Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autorschaft

  • A. Bouguecha
  • I. Elgaly
  • C. Stukenborg-Colsman
  • M. Lerch
  • I. Nolte
  • P. Wefstaedt
  • T. Matthias
  • B. A. Behrens

Externe Organisationen

  • Medizinische Hochschule Hannover (MHH)
  • Stiftung Tierärztliche Hochschule Hannover
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksXII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010
Seiten562-565
Seitenumfang4
PublikationsstatusVeröffentlicht - Okt. 2010
Veranstaltung12th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2010 - Chalkidiki, Griechenland
Dauer: 27 Mai 201030 Mai 2010

Publikationsreihe

NameIFMBE Proceedings
Band29
ISSN (Print)1680-0737

Abstract

Bone remodeling due to stress shielding is a major cause of hip implants aseptic loosening. Previously, investigations on this phenomenon were based mainly on clinical observations. Currently, the finite element method (FEM) has been established as a reliable and efficient computing method to examine stress shielding after total hip arthroplasty and the related bone remodeling in the prosthetic Femur. The life of hip implants is not only limited by the loosening of the prosthesis stem, but also frequently affected by the loosening of acetabular components caused - among other factors - by resorption of the bone surrounding the prosthesis due to stress shielding. However, only few numerical research studies, which focus on the FE computation of the strainadaptive bone remodeling in the prosthetic pelvis, have been published. The aim of the work presented here is to estimate the changes in the physiological load distribution and the resulting bone remodeling in a pelvis provided with a cemented acetabular prosthesis component (cup) based on FEM. Therefore, a three-dimensional FE model of the left intact pelvis half was initially reconstructed based on CT data of a male patient with 85 kg weight. In a further step, a FE model of the prosthetic pelvis was built. The anchoring of the considered acetabular prosthesis component was carried out using a homogeneous cement layer of 2 mm thickness. Then the change of the apparent bone density in the prosthetic pelvis was calculated by means of FEM and the strain-adaptive bone remodeling in the acetabular region was analyzed. The analysis of the numerical results reflects significant estimated bone loss, especially in the acetabular limbus adjacent to the cup. As a result, loosening of the cemented prosthesis component can be anticipated.

ASJC Scopus Sachgebiete

Zitieren

Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis. / Bouguecha, A.; Elgaly, I.; Stukenborg-Colsman, C. et al.
XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010. 2010. S. 562-565 (IFMBE Proceedings; Band 29).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Bouguecha, A, Elgaly, I, Stukenborg-Colsman, C, Lerch, M, Nolte, I, Wefstaedt, P, Matthias, T & Behrens, BA 2010, Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis. in XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010. IFMBE Proceedings, Bd. 29, S. 562-565, 12th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2010, Chalkidiki, Griechenland, 27 Mai 2010. https://doi.org/10.1007/978-3-642-13039-7_141
Bouguecha, A., Elgaly, I., Stukenborg-Colsman, C., Lerch, M., Nolte, I., Wefstaedt, P., Matthias, T., & Behrens, B. A. (2010). Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis. In XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010 (S. 562-565). (IFMBE Proceedings; Band 29). https://doi.org/10.1007/978-3-642-13039-7_141
Bouguecha A, Elgaly I, Stukenborg-Colsman C, Lerch M, Nolte I, Wefstaedt P et al. Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis. in XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010. 2010. S. 562-565. (IFMBE Proceedings). doi: 10.1007/978-3-642-13039-7_141
Bouguecha, A. ; Elgaly, I. ; Stukenborg-Colsman, C. et al. / Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis. XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010. 2010. S. 562-565 (IFMBE Proceedings).
Download
@inproceedings{6fd3e806051a48209368f00ffd9ce3f5,
title = "Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis",
abstract = "Bone remodeling due to stress shielding is a major cause of hip implants aseptic loosening. Previously, investigations on this phenomenon were based mainly on clinical observations. Currently, the finite element method (FEM) has been established as a reliable and efficient computing method to examine stress shielding after total hip arthroplasty and the related bone remodeling in the prosthetic Femur. The life of hip implants is not only limited by the loosening of the prosthesis stem, but also frequently affected by the loosening of acetabular components caused - among other factors - by resorption of the bone surrounding the prosthesis due to stress shielding. However, only few numerical research studies, which focus on the FE computation of the strainadaptive bone remodeling in the prosthetic pelvis, have been published. The aim of the work presented here is to estimate the changes in the physiological load distribution and the resulting bone remodeling in a pelvis provided with a cemented acetabular prosthesis component (cup) based on FEM. Therefore, a three-dimensional FE model of the left intact pelvis half was initially reconstructed based on CT data of a male patient with 85 kg weight. In a further step, a FE model of the prosthetic pelvis was built. The anchoring of the considered acetabular prosthesis component was carried out using a homogeneous cement layer of 2 mm thickness. Then the change of the apparent bone density in the prosthetic pelvis was calculated by means of FEM and the strain-adaptive bone remodeling in the acetabular region was analyzed. The analysis of the numerical results reflects significant estimated bone loss, especially in the acetabular limbus adjacent to the cup. As a result, loosening of the cemented prosthesis component can be anticipated.",
keywords = "bone remodeling, cemented cup, FEM, pelvis",
author = "A. Bouguecha and I. Elgaly and C. Stukenborg-Colsman and M. Lerch and I. Nolte and P. Wefstaedt and T. Matthias and Behrens, {B. A.}",
year = "2010",
month = oct,
doi = "10.1007/978-3-642-13039-7_141",
language = "English",
isbn = "9783642130380",
series = "IFMBE Proceedings",
pages = "562--565",
booktitle = "XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010",
note = "12th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2010 ; Conference date: 27-05-2010 Through 30-05-2010",

