New method of determining the mean curve of lightning impulses according to IEC 60060-1

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

Externe Organisationen

  • SINTEF Energy Research AS
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksIEE Conference Publication
Seiten1.74.S29-1.77.S21
Auflage467
PublikationsstatusVeröffentlicht - 1999
Veranstaltung1999 11th International Symposium on 'High Voltage Engineering' (ish99) - London, UK
Dauer: 23 Aug. 199927 Aug. 1999

Publikationsreihe

NameIEE Conference Publication
Nummer467
Band1
ISSN (Print)0537-9989

Abstract

In this contribution a new method for the determination of mean curves of lightning impulses is presented. The method is in accordance with the actual standard IEC 60060-1 and based on mathematical curve fitting using the Least Mean Square (LMS) error as quality criterion and the Gauss-Newton or the Levenberg-Marquardt algorithms in order to solve the nonlinear equations. The presented procedure reproduces measured lightning impulses in a more suitable way than conventional functions and is therefore able to determine mean curves of standard lightning impulses as well as of lightning impulses superimposed by oscillations or overshoots. A comparison of results obtained with the described method and other curve fittings by using the IEC-TDG and measured data produced by a special generating circuit shows that the new method is more favourable.

ASJC Scopus Sachgebiete

Zitieren

New method of determining the mean curve of lightning impulses according to IEC 60060-1. / Brede, Arne P.; Werle, Peter; Gockenbach, Ernst et al.
IEE Conference Publication. 467. Aufl. 1999. S. 1.74.S29-1.77.S21 (IEE Conference Publication; Band 1, Nr. 467).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Brede, AP, Werle, P, Gockenbach, E & Borsi, H 1999, New method of determining the mean curve of lightning impulses according to IEC 60060-1. in IEE Conference Publication. 467 Aufl., IEE Conference Publication, Nr. 467, Bd. 1, S. 1.74.S29-1.77.S21, 1999 11th International Symposium on 'High Voltage Engineering' (ish99), London, UK, 23 Aug. 1999.
Brede, A. P., Werle, P., Gockenbach, E., & Borsi, H. (1999). New method of determining the mean curve of lightning impulses according to IEC 60060-1. In IEE Conference Publication (467 Aufl., S. 1.74.S29-1.77.S21). (IEE Conference Publication; Band 1, Nr. 467).
Brede AP, Werle P, Gockenbach E, Borsi H. New method of determining the mean curve of lightning impulses according to IEC 60060-1. in IEE Conference Publication. 467 Aufl. 1999. S. 1.74.S29-1.77.S21. (IEE Conference Publication; 467).
Brede, Arne P. ; Werle, Peter ; Gockenbach, Ernst et al. / New method of determining the mean curve of lightning impulses according to IEC 60060-1. IEE Conference Publication. 467. Aufl. 1999. S. 1.74.S29-1.77.S21 (IEE Conference Publication; 467).
Download
@inproceedings{90a84344d9a3480287f4d76cb2676946,
title = "New method of determining the mean curve of lightning impulses according to IEC 60060-1",
abstract = "In this contribution a new method for the determination of mean curves of lightning impulses is presented. The method is in accordance with the actual standard IEC 60060-1 and based on mathematical curve fitting using the Least Mean Square (LMS) error as quality criterion and the Gauss-Newton or the Levenberg-Marquardt algorithms in order to solve the nonlinear equations. The presented procedure reproduces measured lightning impulses in a more suitable way than conventional functions and is therefore able to determine mean curves of standard lightning impulses as well as of lightning impulses superimposed by oscillations or overshoots. A comparison of results obtained with the described method and other curve fittings by using the IEC-TDG and measured data produced by a special generating circuit shows that the new method is more favourable.",
author = "Brede, {Arne P.} and Peter Werle and Ernst Gockenbach and H. Borsi",
note = "Copyright: Copyright 2007 Elsevier B.V., All rights reserved.; 1999 11th International Symposium on 'High Voltage Engineering' (ish99) ; Conference date: 23-08-1999 Through 27-08-1999",
year = "1999",
language = "English",
isbn = "0852967195",
series = "IEE Conference Publication",
number = "467",
pages = "1.74.S29--1.77.S21",
booktitle = "IEE Conference Publication",
edition = "467",

}

Download

TY - GEN

T1 - New method of determining the mean curve of lightning impulses according to IEC 60060-1

AU - Brede, Arne P.

AU - Werle, Peter

AU - Gockenbach, Ernst

AU - Borsi, H.

N1 - Copyright: Copyright 2007 Elsevier B.V., All rights reserved.

PY - 1999

Y1 - 1999

N2 - In this contribution a new method for the determination of mean curves of lightning impulses is presented. The method is in accordance with the actual standard IEC 60060-1 and based on mathematical curve fitting using the Least Mean Square (LMS) error as quality criterion and the Gauss-Newton or the Levenberg-Marquardt algorithms in order to solve the nonlinear equations. The presented procedure reproduces measured lightning impulses in a more suitable way than conventional functions and is therefore able to determine mean curves of standard lightning impulses as well as of lightning impulses superimposed by oscillations or overshoots. A comparison of results obtained with the described method and other curve fittings by using the IEC-TDG and measured data produced by a special generating circuit shows that the new method is more favourable.

AB - In this contribution a new method for the determination of mean curves of lightning impulses is presented. The method is in accordance with the actual standard IEC 60060-1 and based on mathematical curve fitting using the Least Mean Square (LMS) error as quality criterion and the Gauss-Newton or the Levenberg-Marquardt algorithms in order to solve the nonlinear equations. The presented procedure reproduces measured lightning impulses in a more suitable way than conventional functions and is therefore able to determine mean curves of standard lightning impulses as well as of lightning impulses superimposed by oscillations or overshoots. A comparison of results obtained with the described method and other curve fittings by using the IEC-TDG and measured data produced by a special generating circuit shows that the new method is more favourable.

UR - http://www.scopus.com/inward/record.url?scp=0033322372&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0033322372

SN - 0852967195

T3 - IEE Conference Publication

SP - 1.74.S29-1.77.S21

BT - IEE Conference Publication

T2 - 1999 11th International Symposium on 'High Voltage Engineering' (ish99)

Y2 - 23 August 1999 through 27 August 1999

ER -