Abstract

Magnetic nanoparticles (MNPs) are of great interest for industrial and medical applications. Therefore, the properties of the particles have to be well controlled. Several magnetic measurement schemes have been developed in order to determine particle parameters such as size distribution and structural properties. In general, systems are designed either for the analysis of large amounts of MNP (蠑 1000) or for single particle investigation. Up to now, the region in between has been less studied. However, small and well defined amounts of MNPs are of high interest, e.g. for the systematic investigation of particle-particle interactions. In this paper, we present a method using electron beam lithographic preparation of small amounts of MNPs directly on a self-compensating high-temperature superconducting quantum interference device (SQUID) with micrometer dimensions which is insensitive to homogeneous fields and first order gradients but very sensitive to internal magnetic dipole fields. Magnetorelaxometry (MRX) measurements were carried out at 77 K sample temperature in a magnetically shielded room in order to analyze the dynamic behavior of MNP samples and to evaluate the detection limit of our SQUID sensors. Calculations based on the magnetic moment superposition model (MSM) and finite element simulations (FEM) indicate that the MNP samples can be fabricated in a well-defined way by the presented method. Based on MRX measurements of a sample with 200 single-core magnetite MNPs with core diameters of 12 nm, we estimate the detection limit of our SQUID MRX setup as 70 MNPs.

ASJC Scopus Sachgebiete

Zitieren

Magnetorelaxometry of few Fe3O4 nanoparticles at 77 K employing a self-compensated SQUID magnetometer. / Guillaume, A.; Scholtyssek, J.M.; Lak, A. et al.
in: Journal of Magnetism and Magnetic Materials, Jahrgang 408, 15.06.2016, S. 46-50.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Guillaume A, Scholtyssek JM, Lak A, Kassner A, Ludwig F, Schilling M. Magnetorelaxometry of few Fe3O4 nanoparticles at 77 K employing a self-compensated SQUID magnetometer. Journal of Magnetism and Magnetic Materials. 2016 Jun 15;408:46-50. doi: 10.1016/j.jmmm.2016.01.071
Download
@article{5502a21d0e6f49a59b30b3a8a44f4526,
title = "Magnetorelaxometry of few Fe3O4 nanoparticles at 77 K employing a self-compensated SQUID magnetometer",
abstract = "Magnetic nanoparticles (MNPs) are of great interest for industrial and medical applications. Therefore, the properties of the particles have to be well controlled. Several magnetic measurement schemes have been developed in order to determine particle parameters such as size distribution and structural properties. In general, systems are designed either for the analysis of large amounts of MNP (蠑 1000) or for single particle investigation. Up to now, the region in between has been less studied. However, small and well defined amounts of MNPs are of high interest, e.g. for the systematic investigation of particle-particle interactions. In this paper, we present a method using electron beam lithographic preparation of small amounts of MNPs directly on a self-compensating high-temperature superconducting quantum interference device (SQUID) with micrometer dimensions which is insensitive to homogeneous fields and first order gradients but very sensitive to internal magnetic dipole fields. Magnetorelaxometry (MRX) measurements were carried out at 77 K sample temperature in a magnetically shielded room in order to analyze the dynamic behavior of MNP samples and to evaluate the detection limit of our SQUID sensors. Calculations based on the magnetic moment superposition model (MSM) and finite element simulations (FEM) indicate that the MNP samples can be fabricated in a well-defined way by the presented method. Based on MRX measurements of a sample with 200 single-core magnetite MNPs with core diameters of 12 nm, we estimate the detection limit of our SQUID MRX setup as 70 MNPs.",
keywords = "Electron-beam lithography, FEM, Magnetic nanoparticles, Magnetorelaxometry, Self-compensated SQUID",
author = "A. Guillaume and J.M. Scholtyssek and A. Lak and A. Kassner and F. Ludwig and M. Schilling",
note = "Publisher Copyright: {\textcopyright} 2016 Elsevier B.V. All rights reserved.",
year = "2016",
month = jun,
day = "15",
doi = "10.1016/j.jmmm.2016.01.071",
language = "English",
volume = "408",
pages = "46--50",
journal = "Journal of Magnetism and Magnetic Materials",
issn = "0304-8853",
publisher = "Elsevier",

}

Download

TY - JOUR

T1 - Magnetorelaxometry of few Fe3O4 nanoparticles at 77 K employing a self-compensated SQUID magnetometer

AU - Guillaume, A.

