Nonlinear frequency response analysis for the diagnosis of carbon monoxide poisoning in PEM fuel cell anodes

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Externe Organisationen

  • Max-Planck-Institut für Dynamik komplexer technischer Systeme
  • Otto-von-Guericke-Universität Magdeburg
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)1021-1032
Seitenumfang12
FachzeitschriftJournal of Applied Electrochemistry
Jahrgang41
Ausgabenummer9
PublikationsstatusVeröffentlicht - Sept. 2011
Extern publiziertJa

Abstract

Anodic CO poisoning of a PEMFC was analysed by nonlinear frequency response analysis (NFRA) in a differential H2/H2 cell. This special experimental setup excluded potential masking effects, emphasised the main mechanism of CO poisoning and made a simplified modelling approach possible. The main features of CO poisoning were investigated by means of steady state polarisation, EIS and NFRA. The main characteristics of CO poisoning in the NFRA spectra can be used as a "fingerprint" for diagnostic purposes.

Schlagwörter

    Carbon monoxide, Higher order frequency response function, Nonlinear frequency response analysis, Polymer electrolyte membrane fuel cell

ASJC Scopus Sachgebiete

Zitieren

Nonlinear frequency response analysis for the diagnosis of carbon monoxide poisoning in PEM fuel cell anodes. / Kadyk, Thomas; Hanke-Rauschenbach, Richard; Sundmacher, Kai.
in: Journal of Applied Electrochemistry, Jahrgang 41, Nr. 9, 09.2011, S. 1021-1032.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{381a988d129f489ea1e4eebf77fb9a7c,
title = "Nonlinear frequency response analysis for the diagnosis of carbon monoxide poisoning in PEM fuel cell anodes",
abstract = "Anodic CO poisoning of a PEMFC was analysed by nonlinear frequency response analysis (NFRA) in a differential H2/H2 cell. This special experimental setup excluded potential masking effects, emphasised the main mechanism of CO poisoning and made a simplified modelling approach possible. The main features of CO poisoning were investigated by means of steady state polarisation, EIS and NFRA. The main characteristics of CO poisoning in the NFRA spectra can be used as a {"}fingerprint{"} for diagnostic purposes.",
keywords = "Carbon monoxide, Higher order frequency response function, Nonlinear frequency response analysis, Polymer electrolyte membrane fuel cell, Carbon monoxide, Higher order frequency response function, Nonlinear frequency response analysis, Polymer electrolyte membrane fuel cell",
author = "Thomas Kadyk and Richard Hanke-Rauschenbach and Kai Sundmacher",
note = "Copyright: Copyright 2011 Elsevier B.V., All rights reserved.",
year = "2011",
month = sep,
doi = "10.1007/s10800-011-0298-8",
language = "English",
volume = "41",
pages = "1021--1032",
journal = "Journal of Applied Electrochemistry",
issn = "0021-891X",
publisher = "Springer Netherlands",
number = "9",

}

Download

TY - JOUR

T1 - Nonlinear frequency response analysis for the diagnosis of carbon monoxide poisoning in PEM fuel cell anodes

AU - Kadyk, Thomas

AU - Hanke-Rauschenbach, Richard

AU - Sundmacher, Kai

N1 - Copyright: Copyright 2011 Elsevier B.V., All rights reserved.

PY - 2011/9

Y1 - 2011/9

N2 - Anodic CO poisoning of a PEMFC was analysed by nonlinear frequency response analysis (NFRA) in a differential H2/H2 cell. This special experimental setup excluded potential masking effects, emphasised the main mechanism of CO poisoning and made a simplified modelling approach possible. The main features of CO poisoning were investigated by means of steady state polarisation, EIS and NFRA. The main characteristics of CO poisoning in the NFRA spectra can be used as a "fingerprint" for diagnostic purposes.

AB - Anodic CO poisoning of a PEMFC was analysed by nonlinear frequency response analysis (NFRA) in a differential H2/H2 cell. This special experimental setup excluded potential masking effects, emphasised the main mechanism of CO poisoning and made a simplified modelling approach possible. The main features of CO poisoning were investigated by means of steady state polarisation, EIS and NFRA. The main characteristics of CO poisoning in the NFRA spectra can be used as a "fingerprint" for diagnostic purposes.

KW - Carbon monoxide

KW - Higher order frequency response function

KW - Nonlinear frequency response analysis

KW - Polymer electrolyte membrane fuel cell

KW - Carbon monoxide

KW - Higher order frequency response function

KW - Nonlinear frequency response analysis

KW - Polymer electrolyte membrane fuel cell

UR - http://www.scopus.com/inward/record.url?scp=80053122916&partnerID=8YFLogxK

U2 - 10.1007/s10800-011-0298-8

DO - 10.1007/s10800-011-0298-8

M3 - Article

AN - SCOPUS:80053122916

VL - 41

SP - 1021

EP - 1032

JO - Journal of Applied Electrochemistry

JF - Journal of Applied Electrochemistry

SN - 0021-891X

IS - 9

ER -