High-speed Digital Image Correlation (DIC) for measuring deformation and vibration of fast rotating fan blades

Publikation: Beitrag in FachzeitschriftKonferenzaufsatz in FachzeitschriftForschungPeer-Review

Autoren

  • Jan Goessling
  • Joerg R. Seume
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Aufsatznummer012075
FachzeitschriftJournal of Physics: Conference Series
Jahrgang2526
Ausgabenummer1
PublikationsstatusVeröffentlicht - 2023
Veranstaltung12th International Conference on Innovation in Aviation and Space for Opening New Horizons, EASN 2022 - Barcelona, Spanien
Dauer: 18 Okt. 202221 Okt. 2022

Abstract

Due to ecological requirements, the bypass-ratio of future civil turbofan engines will be increased. This leads to ultra-high bypass ratio (UHBR) engines, which bring in new challenges concerning the blade material, structural integration, and aeroelastic behaviour of the fan. The ambition of the project Composite fan Aerodynamic, Aeroelastic, and Aeroacoustic Validation Rig (CA3ViAR) is to design and test an open-test-case fan that experiences instability mechanisms, which are representative for UHBR fans of civil aircrafts. The optical measurement technique Digital Image Correlation (DIC) allows for the spatial measurement of deformations. The aim is to apply this technique to measure rotor blade deformation under loading and its vibration due to aeroelastic phenomena to get a better understanding of the structural and aeroelastic behaviour of the composite fan. However, the high rotational speeds, blade vibration frequencies, and expected amplitudes pose challenges for the measurement setup. In this work, a high-speed DIC system is prepared and tested to measure deformation and vibration of a fast rotating blade. Additionally, the requirements for the DIC setup are defined and presented. The expected blade tip speeds in the CA3ViAR project are up to 295 m/s and the blade frequencies of interest up to 650 Hz. Therefore, particular emphasis must be given to the setup in order to eliminate motion blur due to the rotation and to achieve the required frequency. This leads to a setup with synchronised high-speed cameras and a laser to measure frequency vibrations up to 1 kHz with an exposure time below 210 ns. Test measurements are conducted on a stationary beam and an axial blower with a max. blade tip speed of 50 m/s. A data analysis method is developed and described to eliminate the rigid body rotation, analyse the deformation of each blade compared to a reference condition, and analyse the spatial vibration in the frequency domain for a high number of data points per time step. The results of the structural beam are in agreement with the reference measurements and numerical simulations. By analysing the spatial vibration modes of the axial blower, the 1F-flap mode is identified at 38 Hz. In conclusion, this DIC setup shows promising results for future deformation and vibration measurements on a scaled UHBR fan.

ASJC Scopus Sachgebiete

Zitieren

High-speed Digital Image Correlation (DIC) for measuring deformation and vibration of fast rotating fan blades. / Goessling, Jan; Seume, Joerg R.
in: Journal of Physics: Conference Series, Jahrgang 2526, Nr. 1, 012075, 2023.

Publikation: Beitrag in FachzeitschriftKonferenzaufsatz in FachzeitschriftForschungPeer-Review

