Abstract
The use of a TEM-cell anechoic-chamber hybrid, the GTEM cell for EMI testing is discussed. The hybrid chamber may be used for both susceptibility and radiated emission testing and is well suited for time domain as well as continuous wave (CW) measurements. The chamber has extremely broadband characteristics, with a usable frequency range from DC to GHz (approximately 18 GHz). The TEM mode is used to simulate an incident plane wave for susceptibility testing. Radiated emission data obtained in the hybrid chamber may be used to simulate open area test sites (OATS) or free space measurements. Applications will be stressed and a variety of representative data will be shown.
ASJC Scopus Sachgebiete
- Ingenieurwesen (insg.)
- Elektrotechnik und Elektronik
Zitieren
- Standard
- Harvard
- Apa
- Vancouver
- BibTex
- RIS
in: IEE Conference Publication, Nr. 326, 1990, S. 152-156.
Publikation: Beitrag in Fachzeitschrift › Konferenzaufsatz in Fachzeitschrift › Forschung › Peer-Review
}
TY - JOUR
T1 - GTEM cell concept; applications of this new EMC test environment to radiated emission and susceptibility measurements
AU - Garbe, H.
AU - Hansen, D.
PY - 1990
Y1 - 1990
N2 - The use of a TEM-cell anechoic-chamber hybrid, the GTEM cell for EMI testing is discussed. The hybrid chamber may be used for both susceptibility and radiated emission testing and is well suited for time domain as well as continuous wave (CW) measurements. The chamber has extremely broadband characteristics, with a usable frequency range from DC to GHz (approximately 18 GHz). The TEM mode is used to simulate an incident plane wave for susceptibility testing. Radiated emission data obtained in the hybrid chamber may be used to simulate open area test sites (OATS) or free space measurements. Applications will be stressed and a variety of representative data will be shown.
AB - The use of a TEM-cell anechoic-chamber hybrid, the GTEM cell for EMI testing is discussed. The hybrid chamber may be used for both susceptibility and radiated emission testing and is well suited for time domain as well as continuous wave (CW) measurements. The chamber has extremely broadband characteristics, with a usable frequency range from DC to GHz (approximately 18 GHz). The TEM mode is used to simulate an incident plane wave for susceptibility testing. Radiated emission data obtained in the hybrid chamber may be used to simulate open area test sites (OATS) or free space measurements. Applications will be stressed and a variety of representative data will be shown.
UR - http://www.scopus.com/inward/record.url?scp=0025540312&partnerID=8YFLogxK
M3 - Conference article
AN - SCOPUS:0025540312
SP - 152
EP - 156
JO - IEE Conference Publication
JF - IEE Conference Publication
SN - 0537-9989
IS - 326
T2 - 7th International Conference on Electromagnetic Compatibility
Y2 - 28 August 1990 through 31 August 1990
ER -