Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 818-832 |
Seitenumfang | 15 |
Fachzeitschrift | Tissue Engineering - Part A |
Jahrgang | 28 |
Ausgabenummer | 19-20 |
Frühes Online-Datum | 26 Juli 2022 |
Publikationsstatus | Veröffentlicht - 13 Okt. 2022 |
Abstract
Generation of bioartificial blood vessels with a physiological three-layered wall architecture is a long pursued goal in vascular tissue engineering. While considerable advances have been made to resemble the physiological tunica intima and media morphology and function in bioartificial vessels, only very few studies have targeted the generation of a tunica adventitia, including its characteristic vascular network known as the vasa vasorum, which are essential for graft nutrition and integration. In healthy native blood vessels, capillary vasa vasorum are aligned longitudinally to the vessel axis. Thus, inducing longitudinal alignment of capillary tubes to generate a physiological tunica adventitia morphology and function may be advantageous in bioengineered vessels as well. In this study, we investigated the effect of two biomechanical stimulation parameters, longitudinal tension and physiological cyclic stretch, on tube alignment in capillary networks formed by self-assembly of human umbilical vein endothelial cells in tunica adventitia-equivalents of fibrin-based bioartificial blood vessels. Moreover, the effect of changes of the biomechanical environment on network remodeling after initial tube formation was analyzed. Both, longitudinal tension and cyclic stretch by pulsatile perfusion induced physiological capillary tube alignment parallel to the longitudinal vessel axis. This effect was even more pronounced when both biomechanical factors were applied simultaneously, which resulted in an alignment of 57.2 ± 5.2% within 5° of the main vessel axis. Opposed to that, a random tube orientation was observed in vessels incubated statically. Scanning electron microscopy showed that longitudinal tension also resulted in longitudinal alignment of fibrin fibrils, which may function as a guidance structure for directed capillary tube formation. Moreover, existing microvascular networks showed distinct remodeling in response to addition or withdrawal of mechanical stimulation with corresponding increase or decrease of the degree of alignment. With longitudinal tension and cyclic stretch, we identified two mechanical stimuli that facilitate the generation of a prevascularized tunica adventitia-equivalent with physiological tube alignment in bioartificial vascular grafts. Fibrin-based bioartificial vessels represent a promising regenerative approach to generate vascular grafts with superior biocompatibility and hemocompatibility compared to currently available synthetic graft materials. Precapillarization of bioartificial vascular grafts may improve nutrition of the vessel wall and integration of the graft into the target organism's microvasculature. In native vessels, physiological vasa vasorum alignment is pivotal for proper function of the tunica adventitia. Thus, it is necessary to induce longitudinal capillary alignment in the tunica adventitia of bioengineered vessels as well to secure long-term graft patency and function. This alignment can be reliably achieved by controlled biomechanical stimulation in vitro.
ASJC Scopus Sachgebiete
- Chemische Verfahrenstechnik (insg.)
- Bioengineering
- Biochemie, Genetik und Molekularbiologie (insg.)
- Biochemie
- Werkstoffwissenschaften (insg.)
- Biomaterialien
- Ingenieurwesen (insg.)
- Biomedizintechnik
Ziele für nachhaltige Entwicklung
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Tissue Engineering - Part A, Jahrgang 28, Nr. 19-20, 13.10.2022, S. 818-832.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Mechanical Stimulation Induces Vasa Vasorum Capillary Alignment in a Fibrin-Based Tunica Adventitia
AU - Helms, Florian
AU - Zippusch, Sarah
AU - Aper, Thomas
AU - Kalies, Stefan
AU - Heisterkamp, Alexander
AU - Haverich, Axel
AU - Böer, Ulrike
AU - Wilhelmi, Mathias
N1 - Funding Information: This work was funded by the German Society for Implant Research and Development (funding title: ‘‘Vascularization of bioartificial implants 2017–2020’’) and the VHV-Foundation Hannover, Germany.
