Micromachined flame ionization detector and flame spectrometer

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

Externe Organisationen

  • Technische Universität Hamburg (TUHH)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksMicromachined Devices and Components V
ErscheinungsortBellingham
Herausgeber (Verlag)SPIE
Seiten238-245
Seitenumfang8
ISBN (Print)0-8194-3473-6
PublikationsstatusVeröffentlicht - 31 Aug. 1999
Extern publiziertJa
VeranstaltungSymposium on Micromachining and Microfabrication - Santa Clara, USA / Vereinigte Staaten
Dauer: 20 Sept. 199921 Sept. 1999

Publikationsreihe

NameProceedings of SPIE - The International Society for Optical Engineering
Herausgeber (Verlag)SPIE
Band3876
ISSN (Print)0277-786X

Abstract

In the course of a progressive miniaturization of complex measuring systems conventional flame ionization detectors and flame spectrometers are no longer competitive with the new generation of mobile analysis systems. This paper presents a micro flame ionization detector and flame spectrometer structured by methods of the microsystem technology. Main component is a micro burner unit with a reduced oxyhydrogen consumption to realize a stable miniature oxyhydrogen flame. The required oxyhydrogen is generated by electrolysis in a miniaturized electrolysis cell at low energy consumption. Thus the electrolyzer can be battery operated. Due to the reduced amount of explosive oxyhydrogen and the small dimensions of the gas supply micro flame analyzers have an unlimited mobility without safety restrictions and are easy to handle. Furthermore they have a high sensitivity and selectivity similar to conventional systems. Concentrations down to one ppm are detectable up to now with the micro flame ionization detector. The micro flame spectrometer is in its initial stage. First measurements to demonstrate the further possibilities of such a microsystem are presented.

ASJC Scopus Sachgebiete

Ziele für nachhaltige Entwicklung

Zitieren

Micromachined flame ionization detector and flame spectrometer. / Zimmermann, S.; Wischhusen, S.; Mueller, J.
Micromachined Devices and Components V. Bellingham: SPIE, 1999. S. 238-245 (Proceedings of SPIE - The International Society for Optical Engineering; Band 3876).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Zimmermann, S, Wischhusen, S & Mueller, J 1999, Micromachined flame ionization detector and flame spectrometer. in Micromachined Devices and Components V. Proceedings of SPIE - The International Society for Optical Engineering, Bd. 3876, SPIE, Bellingham, S. 238-245, Symposium on Micromachining and Microfabrication, Santa Clara, California, USA / Vereinigte Staaten, 20 Sept. 1999. https://doi.org/10.1117/12.360499
Zimmermann, S., Wischhusen, S., & Mueller, J. (1999). Micromachined flame ionization detector and flame spectrometer. In Micromachined Devices and Components V (S. 238-245). (Proceedings of SPIE - The International Society for Optical Engineering; Band 3876). SPIE. https://doi.org/10.1117/12.360499
Zimmermann S, Wischhusen S, Mueller J. Micromachined flame ionization detector and flame spectrometer. in Micromachined Devices and Components V. Bellingham: SPIE. 1999. S. 238-245. (Proceedings of SPIE - The International Society for Optical Engineering). doi: 10.1117/12.360499
Zimmermann, S. ; Wischhusen, S. ; Mueller, J. / Micromachined flame ionization detector and flame spectrometer. Micromachined Devices and Components V. Bellingham : SPIE, 1999. S. 238-245 (Proceedings of SPIE - The International Society for Optical Engineering).
Download
@inproceedings{303dcd780b4e4168af97b9c19209c7fe,
title = "Micromachined flame ionization detector and flame spectrometer",
abstract = "In the course of a progressive miniaturization of complex measuring systems conventional flame ionization detectors and flame spectrometers are no longer competitive with the new generation of mobile analysis systems. This paper presents a micro flame ionization detector and flame spectrometer structured by methods of the microsystem technology. Main component is a micro burner unit with a reduced oxyhydrogen consumption to realize a stable miniature oxyhydrogen flame. The required oxyhydrogen is generated by electrolysis in a miniaturized electrolysis cell at low energy consumption. Thus the electrolyzer can be battery operated. Due to the reduced amount of explosive oxyhydrogen and the small dimensions of the gas supply micro flame analyzers have an unlimited mobility without safety restrictions and are easy to handle. Furthermore they have a high sensitivity and selectivity similar to conventional systems. Concentrations down to one ppm are detectable up to now with the micro flame ionization detector. The micro flame spectrometer is in its initial stage. First measurements to demonstrate the further possibilities of such a microsystem are presented.",
author = "S. Zimmermann and S. Wischhusen and J. Mueller",
year = "1999",
month = aug,
day = "31",
doi = "10.1117/12.360499",
language = "English",
isbn = "0-8194-3473-6",
series = "Proceedings of SPIE - The International Society for Optical Engineering",
publisher = "SPIE",
pages = "238--245",
booktitle = "Micromachined Devices and Components V",
address = "United States",
note = "Symposium on Micromachining and Microfabrication ; Conference date: 20-09-1999 Through 21-09-1999",

