity in the solution. With the help of intelligent computing (neural networks), it is possible to recognize these features and relate them to the respective buffer capacity to obtain more accurate values.",
keywords = "Biosensors, Flow-injection analysis, Neural networks, Optodes",
author = "Cord M{\"u}ller and Bernd Hitzmann and Florian Schubert and Thomas Scheper",
year = "1997",
month = may,
day = "1",
doi = "10.1016/S0925-4005(97)00016-6",
language = "English",
volume = "40",
pages = "71--77",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "1",

}

Download

TY - JOUR

T1 - Optical chemo- and biosensors for use in clinical applications

AU - Müller, Cord

AU - Hitzmann, Bernd

AU - Schubert, Florian

AU - Scheper, Thomas

PY - 1997/5/1

Y1 - 1997/5/1

N2 - The development of pH-based fibre-optic biosensors for penicillin, urea, creatinin and glucose and their uses in clinical applications are described. A simple but very efficient way of constructing biosensors is to immobilize an enzyme layer directly on the tip of a pH optode. Biosensors based on pH probes depend on critical factors such as the pH value and buffer ion concentration in the sample media. Since biosensors cannot be sterilized due to the instability of the biological component, they are normally integrated into flow-injection-analysis (FIA) systems. The complex signal is transformed and analysed by a computer system. Characteristic features of the FIA peak give information about the buffer capacity in the solution. With the help of intelligent computing (neural networks), it is possible to recognize these features and relate them to the respective buffer capacity to obtain more accurate values.

AB - The development of pH-based fibre-optic biosensors for penicillin, urea, creatinin and glucose and their uses in clinical applications are described. A simple but very efficient way of constructing biosensors is to immobilize an enzyme layer directly on the tip of a pH optode. Biosensors based on pH probes depend on critical factors such as the pH value and buffer ion concentration in the sample media. Since biosensors cannot be sterilized due to the instability of the biological component, they are normally integrated into flow-injection-analysis (FIA) systems. The complex signal is transformed and analysed by a computer system. Characteristic features of the FIA peak give information about the buffer capacity in the solution. With the help of intelligent computing (neural networks), it is possible to recognize these features and relate them to the respective buffer capacity to obtain more accurate values.

KW - Biosensors

KW - Flow-injection analysis

KW - Neural networks

KW - Optodes

UR - http://www.scopus.com/inward/record.url?scp=0031131390&partnerID=8YFLogxK

U2 - 10.1016/S0925-4005(97)00016-6

DO - 10.1016/S0925-4005(97)00016-6

M3 - Article

AN - SCOPUS:0031131390

VL - 40

SP - 71

EP - 77

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 1

ER -