Neutron beam separation with a macrobender

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

Externe Organisationen

  • Forschungszentrum Jülich
  • CILAS
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer021
Seiten (von - bis)654-656
Seitenumfang3
FachzeitschriftMeasurement science and technology
Jahrgang1
Ausgabenummer7
PublikationsstatusVeröffentlicht - 1990

Abstract

The technical set-up of a multislit bender (bent neutron guide) for the beam separation of a white cold neutron beam is presented. The transmission characteristics are discussed and it is shown that the transmission behaviour is dominated by reflectivity losses.

ASJC Scopus Sachgebiete

Zitieren

Neutron beam separation with a macrobender. / Schirmer, A.; Heitjans, P.; Faber, W. et al.
in: Measurement science and technology, Jahrgang 1, Nr. 7, 021, 1990, S. 654-656.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Schirmer A, Heitjans P, Faber W, Samuel FJ. Neutron beam separation with a macrobender. Measurement science and technology. 1990;1(7):654-656. 021. doi: 10.1088/0957-0233/1/7/021
Schirmer, A. ; Heitjans, P. ; Faber, W. et al. / Neutron beam separation with a macrobender. in: Measurement science and technology. 1990 ; Jahrgang 1, Nr. 7. S. 654-656.
Download
@article{13d1be267abb494fb3c3a9a4332cb800,
title = "Neutron beam separation with a macrobender",
abstract = "The technical set-up of a multislit bender (bent neutron guide) for the beam separation of a white cold neutron beam is presented. The transmission characteristics are discussed and it is shown that the transmission behaviour is dominated by reflectivity losses.",
author = "A. Schirmer and P. Heitjans and W. Faber and Samuel, {F. J.}",
year = "1990",
doi = "10.1088/0957-0233/1/7/021",
language = "English",
volume = "1",
pages = "654--656",
journal = "Measurement science and technology",
issn = "0957-0233",
publisher = "IOP Publishing Ltd.",
number = "7",

}

Download

TY - JOUR

T1 - Neutron beam separation with a macrobender

AU - Schirmer, A.

AU - Heitjans, P.

AU - Faber, W.

AU - Samuel, F. J.

PY - 1990

Y1 - 1990

N2 - The technical set-up of a multislit bender (bent neutron guide) for the beam separation of a white cold neutron beam is presented. The transmission characteristics are discussed and it is shown that the transmission behaviour is dominated by reflectivity losses.

AB - The technical set-up of a multislit bender (bent neutron guide) for the beam separation of a white cold neutron beam is presented. The transmission characteristics are discussed and it is shown that the transmission behaviour is dominated by reflectivity losses.

UR - http://www.scopus.com/inward/record.url?scp=0025460492&partnerID=8YFLogxK

U2 - 10.1088/0957-0233/1/7/021

DO - 10.1088/0957-0233/1/7/021

M3 - Article

AN - SCOPUS:0025460492

VL - 1

SP - 654

EP - 656

JO - Measurement science and technology

JF - Measurement science and technology

SN - 0957-0233

IS - 7

M1 - 021

ER -

Von denselben Autoren