High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autoren

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksOptical Measurement Systems for Industrial Inspection VIII
Seitenumfang7
PublikationsstatusVeröffentlicht - 13 Mai 2013
VeranstaltungOptical Measurement Systems for Industrial Inspection VIII - Munich, Deutschland
Dauer: 13 Mai 201316 Mai 2013

Publikationsreihe

NameProceedings of SPIE - The International Society for Optical Engineering
Band8788
ISSN (Print)0277-786X
ISSN (elektronisch)1996-756X

Abstract

The paper introduces a new fibrescopic micro fringe projector, showing the special requirements of micro fringe projection in combination with coupling to flexible image fibre bundles. So far performed example applications, such as measurements of deep drawing tools, will be shown and difficulties of certain geometries, such as internal gearing elements with steep flank gradients are discussed. Due to the miniaturization of the fringe pattern into a 2 mm diameter fibre bundle and the decrease of resolution in the bundle, a decrease of contrast has to be accepted. That leads to a fading of the sharp edges of black/white crossovers to sine like characteristics on the detection camera. Methods for the compensation of these artifacts in the beforehand made calibration and during the acquisition of the measurement data will be presented. Fitted applications of the conventional grey code technique will be as well introduced and compared as the developing method of encoded phase shift. In the current state the newly designed fringe projector is connected to a high resolution coordinate measurement machine (CMM). Measurement data and achievable resolutions of the connected systems will as well be presented, giving information about realizable measuring volumes.

ASJC Scopus Sachgebiete

Zitieren

High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection. / Ohrt, Christoph; Kästner, Markus; Reithmeier, Eduard.
Optical Measurement Systems for Industrial Inspection VIII. 2013. 878817 (Proceedings of SPIE - The International Society for Optical Engineering; Band 8788).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Ohrt, C, Kästner, M & Reithmeier, E 2013, High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection. in Optical Measurement Systems for Industrial Inspection VIII., 878817, Proceedings of SPIE - The International Society for Optical Engineering, Bd. 8788, Optical Measurement Systems for Industrial Inspection VIII, Munich, Deutschland, 13 Mai 2013. https://doi.org/10.1117/12.2020440
Ohrt, C., Kästner, M., & Reithmeier, E. (2013). High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection. In Optical Measurement Systems for Industrial Inspection VIII Artikel 878817 (Proceedings of SPIE - The International Society for Optical Engineering; Band 8788). https://doi.org/10.1117/12.2020440
Ohrt C, Kästner M, Reithmeier E. High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection. in Optical Measurement Systems for Industrial Inspection VIII. 2013. 878817. (Proceedings of SPIE - The International Society for Optical Engineering). doi: 10.1117/12.2020440
Ohrt, Christoph ; Kästner, Markus ; Reithmeier, Eduard. / High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection. Optical Measurement Systems for Industrial Inspection VIII. 2013. (Proceedings of SPIE - The International Society for Optical Engineering).
Download
@inproceedings{0c4605d4dccf4f018d6a4b37eb3bee1e,
title = "High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection",
abstract = "The paper introduces a new fibrescopic micro fringe projector, showing the special requirements of micro fringe projection in combination with coupling to flexible image fibre bundles. So far performed example applications, such as measurements of deep drawing tools, will be shown and difficulties of certain geometries, such as internal gearing elements with steep flank gradients are discussed. Due to the miniaturization of the fringe pattern into a 2 mm diameter fibre bundle and the decrease of resolution in the bundle, a decrease of contrast has to be accepted. That leads to a fading of the sharp edges of black/white crossovers to sine like characteristics on the detection camera. Methods for the compensation of these artifacts in the beforehand made calibration and during the acquisition of the measurement data will be presented. Fitted applications of the conventional grey code technique will be as well introduced and compared as the developing method of encoded phase shift. In the current state the newly designed fringe projector is connected to a high resolution coordinate measurement machine (CMM). Measurement data and achievable resolutions of the connected systems will as well be presented, giving information about realizable measuring volumes.",
keywords = "Endoscopy, Fiber optical image bundle, Fringe projection, GRIN-Optics, Measuring Endoscopy",
author = "Christoph Ohrt and Markus K{\"a}stner and Eduard Reithmeier",
year = "2013",
month = may,
day = "13",
doi = "10.1117/12.2020440",
language = "English",
isbn = "9780819496041",
series = "Proceedings of SPIE - The International Society for Optical Engineering",
booktitle = "Optical Measurement Systems for Industrial Inspection VIII",
note = "Optical Measurement Systems for Industrial Inspection VIII ; Conference date: 13-05-2013 Through 16-05-2013",

}

Download

TY - GEN

T1 - High resolution measurements of filigree, inner geometries with endoscopic micro fringe projection

AU - Ohrt, Christoph

AU - Kästner, Markus

AU - Reithmeier, Eduard

PY - 2013/5/13

Y1 - 2013/5/13

N2 - The paper introduces a new fibrescopic micro fringe projector, showing the special requirements of micro fringe projection in combination with coupling to flexible image fibre bundles. So far performed example applications, such as measurements of deep drawing tools, will be shown and difficulties of certain geometries, such as internal gearing elements with steep flank gradients are discussed. Due to the miniaturization of the fringe pattern into a 2 mm diameter fibre bundle and the decrease of resolution in the bundle, a decrease of contrast has to be accepted. That leads to a fading of the sharp edges of black/white crossovers to sine like characteristics on the detection camera. Methods for the compensation of these artifacts in the beforehand made calibration and during the acquisition of the measurement data will be presented. Fitted applications of the conventional grey code technique will be as well introduced and compared as the developing method of encoded phase shift. In the current state the newly designed fringe projector is connected to a high resolution coordinate measurement machine (CMM). Measurement data and achievable resolutions of the connected systems will as well be presented, giving information about realizable measuring volumes.

AB - The paper introduces a new fibrescopic micro fringe projector, showing the special requirements of micro fringe projection in combination with coupling to flexible image fibre bundles. So far performed example applications, such as measurements of deep drawing tools, will be shown and difficulties of certain geometries, such as internal gearing elements with steep flank gradients are discussed. Due to the miniaturization of the fringe pattern into a 2 mm diameter fibre bundle and the decrease of resolution in the bundle, a decrease of contrast has to be accepted. That leads to a fading of the sharp edges of black/white crossovers to sine like characteristics on the detection camera. Methods for the compensation of these artifacts in the beforehand made calibration and during the acquisition of the measurement data will be presented. Fitted applications of the conventional grey code technique will be as well introduced and compared as the developing method of encoded phase shift. In the current state the newly designed fringe projector is connected to a high resolution coordinate measurement machine (CMM). Measurement data and achievable resolutions of the connected systems will as well be presented, giving information about realizable measuring volumes.

KW - Endoscopy

KW - Fiber optical image bundle

KW - Fringe projection

KW - GRIN-Optics

KW - Measuring Endoscopy

UR - http://www.scopus.com/inward/record.url?scp=84880758359&partnerID=8YFLogxK

U2 - 10.1117/12.2020440

DO - 10.1117/12.2020440

M3 - Conference contribution

AN - SCOPUS:84880758359

SN - 9780819496041

T3 - Proceedings of SPIE - The International Society for Optical Engineering

BT - Optical Measurement Systems for Industrial Inspection VIII

T2 - Optical Measurement Systems for Industrial Inspection VIII

Y2 - 13 May 2013 through 16 May 2013

ER -