Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • Fushi Bai
  • Kai Alexander Saalbach
  • Liang Wang
  • Xiaogeng Wang
  • Jens Twiefel

Externe Organisationen

  • Nanjing University of Aeronautics and Astronautics
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)350-355
Seitenumfang6
FachzeitschriftUltrasonics
Jahrgang84
Frühes Online-Datum5 Dez. 2017
PublikationsstatusVeröffentlicht - März 2018

Abstract

During ultrasonic cavitation peening, bubbles repeatedly form and collapse, which leads to high impact loads on the treated surface. At the initial stage of ultrasonic cavitation peening, the most obvious change is plastic deformation instead of mass loss on the treated specimen surface. Meanwhile the plastic deformation is beneficial for mechanical surface properties. As the cavitation exposure time increases, erosion and damage are inflicted on the metal surface due to the increase in the number of collapse events. In this respect, the treatment time is a key parameter to improve the specimen surface properties during this manufacturing process. However, the influence of treatment time on the surface properties has not yet been thoroughly investigated. In this paper, it is the first time to utilize the plastic deformation to evaluate the optimal treatment time at different input power. The plastic deformation can be deduced by the mass loss and the volume change on the treated specimen surface. Using plastic deformation, the modification of surface hardness and roughness are investigated at different cavitation exposure intervals and vibration amplitudes. It is found that significant improvement of the microhardness on the treated surface occurs at the end of incubation period. Higher vibration amplitudes of the horn tip lead to shorter incubation period and higher microhardness.

ASJC Scopus Sachgebiete

Zitieren

Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation. / Bai, Fushi; Saalbach, Kai Alexander; Wang, Liang et al.
in: Ultrasonics, Jahrgang 84, 03.2018, S. 350-355.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Bai F, Saalbach KA, Wang L, Wang X, Twiefel J. Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation. Ultrasonics. 2018 Mär;84:350-355. Epub 2017 Dez 5. doi: 10.1016/j.ultras.2017.12.001
Bai, Fushi ; Saalbach, Kai Alexander ; Wang, Liang et al. / Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation. in: Ultrasonics. 2018 ; Jahrgang 84. S. 350-355.
Download
@article{da5b2e23c4e34e0eb8f9ee5f9314e896,
title = "Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation",
abstract = "During ultrasonic cavitation peening, bubbles repeatedly form and collapse, which leads to high impact loads on the treated surface. At the initial stage of ultrasonic cavitation peening, the most obvious change is plastic deformation instead of mass loss on the treated specimen surface. Meanwhile the plastic deformation is beneficial for mechanical surface properties. As the cavitation exposure time increases, erosion and damage are inflicted on the metal surface due to the increase in the number of collapse events. In this respect, the treatment time is a key parameter to improve the specimen surface properties during this manufacturing process. However, the influence of treatment time on the surface properties has not yet been thoroughly investigated. In this paper, it is the first time to utilize the plastic deformation to evaluate the optimal treatment time at different input power. The plastic deformation can be deduced by the mass loss and the volume change on the treated specimen surface. Using plastic deformation, the modification of surface hardness and roughness are investigated at different cavitation exposure intervals and vibration amplitudes. It is found that significant improvement of the microhardness on the treated surface occurs at the end of incubation period. Higher vibration amplitudes of the horn tip lead to shorter incubation period and higher microhardness.",
keywords = "Microhardness, Plastic deformation, Roughness, Ultrasonic cavitation peening",
author = "Fushi Bai and Saalbach, {Kai Alexander} and Liang Wang and Xiaogeng Wang and Jens Twiefel",
year = "2018",
month = mar,
doi = "10.1016/j.ultras.2017.12.001",
language = "English",
volume = "84",
pages = "350--355",
journal = "Ultrasonics",
issn = "0041-624X",
publisher = "Elsevier",

}

Download

TY - JOUR

T1 - Impact of time on ultrasonic cavitation peening via detection of surface plastic deformation

AU - Bai, Fushi

AU - Saalbach, Kai Alexander

AU - Wang, Liang

AU - Wang, Xiaogeng

AU - Twiefel, Jens

PY - 2018/3

Y1 - 2018/3

N2 - During ultrasonic cavitation peening, bubbles repeatedly form and collapse, which leads to high impact loads on the treated surface. At the initial stage of ultrasonic cavitation peening, the most obvious change is plastic deformation instead of mass loss on the treated specimen surface. Meanwhile the plastic deformation is beneficial for mechanical surface properties. As the cavitation exposure time increases, erosion and damage are inflicted on the metal surface due to the increase in the number of collapse events. In this respect, the treatment time is a key parameter to improve the specimen surface properties during this manufacturing process. However, the influence of treatment time on the surface properties has not yet been thoroughly investigated. In this paper, it is the first time to utilize the plastic deformation to evaluate the optimal treatment time at different input power. The plastic deformation can be deduced by the mass loss and the volume change on the treated specimen surface. Using plastic deformation, the modification of surface hardness and roughness are investigated at different cavitation exposure intervals and vibration amplitudes. It is found that significant improvement of the microhardness on the treated surface occurs at the end of incubation period. Higher vibration amplitudes of the horn tip lead to shorter incubation period and higher microhardness.

AB - During ultrasonic cavitation peening, bubbles repeatedly form and collapse, which leads to high impact loads on the treated surface. At the initial stage of ultrasonic cavitation peening, the most obvious change is plastic deformation instead of mass loss on the treated specimen surface. Meanwhile the plastic deformation is beneficial for mechanical surface properties. As the cavitation exposure time increases, erosion and damage are inflicted on the metal surface due to the increase in the number of collapse events. In this respect, the treatment time is a key parameter to improve the specimen surface properties during this manufacturing process. However, the influence of treatment time on the surface properties has not yet been thoroughly investigated. In this paper, it is the first time to utilize the plastic deformation to evaluate the optimal treatment time at different input power. The plastic deformation can be deduced by the mass loss and the volume change on the treated specimen surface. Using plastic deformation, the modification of surface hardness and roughness are investigated at different cavitation exposure intervals and vibration amplitudes. It is found that significant improvement of the microhardness on the treated surface occurs at the end of incubation period. Higher vibration amplitudes of the horn tip lead to shorter incubation period and higher microhardness.

KW - Microhardness

KW - Plastic deformation

KW - Roughness

KW - Ultrasonic cavitation peening

UR - http://www.scopus.com/inward/record.url?scp=85037524209&partnerID=8YFLogxK

U2 - 10.1016/j.ultras.2017.12.001

DO - 10.1016/j.ultras.2017.12.001

M3 - Article

C2 - 29232591

AN - SCOPUS:85037524209

VL - 84

SP - 350

EP - 355

JO - Ultrasonics

JF - Ultrasonics

SN - 0041-624X