AU - Scholtyssek, J.M.

AU - Lak, A.

AU - Kassner, A.

AU - Ludwig, F.

AU - Schilling, M.

N1 - Publisher Copyright: © 2016 Elsevier B.V. All rights reserved.

PY - 2016/6/15

Y1 - 2016/6/15

N2 - Magnetic nanoparticles (MNPs) are of great interest for industrial and medical applications. Therefore, the properties of the particles have to be well controlled. Several magnetic measurement schemes have been developed in order to determine particle parameters such as size distribution and structural properties. In general, systems are designed either for the analysis of large amounts of MNP (蠑 1000) or for single particle investigation. Up to now, the region in between has been less studied. However, small and well defined amounts of MNPs are of high interest, e.g. for the systematic investigation of particle-particle interactions. In this paper, we present a method using electron beam lithographic preparation of small amounts of MNPs directly on a self-compensating high-temperature superconducting quantum interference device (SQUID) with micrometer dimensions which is insensitive to homogeneous fields and first order gradients but very sensitive to internal magnetic dipole fields. Magnetorelaxometry (MRX) measurements were carried out at 77 K sample temperature in a magnetically shielded room in order to analyze the dynamic behavior of MNP samples and to evaluate the detection limit of our SQUID sensors. Calculations based on the magnetic moment superposition model (MSM) and finite element simulations (FEM) indicate that the MNP samples can be fabricated in a well-defined way by the presented method. Based on MRX measurements of a sample with 200 single-core magnetite MNPs with core diameters of 12 nm, we estimate the detection limit of our SQUID MRX setup as 70 MNPs.

AB - Magnetic nanoparticles (MNPs) are of great interest for industrial and medical applications. Therefore, the properties of the particles have to be well controlled. Several magnetic measurement schemes have been developed in order to determine particle parameters such as size distribution and structural properties. In general, systems are designed either for the analysis of large amounts of MNP (蠑 1000) or for single particle investigation. Up to now, the region in between has been less studied. However, small and well defined amounts of MNPs are of high interest, e.g. for the systematic investigation of particle-particle interactions. In this paper, we present a method using electron beam lithographic preparation of small amounts of MNPs directly on a self-compensating high-temperature superconducting quantum interference device (SQUID) with micrometer dimensions which is insensitive to homogeneous fields and first order gradients but very sensitive to internal magnetic dipole fields. Magnetorelaxometry (MRX) measurements were carried out at 77 K sample temperature in a magnetically shielded room in order to analyze the dynamic behavior of MNP samples and to evaluate the detection limit of our SQUID sensors. Calculations based on the magnetic moment superposition model (MSM) and finite element simulations (FEM) indicate that the MNP samples can be fabricated in a well-defined way by the presented method. Based on MRX measurements of a sample with 200 single-core magnetite MNPs with core diameters of 12 nm, we estimate the detection limit of our SQUID MRX setup as 70 MNPs.

KW - Electron-beam lithography

KW - FEM

KW - Magnetic nanoparticles

KW - Magnetorelaxometry

KW - Self-compensated SQUID

UR - http://www.scopus.com/inward/record.url?scp=84958211800&partnerID=8YFLogxK

U2 - 10.1016/j.jmmm.2016.01.071

DO - 10.1016/j.jmmm.2016.01.071

M3 - Article

VL - 408

SP - 46

EP - 50

JO - Journal of Magnetism and Magnetic Materials

JF - Journal of Magnetism and Magnetic Materials

SN - 0304-8853

ER -

Von denselben Autoren