Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 139-143 |
Seitenumfang | 5 |
Fachzeitschrift | Journal of biotechnology |
Jahrgang | 46 |
Ausgabenummer | 2 |
Publikationsstatus | Veröffentlicht - 30 Apr. 1996 |
Abstract
Lipase-catalyzed kinetic resolution of 3-hydroxyoctanoic acid methylester in supercritical carbon dioxide has been investigated. The reaction progress was monitored on-line following the absorbance of the by-product acetic aldehyde using a UV photometer equipped with a high pressure flow through cell. The conversion determined by this method was in very good accordance with results obtained by off-line sampling and subsequent analysis by gas chromatography using a chiral column.
ASJC Scopus Sachgebiete
- Biochemie, Genetik und Molekularbiologie (insg.)
- Biotechnologie
- Chemische Verfahrenstechnik (insg.)
- Bioengineering
- Immunologie und Mikrobiologie (insg.)
- Angewandte Mikrobiologie und Biotechnologie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Journal of biotechnology, Jahrgang 46, Nr. 2, 30.04.1996, S. 139-143.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - On-line determination of the conversion in a lipase-catalyzed kinetic resolution in supercritical carbon dioxide
AU - Bornscheuer, U.
AU - Capewell, A.
AU - Wendel, V.
AU - Scheper, T.
PY - 1996/4/30
Y1 - 1996/4/30
N2 - Lipase-catalyzed kinetic resolution of 3-hydroxyoctanoic acid methylester in supercritical carbon dioxide has been investigated. The reaction progress was monitored on-line following the absorbance of the by-product acetic aldehyde using a UV photometer equipped with a high pressure flow through cell. The conversion determined by this method was in very good accordance with results obtained by off-line sampling and subsequent analysis by gas chromatography using a chiral column.
AB - Lipase-catalyzed kinetic resolution of 3-hydroxyoctanoic acid methylester in supercritical carbon dioxide has been investigated. The reaction progress was monitored on-line following the absorbance of the by-product acetic aldehyde using a UV photometer equipped with a high pressure flow through cell. The conversion determined by this method was in very good accordance with results obtained by off-line sampling and subsequent analysis by gas chromatography using a chiral column.
KW - 3-Hydroxy ester
KW - Kinetic resolution
KW - Lipase
KW - On-line analysis
KW - Supercritical carbon dioxide
UR - http://www.scopus.com/inward/record.url?scp=0030131030&partnerID=8YFLogxK
U2 - 10.1016/0168-1656(95)00195-6
DO - 10.1016/0168-1656(95)00195-6
M3 - Article
AN - SCOPUS:0030131030
VL - 46
SP - 139
EP - 143
JO - Journal of biotechnology
JF - Journal of biotechnology
SN - 0168-1656
IS - 2
ER -