Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Organisationseinheiten

Externe Organisationen

  • Ege University
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)530-538
Seitenumfang9
FachzeitschriftBiotechnology progress
Jahrgang27
Ausgabenummer2
PublikationsstatusVeröffentlicht - 12 Nov. 2010

Abstract

This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R2 = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R2 = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.

ASJC Scopus Sachgebiete

Zitieren

Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes. / Yuksel, Merve; Akin, Mehriban; Geyik, Caner et al.
in: Biotechnology progress, Jahrgang 27, Nr. 2, 12.11.2010, S. 530-538.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Yuksel, M, Akin, M, Geyik, C, Demirkol, DO, Ozdemir, C, Bluma, A, Höpfner, T, Beutel, S, Timur, S & Scheper, T 2010, 'Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes', Biotechnology progress, Jg. 27, Nr. 2, S. 530-538. https://doi.org/10.1002/btpr.544
Yuksel, M., Akin, M., Geyik, C., Demirkol, D. O., Ozdemir, C., Bluma, A., Höpfner, T., Beutel, S., Timur, S., & Scheper, T. (2010). Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes. Biotechnology progress, 27(2), 530-538. https://doi.org/10.1002/btpr.544
Yuksel M, Akin M, Geyik C, Demirkol DO, Ozdemir C, Bluma A et al. Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes. Biotechnology progress. 2010 Nov 12;27(2):530-538. doi: 10.1002/btpr.544
Yuksel, Merve ; Akin, Mehriban ; Geyik, Caner et al. / Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes. in: Biotechnology progress. 2010 ; Jahrgang 27, Nr. 2. S. 530-538.
Download
@article{a8118377a3fa47c1874c5f9e3b109aa1,
title = "Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes",
abstract = "This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R2 = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R2 = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.",
keywords = "Flow injection analysis, Glucose biomonitoring, Glucose oxidase, Pyranose oxidase, Self-assembled monolayers",
author = "Merve Yuksel and Mehriban Akin and Caner Geyik and Demirkol, {Dilek Odaci} and Caglar Ozdemir and Arne Bluma and Tim H{\"o}pfner and Sascha Beutel and Suna Timur and Thomas Scheper",
year = "2010",
month = nov,
day = "12",
doi = "10.1002/btpr.544",
language = "English",
volume = "27",
pages = "530--538",
journal = "Biotechnology progress",
issn = "8756-7938",
publisher = "Wiley-Blackwell",
number = "2",

}

Download

TY - JOUR

T1 - Offline Glucose Biomonitoring in Yeast Culture by Polyamidoamine/Cysteamine-Modified Gold Electrodes

AU - Yuksel, Merve

AU - Akin, Mehriban

AU - Geyik, Caner

AU - Demirkol, Dilek Odaci

AU - Ozdemir, Caglar

AU - Bluma, Arne

AU - Höpfner, Tim

AU - Beutel, Sascha

AU - Timur, Suna

AU - Scheper, Thomas

PY - 2010/11/12

Y1 - 2010/11/12

N2 - This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R2 = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R2 = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.

AB - This article deals with the use of pyranose oxidase (PyOx) and glucose oxidase (GOx) enzymes in amperometric biosensor design and their application in monitoring fermentation processes with the combination of flow injection analysis (FIA). The amperometric studies were carried out at -0.7 V by following the oxygen consumption due to the enzymatic reactions for both batch and FIA modes. Optimization studies (enzyme amounts and pH) and analytical parameters such as linearity, repeatability, effect of interference, storage, and operational stabilities have been studied. Under optimized conditions, for the PyOx-based biosensor, linear graph was obtained from 0.025 to 0.5 mM glucose in phosphate buffer (50 mM) at pH 7.0 with the equation of y = 3.358x + 0.028 and R2 = 0.998. Linearity was found to be 0.01-1.0 mM in citrate buffer (50 mM and pH 4.0) with the equation of y = 1.539x + 0.181 and R2 = 0.992 for the GOx biosensor. Finally, these biosensor configurations were further evaluated in a conventional flow injection system. Results from batch experiments provide a guide to design sensitive, stable, and interference-free biosensors for FIA mode. Biosensor stability, dynamic range, and repeatability were also studied in FIA conditions, and the applicability for the determination of glucose in fermentation medium could be successfully demonstrated. The FIA-combined glucose biosensor was used for the offline monitoring of yeast fermentation. The obtained results correlated well with HPLC measurements.

KW - Flow injection analysis

KW - Glucose biomonitoring

KW - Glucose oxidase

KW - Pyranose oxidase

KW - Self-assembled monolayers

UR - http://www.scopus.com/inward/record.url?scp=79952538013&partnerID=8YFLogxK

U2 - 10.1002/btpr.544

DO - 10.1002/btpr.544

M3 - Article

C2 - 21485034

AN - SCOPUS:79952538013

VL - 27

SP - 530

EP - 538

JO - Biotechnology progress

JF - Biotechnology progress

SN - 8756-7938

IS - 2

ER -

Von denselben Autoren