Details
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 133-144 |
Seitenumfang | 12 |
Fachzeitschrift | Applied Physics B: Lasers and Optics |
Jahrgang | 92 |
Ausgabenummer | 2 |
Frühes Online-Datum | 27 Juni 2008 |
Publikationsstatus | Veröffentlicht - Aug. 2008 |
Extern publiziert | Ja |
Abstract
A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of 1.4×10 -8g at 1 s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the ac acceleration signal measured by a low noise seismometer.
ASJC Scopus Sachgebiete
- Physik und Astronomie (insg.)
- Physik und Astronomie (sonstige)
- Physik und Astronomie (insg.)
- Allgemeine Physik und Astronomie
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: Applied Physics B: Lasers and Optics, Jahrgang 92, Nr. 2, 08.2008, S. 133-144.
Publikation: Beitrag in Fachzeitschrift › Artikel › Forschung › Peer-Review
}
TY - JOUR
T1 - Limits to the sensitivity of a low noise compact atomic gravimeter
AU - Le Gouët, J.
AU - Mehlstäubler, T. E.
AU - Kim, J.
AU - Merlet, S.
AU - Clairon, A.
AU - Landragin, A.
AU - Dos Santos, F. Pereira
PY - 2008/8
Y1 - 2008/8
N2 - A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of 1.4×10 -8g at 1 s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the ac acceleration signal measured by a low noise seismometer.
AB - A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of 1.4×10 -8g at 1 s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the ac acceleration signal measured by a low noise seismometer.
UR - http://www.scopus.com/inward/record.url?scp=47749151424&partnerID=8YFLogxK
U2 - 10.1007/s00340-008-3088-1
DO - 10.1007/s00340-008-3088-1
M3 - Article
AN - SCOPUS:47749151424
VL - 92
SP - 133
EP - 144
JO - Applied Physics B: Lasers and Optics
JF - Applied Physics B: Lasers and Optics
SN - 0946-2171
IS - 2