PY - 2022/10/13
Y1 - 2022/10/13
N2 - Generation of bioartificial blood vessels with a physiological three-layered wall architecture is a long pursued goal in vascular tissue engineering. While considerable advances have been made to resemble the physiological tunica intima and media morphology and function in bioartificial vessels, only very few studies have targeted the generation of a tunica adventitia, including its characteristic vascular network known as the vasa vasorum, which are essential for graft nutrition and integration. In healthy native blood vessels, capillary vasa vasorum are aligned longitudinally to the vessel axis. Thus, inducing longitudinal alignment of capillary tubes to generate a physiological tunica adventitia morphology and function may be advantageous in bioengineered vessels as well. In this study, we investigated the effect of two biomechanical stimulation parameters, longitudinal tension and physiological cyclic stretch, on tube alignment in capillary networks formed by self-assembly of human umbilical vein endothelial cells in tunica adventitia-equivalents of fibrin-based bioartificial blood vessels. Moreover, the effect of changes of the biomechanical environment on network remodeling after initial tube formation was analyzed. Both, longitudinal tension and cyclic stretch by pulsatile perfusion induced physiological capillary tube alignment parallel to the longitudinal vessel axis. This effect was even more pronounced when both biomechanical factors were applied simultaneously, which resulted in an alignment of 57.2 ± 5.2% within 5° of the main vessel axis. Opposed to that, a random tube orientation was observed in vessels incubated statically. Scanning electron microscopy showed that longitudinal tension also resulted in longitudinal alignment of fibrin fibrils, which may function as a guidance structure for directed capillary tube formation. Moreover, existing microvascular networks showed distinct remodeling in response to addition or withdrawal of mechanical stimulation with corresponding increase or decrease of the degree of alignment. With longitudinal tension and cyclic stretch, we identified two mechanical stimuli that facilitate the generation of a prevascularized tunica adventitia-equivalent with physiological tube alignment in bioartificial vascular grafts. Fibrin-based bioartificial vessels represent a promising regenerative approach to generate vascular grafts with superior biocompatibility and hemocompatibility compared to currently available synthetic graft materials. Precapillarization of bioartificial vascular grafts may improve nutrition of the vessel wall and integration of the graft into the target organism's microvasculature. In native vessels, physiological vasa vasorum alignment is pivotal for proper function of the tunica adventitia. Thus, it is necessary to induce longitudinal capillary alignment in the tunica adventitia of bioengineered vessels as well to secure long-term graft patency and function. This alignment can be reliably achieved by controlled biomechanical stimulation in vitro.
AB - Generation of bioartificial blood vessels with a physiological three-layered wall architecture is a long pursued goal in vascular tissue engineering. While considerable advances have been made to resemble the physiological tunica intima and media morphology and function in bioartificial vessels, only very few studies have targeted the generation of a tunica adventitia, including its characteristic vascular network known as the vasa vasorum, which are essential for graft nutrition and integration. In healthy native blood vessels, capillary vasa vasorum are aligned longitudinally to the vessel axis. Thus, inducing longitudinal alignment of capillary tubes to generate a physiological tunica adventitia morphology and function may be advantageous in bioengineered vessels as well. In this study, we investigated the effect of two biomechanical stimulation parameters, longitudinal tension and physiological cyclic stretch, on tube alignment in capillary networks formed by self-assembly of human umbilical vein endothelial cells in tunica adventitia-equivalents of fibrin-based bioartificial blood vessels. Moreover, the effect of changes of the biomechanical environment on network remodeling after initial tube formation was analyzed. Both, longitudinal tension and cyclic stretch by pulsatile perfusion induced physiological capillary tube alignment parallel to the longitudinal vessel axis. This effect was even more pronounced when both biomechanical factors were applied simultaneously, which resulted in an alignment of 57.2 ± 5.2% within 5° of the main vessel axis. Opposed to that, a random tube orientation was observed in vessels incubated statically. Scanning electron microscopy showed that longitudinal tension also resulted in longitudinal alignment of fibrin fibrils, which may function as a guidance structure for directed capillary tube formation. Moreover, existing microvascular networks showed distinct remodeling in response to addition or withdrawal of mechanical stimulation with corresponding increase or decrease of the degree of alignment. With longitudinal tension and cyclic stretch, we identified two mechanical stimuli that facilitate the generation of a prevascularized tunica adventitia-equivalent with physiological tube alignment in bioartificial vascular grafts. Fibrin-based bioartificial vessels represent a promising regenerative approach to generate vascular grafts with superior biocompatibility and hemocompatibility compared to currently available synthetic graft materials. Precapillarization of bioartificial vascular grafts may improve nutrition of the vessel wall and integration of the graft into the target organism's microvasculature. In native vessels, physiological vasa vasorum alignment is pivotal for proper function of the tunica adventitia. Thus, it is necessary to induce longitudinal capillary alignment in the tunica adventitia of bioengineered vessels as well to secure long-term graft patency and function. This alignment can be reliably achieved by controlled biomechanical stimulation in vitro.
KW - bioartificial vessels
KW - capillary networks
KW - mechanical stimulation
KW - vasa vasorum
KW - vascular grafts
KW - vascular tissue engineering
UR - http://www.scopus.com/inward/record.url?scp=85140416509&partnerID=8YFLogxK
U2 - 10.1089/ten.tea.2022.0042
DO - 10.1089/ten.tea.2022.0042
M3 - Article
C2 - 35611972
AN - SCOPUS:85140416509
VL - 28
SP - 818
EP - 832
JO - Tissue Engineering - Part A
JF - Tissue Engineering - Part A
SN - 1937-3341
IS - 19-20
ER -