Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

  • Sahand Seifi
  • Peter Werle
  • Hossein Mohseni
  • Amir Abbas Shayegani Akmal
  • Younes Norouzi

Externe Organisationen

  • University of Tehran
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksVDE-Fachtagung Hochspannungstechnik 2018
Seiten314-319
Seitenumfang6
ISBN (elektronisch)9783800748075
PublikationsstatusVeröffentlicht - 2018
VeranstaltungVDE-Fachtagung Hochspannungstechnik 2018 - VDE Conference on High Voltage Technology 2018 - Berlin, Deutschland
Dauer: 12 Nov. 201814 Nov. 2018

Abstract

Frequency Response Analysis (FRA) measurements on a transformer is an effective method to detect deformation of the windings. Various publications have attempted to use this method in different ways to detect or localize the deformation. Some of them have tried to obtain a detailed model of the winding using the FRA measurement to assess the deformation. On the other hand, the detailed model could also be used for finding the sectional winding transfer functions (SWTFs), which were needed for electrical PD localization methods. Although for both applications the detailed model of windings is necessary, the influence of different parameters of the detailed model on FRA measurements could be different and their importance are not same. There are various connections for FRA measurements, which are more sensitive to some specific parameters. Hence, a comprehensive study on the sensitivity of different parameters of the transformer detailed model is conducted in this contribution.

ASJC Scopus Sachgebiete

Zitieren

Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements. / Seifi, Sahand; Werle, Peter; Mohseni, Hossein et al.
VDE-Fachtagung Hochspannungstechnik 2018. 2018. S. 314-319.

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Seifi, S, Werle, P, Mohseni, H, Shayegani Akmal, AA & Norouzi, Y 2018, Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements. in VDE-Fachtagung Hochspannungstechnik 2018. S. 314-319, VDE-Fachtagung Hochspannungstechnik 2018 - VDE Conference on High Voltage Technology 2018, Berlin, Deutschland, 12 Nov. 2018.
Seifi, S., Werle, P., Mohseni, H., Shayegani Akmal, A. A., & Norouzi, Y. (2018). Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements. In VDE-Fachtagung Hochspannungstechnik 2018 (S. 314-319)
Seifi S, Werle P, Mohseni H, Shayegani Akmal AA, Norouzi Y. Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements. in VDE-Fachtagung Hochspannungstechnik 2018. 2018. S. 314-319
Seifi, Sahand ; Werle, Peter ; Mohseni, Hossein et al. / Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements. VDE-Fachtagung Hochspannungstechnik 2018. 2018. S. 314-319
Download
@inproceedings{22c8bc093cc940b8b6371525b4d5584a,
title = "Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements",
abstract = "Frequency Response Analysis (FRA) measurements on a transformer is an effective method to detect deformation of the windings. Various publications have attempted to use this method in different ways to detect or localize the deformation. Some of them have tried to obtain a detailed model of the winding using the FRA measurement to assess the deformation. On the other hand, the detailed model could also be used for finding the sectional winding transfer functions (SWTFs), which were needed for electrical PD localization methods. Although for both applications the detailed model of windings is necessary, the influence of different parameters of the detailed model on FRA measurements could be different and their importance are not same. There are various connections for FRA measurements, which are more sensitive to some specific parameters. Hence, a comprehensive study on the sensitivity of different parameters of the transformer detailed model is conducted in this contribution.",
author = "Sahand Seifi and Peter Werle and Hossein Mohseni and {Shayegani Akmal}, {Amir Abbas} and Younes Norouzi",
note = "Publisher Copyright: {\textcopyright} VDE VERLAG GMBH · Berlin · Offenbach Copyright: Copyright 2020 Elsevier B.V., All rights reserved.; VDE-Fachtagung Hochspannungstechnik 2018 - VDE Conference on High Voltage Technology 2018 ; Conference date: 12-11-2018 Through 14-11-2018",
year = "2018",
language = "English",
pages = "314--319",
booktitle = "VDE-Fachtagung Hochspannungstechnik 2018",

}

Download

TY - GEN

T1 - Investigation of a Special Transformer Winding Model for the Interpretation of FRA Measurements

AU - Seifi, Sahand

AU - Werle, Peter

AU - Mohseni, Hossein

AU - Shayegani Akmal, Amir Abbas

AU - Norouzi, Younes

N1 - Publisher Copyright: © VDE VERLAG GMBH · Berlin · Offenbach Copyright: Copyright 2020 Elsevier B.V., All rights reserved.

PY - 2018

Y1 - 2018

N2 - Frequency Response Analysis (FRA) measurements on a transformer is an effective method to detect deformation of the windings. Various publications have attempted to use this method in different ways to detect or localize the deformation. Some of them have tried to obtain a detailed model of the winding using the FRA measurement to assess the deformation. On the other hand, the detailed model could also be used for finding the sectional winding transfer functions (SWTFs), which were needed for electrical PD localization methods. Although for both applications the detailed model of windings is necessary, the influence of different parameters of the detailed model on FRA measurements could be different and their importance are not same. There are various connections for FRA measurements, which are more sensitive to some specific parameters. Hence, a comprehensive study on the sensitivity of different parameters of the transformer detailed model is conducted in this contribution.

AB - Frequency Response Analysis (FRA) measurements on a transformer is an effective method to detect deformation of the windings. Various publications have attempted to use this method in different ways to detect or localize the deformation. Some of them have tried to obtain a detailed model of the winding using the FRA measurement to assess the deformation. On the other hand, the detailed model could also be used for finding the sectional winding transfer functions (SWTFs), which were needed for electrical PD localization methods. Although for both applications the detailed model of windings is necessary, the influence of different parameters of the detailed model on FRA measurements could be different and their importance are not same. There are various connections for FRA measurements, which are more sensitive to some specific parameters. Hence, a comprehensive study on the sensitivity of different parameters of the transformer detailed model is conducted in this contribution.

UR - http://www.scopus.com/inward/record.url?scp=85096746495&partnerID=8YFLogxK

M3 - Conference contribution

SP - 314

EP - 319

BT - VDE-Fachtagung Hochspannungstechnik 2018

T2 - VDE-Fachtagung Hochspannungstechnik 2018 - VDE Conference on High Voltage Technology 2018

Y2 - 12 November 2018 through 14 November 2018

ER -