Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • M. Faïez Ktata
  • Uwe Arz
  • Hartmut Grabinski
  • Helmut Fischer

Externe Organisationen

  • Infineon Technologies AG
  • Physikalisch-Technische Bundesanstalt (PTB)
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)152-159
Seitenumfang8
FachzeitschriftIEEE Transactions on Advanced Packaging
Jahrgang28
Ausgabenummer2
PublikationsstatusVeröffentlicht - Mai 2005

Abstract

The impact of the ground line position on the line parameters of signal interconnects built in a 110-nm CMOS technology is investigated in the presence of a conductive substrate. Characteristic line parameters obtained from simulations are validated with two-port network analyzer measurements of specially designed test structures in a frequency range up to 50 GHz. In addition, the influence of the ground line position on time-domain signals in product-related bus systems is explored. It is shown that the impact of substrate effects on the line parameters, and consequently on the signal shape in the time domain, strongly depends on the relative position of the ground line with respect to the signal lines and, as expected, on the length of the line system. We show that for short on-chip bus systems (shorter than 2 mm), the influence of the ground line positioning on time-domain signals is negligible. However, for long bus systems (e.g., 5 mm), this influence becomes significant and can no longer be neglected.

ASJC Scopus Sachgebiete

Zitieren

Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain. / Ktata, M. Faïez; Arz, Uwe; Grabinski, Hartmut et al.
in: IEEE Transactions on Advanced Packaging, Jahrgang 28, Nr. 2, 05.2005, S. 152-159.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Ktata, MF, Arz, U, Grabinski, H & Fischer, H 2005, 'Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain', IEEE Transactions on Advanced Packaging, Jg. 28, Nr. 2, S. 152-159. https://doi.org/10.1109/TADVP.2005.846946
Ktata, M. F., Arz, U., Grabinski, H., & Fischer, H. (2005). Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain. IEEE Transactions on Advanced Packaging, 28(2), 152-159. https://doi.org/10.1109/TADVP.2005.846946
Ktata MF, Arz U, Grabinski H, Fischer H. Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain. IEEE Transactions on Advanced Packaging. 2005 Mai;28(2):152-159. doi: 10.1109/TADVP.2005.846946
Ktata, M. Faïez ; Arz, Uwe ; Grabinski, Hartmut et al. / Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain. in: IEEE Transactions on Advanced Packaging. 2005 ; Jahrgang 28, Nr. 2. S. 152-159.
Download
@article{3dba4cca27e940d3820c8a27e0ea350a,
title = "Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain",
abstract = "The impact of the ground line position on the line parameters of signal interconnects built in a 110-nm CMOS technology is investigated in the presence of a conductive substrate. Characteristic line parameters obtained from simulations are validated with two-port network analyzer measurements of specially designed test structures in a frequency range up to 50 GHz. In addition, the influence of the ground line position on time-domain signals in product-related bus systems is explored. It is shown that the impact of substrate effects on the line parameters, and consequently on the signal shape in the time domain, strongly depends on the relative position of the ground line with respect to the signal lines and, as expected, on the length of the line system. We show that for short on-chip bus systems (shorter than 2 mm), the influence of the ground line positioning on time-domain signals is negligible. However, for long bus systems (e.g., 5 mm), this influence becomes significant and can no longer be neglected.",
keywords = "110-nm CMOS technology, Parameter extraction, Proximity effect, S-parameter measurement, Signal integrity, Substrate effects, Time-domain simulations",
author = "Ktata, {M. Fa{\"i}ez} and Uwe Arz and Hartmut Grabinski and Helmut Fischer",
year = "2005",
month = may,
doi = "10.1109/TADVP.2005.846946",
language = "English",
volume = "28",
pages = "152--159",
number = "2",

}

Download

TY - JOUR

T1 - Influence of the ground line position on the signal integrity of product-related interconnects in the frequency and time domain

AU - Ktata, M. Faïez

AU - Arz, Uwe

AU - Grabinski, Hartmut

AU - Fischer, Helmut

PY - 2005/5

Y1 - 2005/5

N2 - The impact of the ground line position on the line parameters of signal interconnects built in a 110-nm CMOS technology is investigated in the presence of a conductive substrate. Characteristic line parameters obtained from simulations are validated with two-port network analyzer measurements of specially designed test structures in a frequency range up to 50 GHz. In addition, the influence of the ground line position on time-domain signals in product-related bus systems is explored. It is shown that the impact of substrate effects on the line parameters, and consequently on the signal shape in the time domain, strongly depends on the relative position of the ground line with respect to the signal lines and, as expected, on the length of the line system. We show that for short on-chip bus systems (shorter than 2 mm), the influence of the ground line positioning on time-domain signals is negligible. However, for long bus systems (e.g., 5 mm), this influence becomes significant and can no longer be neglected.

AB - The impact of the ground line position on the line parameters of signal interconnects built in a 110-nm CMOS technology is investigated in the presence of a conductive substrate. Characteristic line parameters obtained from simulations are validated with two-port network analyzer measurements of specially designed test structures in a frequency range up to 50 GHz. In addition, the influence of the ground line position on time-domain signals in product-related bus systems is explored. It is shown that the impact of substrate effects on the line parameters, and consequently on the signal shape in the time domain, strongly depends on the relative position of the ground line with respect to the signal lines and, as expected, on the length of the line system. We show that for short on-chip bus systems (shorter than 2 mm), the influence of the ground line positioning on time-domain signals is negligible. However, for long bus systems (e.g., 5 mm), this influence becomes significant and can no longer be neglected.

KW - 110-nm CMOS technology

KW - Parameter extraction

KW - Proximity effect

KW - S-parameter measurement

KW - Signal integrity

KW - Substrate effects

KW - Time-domain simulations

UR - http://www.scopus.com/inward/record.url?scp=20344385018&partnerID=8YFLogxK

U2 - 10.1109/TADVP.2005.846946

DO - 10.1109/TADVP.2005.846946

M3 - Article

AN - SCOPUS:20344385018

VL - 28

SP - 152

EP - 159

JO - IEEE Transactions on Advanced Packaging

JF - IEEE Transactions on Advanced Packaging

SN - 1521-3323

IS - 2

ER -