Goessling J, Seume JR. High-speed Digital Image Correlation (DIC) for measuring deformation and vibration of fast rotating fan blades. Journal of Physics: Conference Series. 2023;2526(1):012075. doi: 10.1088/1742-6596/2526/1/012075
Goessling, Jan ; Seume, Joerg R. / High-speed Digital Image Correlation (DIC) for measuring deformation and vibration of fast rotating fan blades. in: Journal of Physics: Conference Series. 2023 ; Jahrgang 2526, Nr. 1.
Download
@article{1a8b49438f074fb181ea2f74b53832f4,
title = "High-speed Digital Image Correlation (DIC) for measuring deformation and vibration of fast rotating fan blades",
abstract = "Due to ecological requirements, the bypass-ratio of future civil turbofan engines will be increased. This leads to ultra-high bypass ratio (UHBR) engines, which bring in new challenges concerning the blade material, structural integration, and aeroelastic behaviour of the fan. The ambition of the project Composite fan Aerodynamic, Aeroelastic, and Aeroacoustic Validation Rig (CA3ViAR) is to design and test an open-test-case fan that experiences instability mechanisms, which are representative for UHBR fans of civil aircrafts. The optical measurement technique Digital Image Correlation (DIC) allows for the spatial measurement of deformations. The aim is to apply this technique to measure rotor blade deformation under loading and its vibration due to aeroelastic phenomena to get a better understanding of the structural and aeroelastic behaviour of the composite fan. However, the high rotational speeds, blade vibration frequencies, and expected amplitudes pose challenges for the measurement setup. In this work, a high-speed DIC system is prepared and tested to measure deformation and vibration of a fast rotating blade. Additionally, the requirements for the DIC setup are defined and presented. The expected blade tip speeds in the CA3ViAR project are up to 295 m/s and the blade frequencies of interest up to 650 Hz. Therefore, particular emphasis must be given to the setup in order to eliminate motion blur due to the rotation and to achieve the required frequency. This leads to a setup with synchronised high-speed cameras and a laser to measure frequency vibrations up to 1 kHz with an exposure time below 210 ns. Test measurements are conducted on a stationary beam and an axial blower with a max. blade tip speed of 50 m/s. A data analysis method is developed and described to eliminate the rigid body rotation, analyse the deformation of each blade compared to a reference condition, and analyse the spatial vibration in the frequency domain for a high number of data points per time step. The results of the structural beam are in agreement with the reference measurements and numerical simulations. By analysing the spatial vibration modes of the axial blower, the 1F-flap mode is identified at 38 Hz. In conclusion, this DIC setup shows promising results for future deformation and vibration measurements on a scaled UHBR fan.",
author = "Jan Goessling and Seume, {Joerg R.}",
note = "Funding Information: This project has received funding from the Clean Sky 2 Joint Undertaking (JU) under grant agreement No 864256. The JU receives support from the European Union{\textquoteright}s Horizon 2020 research and innovation programme and the Clean Sky 2 JU members other than the Union. The present work reflects only the authors{\textquoteright} view and the European Commission and Clean Sky 2 JU are not responsible for any use that may be made of the information contained herein. ; 12th International Conference on Innovation in Aviation and Space for Opening New Horizons, EASN 2022 ; Conference date: 18-10-2022 Through 21-10-2022",
year = "2023",
doi = "10.1088/1742-6596/2526/1/012075",
language = "English",
volume = "2526",
number = "1",

}

Download

TY - JOUR

T1 - High-speed Digital Image Correlation (DIC) for measuring deformation and vibration of fast rotating fan blades

AU - Goessling, Jan

AU - Seume, Joerg R.

N1 - Funding Information: This project has received funding from the Clean Sky 2 Joint Undertaking (JU) under grant agreement No 864256. The JU receives support from the European Union’s Horizon 2020 research and innovation programme and the Clean Sky 2 JU members other than the Union. The present work reflects only the authors’ view and the European Commission and Clean Sky 2 JU are not responsible for any use that may be made of the information contained herein.

