High frequency fatigue testing of butt welds with a new magnet resonance machine

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Autorschaft

  • C. Keindorf
  • P. Schaumann
  • H. Ahmed
  • P. Goes
  • M. Vermeulen

Organisationseinheiten

Externe Organisationen

  • SKI Ingenieurges. mbH
  • ArcelorMittal
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Titel des SammelwerksProc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010
Seiten149-156
Seitenumfang8
PublikationsstatusVeröffentlicht - 2010
VeranstaltungInternational Conference on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conjunction with the 63rd Annual Assembly of the International Institute of Welding, IIW 2010 - Istanbul, Türkei
Dauer: 11 Juli 201017 Juli 2010

Publikationsreihe

NameProc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010

Abstract

A new magnet resonance machine has been developed to carry out high frequency fatigue tests for transverse butt welds. The technology uses the first natural frequency of a resonance body which consists of two steel beams. Due to four magnets at the ends of the steel beams a harmonic cyclic loading is applied. The maximum frequency for the fatigue tests is 400 Hz. The system allows to test specimens with transverse butt welds up to 109 cycles with moderate values for the mean force and amplitude. The test program comprised more than 110 specimens for analysing several influences, namely: (i) frequency of the test machine, (ii) temperature at hot spots and (iii) steel grade of the specimens. In addition, a test series was carried out to compare the as welded and treated conditions of butt welds. Some test specimens showing fatigue cracks after 108 cycles will be also documented.

ASJC Scopus Sachgebiete

Zitieren

High frequency fatigue testing of butt welds with a new magnet resonance machine. / Keindorf, C.; Schaumann, P.; Ahmed, H. et al.
Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010. 2010. S. 149-156 (Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010).

Publikation: Beitrag in Buch/Bericht/Sammelwerk/KonferenzbandAufsatz in KonferenzbandForschungPeer-Review

Keindorf, C, Schaumann, P, Ahmed, H, Goes, P & Vermeulen, M 2010, High frequency fatigue testing of butt welds with a new magnet resonance machine. in Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010. Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010, S. 149-156, International Conference on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conjunction with the 63rd Annual Assembly of the International Institute of Welding, IIW 2010, Istanbul, Türkei, 11 Juli 2010.
Keindorf, C., Schaumann, P., Ahmed, H., Goes, P., & Vermeulen, M. (2010). High frequency fatigue testing of butt welds with a new magnet resonance machine. In Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010 (S. 149-156). (Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010).
Keindorf C, Schaumann P, Ahmed H, Goes P, Vermeulen M. High frequency fatigue testing of butt welds with a new magnet resonance machine. in Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010. 2010. S. 149-156. (Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010).
Keindorf, C. ; Schaumann, P. ; Ahmed, H. et al. / High frequency fatigue testing of butt welds with a new magnet resonance machine. Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010. 2010. S. 149-156 (Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010).
Download
@inproceedings{05ef3978e28e4858b6d52b96bfcb1303,
title = "High frequency fatigue testing of butt welds with a new magnet resonance machine",
abstract = "A new magnet resonance machine has been developed to carry out high frequency fatigue tests for transverse butt welds. The technology uses the first natural frequency of a resonance body which consists of two steel beams. Due to four magnets at the ends of the steel beams a harmonic cyclic loading is applied. The maximum frequency for the fatigue tests is 400 Hz. The system allows to test specimens with transverse butt welds up to 109 cycles with moderate values for the mean force and amplitude. The test program comprised more than 110 specimens for analysing several influences, namely: (i) frequency of the test machine, (ii) temperature at hot spots and (iii) steel grade of the specimens. In addition, a test series was carried out to compare the as welded and treated conditions of butt welds. Some test specimens showing fatigue cracks after 108 cycles will be also documented.",
keywords = "Butt weld, Fatigue tests, Giga cycle, High frequency, High strength steel, Magnet resonance machine",
author = "C. Keindorf and P. Schaumann and H. Ahmed and P. Goes and M. Vermeulen",
year = "2010",
language = "English",
isbn = "9786056141911",
series = "Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010",
pages = "149--156",
booktitle = "Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010",
note = "International Conference on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conjunction with the 63rd Annual Assembly of the International Institute of Welding, IIW 2010 ; Conference date: 11-07-2010 Through 17-07-2010",

}

Download

TY - GEN

T1 - High frequency fatigue testing of butt welds with a new magnet resonance machine

AU - Keindorf, C.

AU - Schaumann, P.

AU - Ahmed, H.

AU - Goes, P.

AU - Vermeulen, M.

PY - 2010

Y1 - 2010

N2 - A new magnet resonance machine has been developed to carry out high frequency fatigue tests for transverse butt welds. The technology uses the first natural frequency of a resonance body which consists of two steel beams. Due to four magnets at the ends of the steel beams a harmonic cyclic loading is applied. The maximum frequency for the fatigue tests is 400 Hz. The system allows to test specimens with transverse butt welds up to 109 cycles with moderate values for the mean force and amplitude. The test program comprised more than 110 specimens for analysing several influences, namely: (i) frequency of the test machine, (ii) temperature at hot spots and (iii) steel grade of the specimens. In addition, a test series was carried out to compare the as welded and treated conditions of butt welds. Some test specimens showing fatigue cracks after 108 cycles will be also documented.

AB - A new magnet resonance machine has been developed to carry out high frequency fatigue tests for transverse butt welds. The technology uses the first natural frequency of a resonance body which consists of two steel beams. Due to four magnets at the ends of the steel beams a harmonic cyclic loading is applied. The maximum frequency for the fatigue tests is 400 Hz. The system allows to test specimens with transverse butt welds up to 109 cycles with moderate values for the mean force and amplitude. The test program comprised more than 110 specimens for analysing several influences, namely: (i) frequency of the test machine, (ii) temperature at hot spots and (iii) steel grade of the specimens. In addition, a test series was carried out to compare the as welded and treated conditions of butt welds. Some test specimens showing fatigue cracks after 108 cycles will be also documented.

KW - Butt weld

KW - Fatigue tests

KW - Giga cycle

KW - High frequency

KW - High strength steel

KW - Magnet resonance machine

UR - http://www.scopus.com/inward/record.url?scp=79952602780&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:79952602780

SN - 9786056141911

T3 - Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010

SP - 149

EP - 156

BT - Proc. of the Int. Conf. on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conj. with the 63rd Annual Assembly of IIW 2010

T2 - International Conference on Advances in Welding Science and Technology for Construction, Energy and Transportation, AWST 2010, held in Conjunction with the 63rd Annual Assembly of the International Institute of Welding, IIW 2010

Y2 - 11 July 2010 through 17 July 2010

ER -