}

Download

TY - GEN

T1 - Numerical Investigations of the Strain-Adaptive Bone Remodeling in the Prosthetic Pelvis

AU - Bouguecha, A.

AU - Elgaly, I.

AU - Stukenborg-Colsman, C.

AU - Lerch, M.

AU - Nolte, I.

AU - Wefstaedt, P.

AU - Matthias, T.

AU - Behrens, B. A.

PY - 2010/10

Y1 - 2010/10

N2 - Bone remodeling due to stress shielding is a major cause of hip implants aseptic loosening. Previously, investigations on this phenomenon were based mainly on clinical observations. Currently, the finite element method (FEM) has been established as a reliable and efficient computing method to examine stress shielding after total hip arthroplasty and the related bone remodeling in the prosthetic Femur. The life of hip implants is not only limited by the loosening of the prosthesis stem, but also frequently affected by the loosening of acetabular components caused - among other factors - by resorption of the bone surrounding the prosthesis due to stress shielding. However, only few numerical research studies, which focus on the FE computation of the strainadaptive bone remodeling in the prosthetic pelvis, have been published. The aim of the work presented here is to estimate the changes in the physiological load distribution and the resulting bone remodeling in a pelvis provided with a cemented acetabular prosthesis component (cup) based on FEM. Therefore, a three-dimensional FE model of the left intact pelvis half was initially reconstructed based on CT data of a male patient with 85 kg weight. In a further step, a FE model of the prosthetic pelvis was built. The anchoring of the considered acetabular prosthesis component was carried out using a homogeneous cement layer of 2 mm thickness. Then the change of the apparent bone density in the prosthetic pelvis was calculated by means of FEM and the strain-adaptive bone remodeling in the acetabular region was analyzed. The analysis of the numerical results reflects significant estimated bone loss, especially in the acetabular limbus adjacent to the cup. As a result, loosening of the cemented prosthesis component can be anticipated.

AB - Bone remodeling due to stress shielding is a major cause of hip implants aseptic loosening. Previously, investigations on this phenomenon were based mainly on clinical observations. Currently, the finite element method (FEM) has been established as a reliable and efficient computing method to examine stress shielding after total hip arthroplasty and the related bone remodeling in the prosthetic Femur. The life of hip implants is not only limited by the loosening of the prosthesis stem, but also frequently affected by the loosening of acetabular components caused - among other factors - by resorption of the bone surrounding the prosthesis due to stress shielding. However, only few numerical research studies, which focus on the FE computation of the strainadaptive bone remodeling in the prosthetic pelvis, have been published. The aim of the work presented here is to estimate the changes in the physiological load distribution and the resulting bone remodeling in a pelvis provided with a cemented acetabular prosthesis component (cup) based on FEM. Therefore, a three-dimensional FE model of the left intact pelvis half was initially reconstructed based on CT data of a male patient with 85 kg weight. In a further step, a FE model of the prosthetic pelvis was built. The anchoring of the considered acetabular prosthesis component was carried out using a homogeneous cement layer of 2 mm thickness. Then the change of the apparent bone density in the prosthetic pelvis was calculated by means of FEM and the strain-adaptive bone remodeling in the acetabular region was analyzed. The analysis of the numerical results reflects significant estimated bone loss, especially in the acetabular limbus adjacent to the cup. As a result, loosening of the cemented prosthesis component can be anticipated.

KW - bone remodeling

KW - cemented cup

KW - FEM

KW - pelvis

UR - http://www.scopus.com/inward/record.url?scp=77957603428&partnerID=8YFLogxK

U2 - 10.1007/978-3-642-13039-7_141

DO - 10.1007/978-3-642-13039-7_141

M3 - Conference contribution

AN - SCOPUS:77957603428

SN - 9783642130380

T3 - IFMBE Proceedings

SP - 562

EP - 565

BT - XII Mediterranean Conference on Medical and Biological Engineering and Computing 2010, MEDICON 2010

T2 - 12th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2010

Y2 - 27 May 2010 through 30 May 2010

ER -