}

Download

TY - GEN

T1 - Micromachined flame ionization detector and flame spectrometer

AU - Zimmermann, S.

AU - Wischhusen, S.

AU - Mueller, J.

PY - 1999/8/31

Y1 - 1999/8/31

N2 - In the course of a progressive miniaturization of complex measuring systems conventional flame ionization detectors and flame spectrometers are no longer competitive with the new generation of mobile analysis systems. This paper presents a micro flame ionization detector and flame spectrometer structured by methods of the microsystem technology. Main component is a micro burner unit with a reduced oxyhydrogen consumption to realize a stable miniature oxyhydrogen flame. The required oxyhydrogen is generated by electrolysis in a miniaturized electrolysis cell at low energy consumption. Thus the electrolyzer can be battery operated. Due to the reduced amount of explosive oxyhydrogen and the small dimensions of the gas supply micro flame analyzers have an unlimited mobility without safety restrictions and are easy to handle. Furthermore they have a high sensitivity and selectivity similar to conventional systems. Concentrations down to one ppm are detectable up to now with the micro flame ionization detector. The micro flame spectrometer is in its initial stage. First measurements to demonstrate the further possibilities of such a microsystem are presented.

AB - In the course of a progressive miniaturization of complex measuring systems conventional flame ionization detectors and flame spectrometers are no longer competitive with the new generation of mobile analysis systems. This paper presents a micro flame ionization detector and flame spectrometer structured by methods of the microsystem technology. Main component is a micro burner unit with a reduced oxyhydrogen consumption to realize a stable miniature oxyhydrogen flame. The required oxyhydrogen is generated by electrolysis in a miniaturized electrolysis cell at low energy consumption. Thus the electrolyzer can be battery operated. Due to the reduced amount of explosive oxyhydrogen and the small dimensions of the gas supply micro flame analyzers have an unlimited mobility without safety restrictions and are easy to handle. Furthermore they have a high sensitivity and selectivity similar to conventional systems. Concentrations down to one ppm are detectable up to now with the micro flame ionization detector. The micro flame spectrometer is in its initial stage. First measurements to demonstrate the further possibilities of such a microsystem are presented.

UR - http://www.scopus.com/inward/record.url?scp=0033309888&partnerID=8YFLogxK

U2 - 10.1117/12.360499

DO - 10.1117/12.360499

M3 - Conference contribution

AN - SCOPUS:0033309888

SN - 0-8194-3473-6

T3 - Proceedings of SPIE - The International Society for Optical Engineering

SP - 238

EP - 245

BT - Micromachined Devices and Components V

PB - SPIE

CY - Bellingham

T2 - Symposium on Micromachining and Microfabrication

Y2 - 20 September 1999 through 21 September 1999

ER -

Von denselben Autoren