Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 471-476 |
Seitenumfang | 6 |
Fachzeitschrift | Applied Microbiology and Biotechnology |
Jahrgang | 35 |
Ausgabenummer | 4 |
Publikationsstatus | Veröffentlicht - Juli 1991 |
Abstract
An automated turbidimetric immunoassay for pullulanase from Clostridium thermosulfurogenes was developed for on-line bioprocess monitoring. Measurements are based on the turbidity caused by specific aggregation between pullulanase molecules present in the cultivation medium and antibodies against these enzymes. The time for one assay cycle is 3.0 min. Pullulanase concentrations between 10 units (U)/l and 1000 U/l could be measured. Standard deviations of less than 2% were found. The analysis system could be successfully employed for on-line product monitoring during a 240-h cultivation of C. thermosulfurogenes. An average correlation factor of 0.975 was obtained for the pullulanase data from on-line turbidimetric and the off-line reference assay, demonstrating the accuracy of this on-line method.
ASJC Scopus Sachgebiete
- Biochemie, Genetik und Molekularbiologie (insg.)
- Biotechnologie
- Immunologie und Mikrobiologie (insg.)
- Angewandte Mikrobiologie und Biotechnologie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Applied Microbiology and Biotechnology, Jahrgang 35, Nr. 4, 07.1991, S. 471-476.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - On-line monitoring of pullulanase production during continuous culture of Clostridium thermosulfurogenes
AU - Freitag, Ruth
AU - Scheper, Thomas
AU - Spreinat, Andreas
AU - Antranikian, Garo
PY - 1991/7
Y1 - 1991/7
N2 - An automated turbidimetric immunoassay for pullulanase from Clostridium thermosulfurogenes was developed for on-line bioprocess monitoring. Measurements are based on the turbidity caused by specific aggregation between pullulanase molecules present in the cultivation medium and antibodies against these enzymes. The time for one assay cycle is 3.0 min. Pullulanase concentrations between 10 units (U)/l and 1000 U/l could be measured. Standard deviations of less than 2% were found. The analysis system could be successfully employed for on-line product monitoring during a 240-h cultivation of C. thermosulfurogenes. An average correlation factor of 0.975 was obtained for the pullulanase data from on-line turbidimetric and the off-line reference assay, demonstrating the accuracy of this on-line method.
AB - An automated turbidimetric immunoassay for pullulanase from Clostridium thermosulfurogenes was developed for on-line bioprocess monitoring. Measurements are based on the turbidity caused by specific aggregation between pullulanase molecules present in the cultivation medium and antibodies against these enzymes. The time for one assay cycle is 3.0 min. Pullulanase concentrations between 10 units (U)/l and 1000 U/l could be measured. Standard deviations of less than 2% were found. The analysis system could be successfully employed for on-line product monitoring during a 240-h cultivation of C. thermosulfurogenes. An average correlation factor of 0.975 was obtained for the pullulanase data from on-line turbidimetric and the off-line reference assay, demonstrating the accuracy of this on-line method.
UR - http://www.scopus.com/inward/record.url?scp=0025830334&partnerID=8YFLogxK
U2 - 10.1007/BF00169752
DO - 10.1007/BF00169752
M3 - Article
AN - SCOPUS:0025830334
VL - 35
SP - 471
EP - 476
JO - Applied Microbiology and Biotechnology
JF - Applied Microbiology and Biotechnology
SN - 0175-7598
IS - 4