Hand-projector Self-calibration Using Structured Light.

Publikation: KonferenzbeitragPaperForschungPeer-Review

Autoren

Organisationseinheiten

Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten85-91
Seitenumfang7
PublikationsstatusVeröffentlicht - 2014
Veranstaltung2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO) - Vienna, Austria, Wien, Österreich
Dauer: 1 Sept. 20143 Sept. 2014

Konferenz

Konferenz2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO)
KurztitelICINCO
Land/GebietÖsterreich
OrtWien
Zeitraum1 Sept. 20143 Sept. 2014

Abstract

This paper describes two methods for determining the extrinsic calibration parameters of a projector with respect to the robot hand. One of them simultaneously solves the transformation between a camera with respect to the robot base. Self-calibration means that no sort of calibration rig like a chessboard is needed. Since the projector has no exteroceptive capabilities, a camera is placed in the environment or rigidly attached to the robot base to detect the projected pattern. At different robot configurations correspondences between the camera and projector are established to recover the transformation between them up to an unknown scale factor. The common known formulations AX = XB and AX = ZB can be arranged in a linear form with respect to the unknown extrinsic parameters and scale factors, and solved in least square sense.

ASJC Scopus Sachgebiete

Zitieren

Hand-projector Self-calibration Using Structured Light. / Wieghardt, Christian Sebastian; Wagner, Bernardo.
2014. 85-91 Beitrag in 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO), Wien, Österreich.

Publikation: KonferenzbeitragPaperForschungPeer-Review

Wieghardt, CS & Wagner, B 2014, 'Hand-projector Self-calibration Using Structured Light.', Beitrag in 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO), Wien, Österreich, 1 Sept. 2014 - 3 Sept. 2014 S. 85-91. https://doi.org/10.5220/0005065200850091
Wieghardt, C. S., & Wagner, B. (2014). Hand-projector Self-calibration Using Structured Light.. 85-91. Beitrag in 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO), Wien, Österreich. https://doi.org/10.5220/0005065200850091
Wieghardt CS, Wagner B. Hand-projector Self-calibration Using Structured Light.. 2014. Beitrag in 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO), Wien, Österreich. doi: 10.5220/0005065200850091
Wieghardt, Christian Sebastian ; Wagner, Bernardo. / Hand-projector Self-calibration Using Structured Light. Beitrag in 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO), Wien, Österreich.7 S.
Download
@conference{d03d6e00c24a49e1978a035364daa10e,
title = "Hand-projector Self-calibration Using Structured Light.",
abstract = "This paper describes two methods for determining the extrinsic calibration parameters of a projector with respect to the robot hand. One of them simultaneously solves the transformation between a camera with respect to the robot base. Self-calibration means that no sort of calibration rig like a chessboard is needed. Since the projector has no exteroceptive capabilities, a camera is placed in the environment or rigidly attached to the robot base to detect the projected pattern. At different robot configurations correspondences between the camera and projector are established to recover the transformation between them up to an unknown scale factor. The common known formulations AX = XB and AX = ZB can be arranged in a linear form with respect to the unknown extrinsic parameters and scale factors, and solved in least square sense.",
keywords = "Motion estimation, Pattern projection, Self-calibration, Structured light system",
author = "Wieghardt, {Christian Sebastian} and Bernardo Wagner",
note = "Copyright: Copyright 2020 Elsevier B.V., All rights reserved.; 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO), ICINCO ; Conference date: 01-09-2014 Through 03-09-2014",
year = "2014",
doi = "10.5220/0005065200850091",
language = "English",
pages = "85--91",

}

Download

TY - CONF

T1 - Hand-projector Self-calibration Using Structured Light.

AU - Wieghardt, Christian Sebastian

AU - Wagner, Bernardo

N1 - Copyright: Copyright 2020 Elsevier B.V., All rights reserved.

PY - 2014

Y1 - 2014

N2 - This paper describes two methods for determining the extrinsic calibration parameters of a projector with respect to the robot hand. One of them simultaneously solves the transformation between a camera with respect to the robot base. Self-calibration means that no sort of calibration rig like a chessboard is needed. Since the projector has no exteroceptive capabilities, a camera is placed in the environment or rigidly attached to the robot base to detect the projected pattern. At different robot configurations correspondences between the camera and projector are established to recover the transformation between them up to an unknown scale factor. The common known formulations AX = XB and AX = ZB can be arranged in a linear form with respect to the unknown extrinsic parameters and scale factors, and solved in least square sense.

AB - This paper describes two methods for determining the extrinsic calibration parameters of a projector with respect to the robot hand. One of them simultaneously solves the transformation between a camera with respect to the robot base. Self-calibration means that no sort of calibration rig like a chessboard is needed. Since the projector has no exteroceptive capabilities, a camera is placed in the environment or rigidly attached to the robot base to detect the projected pattern. At different robot configurations correspondences between the camera and projector are established to recover the transformation between them up to an unknown scale factor. The common known formulations AX = XB and AX = ZB can be arranged in a linear form with respect to the unknown extrinsic parameters and scale factors, and solved in least square sense.

KW - Motion estimation

KW - Pattern projection

KW - Self-calibration

KW - Structured light system

UR - http://www.scopus.com/inward/record.url?scp=84910069988&partnerID=8YFLogxK

U2 - 10.5220/0005065200850091

DO - 10.5220/0005065200850091

M3 - Paper

SP - 85

EP - 91

T2 - 2014 11th International Conference on Informatics in Control, Automation and Robotics (ICINCO)

Y2 - 1 September 2014 through 3 September 2014

ER -