Abstract
This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R2 = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R2 = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.
ASJC Scopus Sachgebiete
- Biochemie, Genetik und Molekularbiologie (insg.)
- Biotechnologie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Biotechnology progress, Jahrgang 27, Nr. 2, 12.11.2010, S. 530-538.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes
AU - Yuksel, Merve
AU - Akin, Mehriban
AU - Geyik, Caner
AU - Demirkol, Dilek Odaci
AU - Ozdemir, Caglar
AU - Bluma, Arne
AU - Höpfner, Tim
AU - Beutel, Sascha
AU - Timur, Suna
AU - Scheper, Thomas
PY - 2010/11/12
Y1 - 2010/11/12
N2 - This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R2 = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R2 = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.
AB - This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R2 = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R2 = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.
KW - Flow injection analysis
KW - Glucose biomonitoring
KW - Glucose oxidase
KW - Pyranose oxidase
KW - Self-assembled monolayers
UR - http://www.scopus.com/inward/record.url?scp=79952538013&partnerID=8YFLogxK
U2 - 10.1002/btpr.544
DO - 10.1002/btpr.544
M3 - Article
C2 - 21485034
AN - SCOPUS:79952538013
VL - 27
SP - 530
EP - 538
JO - Biotechnology progress
JF - Biotechnology progress
SN - 8756-7938
IS - 2
ER -