PY - 2023

Y1 - 2023

N2 - Due to ecological requirements, the bypass-ratio of future civil turbofan engines will be increased. This leads to ultra-high bypass ratio (UHBR) engines, which bring in new challenges concerning the blade material, structural integration, and aeroelastic behaviour of the fan. The ambition of the project Composite fan Aerodynamic, Aeroelastic, and Aeroacoustic Validation Rig (CA3ViAR) is to design and test an open-test-case fan that experiences instability mechanisms, which are representative for UHBR fans of civil aircrafts. The optical measurement technique Digital Image Correlation (DIC) allows for the spatial measurement of deformations. The aim is to apply this technique to measure rotor blade deformation under loading and its vibration due to aeroelastic phenomena to get a better understanding of the structural and aeroelastic behaviour of the composite fan. However, the high rotational speeds, blade vibration frequencies, and expected amplitudes pose challenges for the measurement setup. In this work, a high-speed DIC system is prepared and tested to measure deformation and vibration of a fast rotating blade. Additionally, the requirements for the DIC setup are defined and presented. The expected blade tip speeds in the CA3ViAR project are up to 295 m/s and the blade frequencies of interest up to 650 Hz. Therefore, particular emphasis must be given to the setup in order to eliminate motion blur due to the rotation and to achieve the required frequency. This leads to a setup with synchronised high-speed cameras and a laser to measure frequency vibrations up to 1 kHz with an exposure time below 210 ns. Test measurements are conducted on a stationary beam and an axial blower with a max. blade tip speed of 50 m/s. A data analysis method is developed and described to eliminate the rigid body rotation, analyse the deformation of each blade compared to a reference condition, and analyse the spatial vibration in the frequency domain for a high number of data points per time step. The results of the structural beam are in agreement with the reference measurements and numerical simulations. By analysing the spatial vibration modes of the axial blower, the 1F-flap mode is identified at 38 Hz. In conclusion, this DIC setup shows promising results for future deformation and vibration measurements on a scaled UHBR fan.

AB - Due to ecological requirements, the bypass-ratio of future civil turbofan engines will be increased. This leads to ultra-high bypass ratio (UHBR) engines, which bring in new challenges concerning the blade material, structural integration, and aeroelastic behaviour of the fan. The ambition of the project Composite fan Aerodynamic, Aeroelastic, and Aeroacoustic Validation Rig (CA3ViAR) is to design and test an open-test-case fan that experiences instability mechanisms, which are representative for UHBR fans of civil aircrafts. The optical measurement technique Digital Image Correlation (DIC) allows for the spatial measurement of deformations. The aim is to apply this technique to measure rotor blade deformation under loading and its vibration due to aeroelastic phenomena to get a better understanding of the structural and aeroelastic behaviour of the composite fan. However, the high rotational speeds, blade vibration frequencies, and expected amplitudes pose challenges for the measurement setup. In this work, a high-speed DIC system is prepared and tested to measure deformation and vibration of a fast rotating blade. Additionally, the requirements for the DIC setup are defined and presented. The expected blade tip speeds in the CA3ViAR project are up to 295 m/s and the blade frequencies of interest up to 650 Hz. Therefore, particular emphasis must be given to the setup in order to eliminate motion blur due to the rotation and to achieve the required frequency. This leads to a setup with synchronised high-speed cameras and a laser to measure frequency vibrations up to 1 kHz with an exposure time below 210 ns. Test measurements are conducted on a stationary beam and an axial blower with a max. blade tip speed of 50 m/s. A data analysis method is developed and described to eliminate the rigid body rotation, analyse the deformation of each blade compared to a reference condition, and analyse the spatial vibration in the frequency domain for a high number of data points per time step. The results of the structural beam are in agreement with the reference measurements and numerical simulations. By analysing the spatial vibration modes of the axial blower, the 1F-flap mode is identified at 38 Hz. In conclusion, this DIC setup shows promising results for future deformation and vibration measurements on a scaled UHBR fan.

UR - http://www.scopus.com/inward/record.url?scp=85169675845&partnerID=8YFLogxK

U2 - 10.1088/1742-6596/2526/1/012075

DO - 10.1088/1742-6596/2526/1/012075

M3 - Conference article

AN - SCOPUS:85169675845

VL - 2526

JO - Journal of Physics: Conference Series

JF - Journal of Physics: Conference Series

SN - 1742-6588

IS - 1

M1 - 012075

T2 - 12th International Conference on Innovation in Aviation and Space for Opening New Horizons, EASN 2022

Y2 - 18 October 2022 through 21 October 2022

ER -