Abstract

Estimating pile group efficiency for open-ended steel piles in small group arrangements is a challenging task for designers. This paper reports on the large-scale experimental campaign performed for the BorWin gamma offshore converter platform, which involved single piles and two-pile group systems on a scale of 1:10. The experimental works included installation, dynamic end-of-driving tests, dynamic restrike tests, and static load tests of a single pile and a pair of two-pile groups in densely compacted, artificially prepared homogeneous sand. The cone penetration test (CPT) profiles and the blow counts confirmed that the foundation systems are comparable to each other. The experimental results of the single pile system were compared with conventional design methods. Such comparison indicated that CPT-based methods and load-transfer methods are applicable at the considered model scale. The bearing capacity prediction obtained via the Case Pile Wave Analysis Program (CAPWAP) method is conservative with respect to the static capacity. A consistent setup effect can be detected by analyzing the complete dynamic loading session. The pile group efficiency for the given foundation system was found to be less than 1.0 at both very small and very large soil strains, while it equaled 1.0 at failure.

ASJC Scopus Sachgebiete

Zitieren

Large-scale model tests of a single pile and two-pile groups for an offshore platform in sand. / Foglia, Aligi; Abdel-Rahman, Khalid; Wisotzki, Elmar et al.
in: Canadian geotechnical journal, Jahrgang 58, Nr. 12, 2021, S. 1825-1838.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Foglia A, Abdel-Rahman K, Wisotzki E, Quiroz T, Achmus M. Large-scale model tests of a single pile and two-pile groups for an offshore platform in sand. Canadian geotechnical journal. 2021;58(12):1825-1838. Epub 2021 Feb 2. doi: 10.1139/cgj-2020-0224
Download
@article{92bed1600a7e44d18dbf2e11acd3f7b5,
title = "Large-scale model tests of a single pile and two-pile groups for an offshore platform in sand",
abstract = "Estimating pile group efficiency for open-ended steel piles in small group arrangements is a challenging task for designers. This paper reports on the large-scale experimental campaign performed for the BorWin gamma offshore converter platform, which involved single piles and two-pile group systems on a scale of 1:10. The experimental works included installation, dynamic end-of-driving tests, dynamic restrike tests, and static load tests of a single pile and a pair of two-pile groups in densely compacted, artificially prepared homogeneous sand. The cone penetration test (CPT) profiles and the blow counts confirmed that the foundation systems are comparable to each other. The experimental results of the single pile system were compared with conventional design methods. Such comparison indicated that CPT-based methods and load-transfer methods are applicable at the considered model scale. The bearing capacity prediction obtained via the Case Pile Wave Analysis Program (CAPWAP) method is conservative with respect to the static capacity. A consistent setup effect can be detected by analyzing the complete dynamic loading session. The pile group efficiency for the given foundation system was found to be less than 1.0 at both very small and very large soil strains, while it equaled 1.0 at failure.",
keywords = "Large-scale model tests, Offshore platform, Pile group",
author = "Aligi Foglia and Khalid Abdel-Rahman and Elmar Wisotzki and Tulio Quiroz and Martin Achmus",
year = "2021",
doi = "10.1139/cgj-2020-0224",
language = "English",
volume = "58",
pages = "1825--1838",
journal = "Canadian geotechnical journal",
issn = "0008-3674",
publisher = "National Research Council of Canada",
number = "12",

}

Download

TY - JOUR

T1 - Large-scale model tests of a single pile and two-pile groups for an offshore platform in sand

AU - Foglia, Aligi

AU - Abdel-Rahman, Khalid

AU - Wisotzki, Elmar

AU - Quiroz, Tulio

AU - Achmus, Martin

PY - 2021

Y1 - 2021

N2 - Estimating pile group efficiency for open-ended steel piles in small group arrangements is a challenging task for designers. This paper reports on the large-scale experimental campaign performed for the BorWin gamma offshore converter platform, which involved single piles and two-pile group systems on a scale of 1:10. The experimental works included installation, dynamic end-of-driving tests, dynamic restrike tests, and static load tests of a single pile and a pair of two-pile groups in densely compacted, artificially prepared homogeneous sand. The cone penetration test (CPT) profiles and the blow counts confirmed that the foundation systems are comparable to each other. The experimental results of the single pile system were compared with conventional design methods. Such comparison indicated that CPT-based methods and load-transfer methods are applicable at the considered model scale. The bearing capacity prediction obtained via the Case Pile Wave Analysis Program (CAPWAP) method is conservative with respect to the static capacity. A consistent setup effect can be detected by analyzing the complete dynamic loading session. The pile group efficiency for the given foundation system was found to be less than 1.0 at both very small and very large soil strains, while it equaled 1.0 at failure.

AB - Estimating pile group efficiency for open-ended steel piles in small group arrangements is a challenging task for designers. This paper reports on the large-scale experimental campaign performed for the BorWin gamma offshore converter platform, which involved single piles and two-pile group systems on a scale of 1:10. The experimental works included installation, dynamic end-of-driving tests, dynamic restrike tests, and static load tests of a single pile and a pair of two-pile groups in densely compacted, artificially prepared homogeneous sand. The cone penetration test (CPT) profiles and the blow counts confirmed that the foundation systems are comparable to each other. The experimental results of the single pile system were compared with conventional design methods. Such comparison indicated that CPT-based methods and load-transfer methods are applicable at the considered model scale. The bearing capacity prediction obtained via the Case Pile Wave Analysis Program (CAPWAP) method is conservative with respect to the static capacity. A consistent setup effect can be detected by analyzing the complete dynamic loading session. The pile group efficiency for the given foundation system was found to be less than 1.0 at both very small and very large soil strains, while it equaled 1.0 at failure.

KW - Large-scale model tests

KW - Offshore platform

KW - Pile group

UR - http://www.scopus.com/inward/record.url?scp=85120887540&partnerID=8YFLogxK