Formation of lubricant film in rotary sealing contacts: Part II-A new measuring principle for lubricant film thickness

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Autoren

  • G. Poll
  • A. Gabelli

Externe Organisationen

  • SKF BV (Engineering and Research Center), Nieuwegein, NL
Forschungs-netzwerk anzeigen

Details

OriginalspracheEnglisch
Seiten (von - bis)290-296
Seitenumfang7
FachzeitschriftJournal of tribology
Jahrgang114
Ausgabenummer2
PublikationsstatusVeröffentlicht - Apr. 1992
Extern publiziertJa

Abstract

The development of models for the elastohydrodynamic lubrication of rotary lip seals requires the measurement of the film thickness under a real seal. A new method has been developed for this purpose which is based on the use of lubricant oils in which magnetite particles are suspended (so-called magnetic fluids). A change in the fluid film thickness will create a change in the impedance of the coil of the measuring circuit, the magnetic flux of which is directed through the oil film of the contact area. The advantage of this technique is that minimal modifications have to be applied to the tribological system under examination. Initial measurements carried out with a model rubber lip seal provided new insight into the build-up of a lubricant film as a function of the rotary speed and allowed comparison with the results of a theoretical model for the analysis of lip seal lubrication developed in parallel.

ASJC Scopus Sachgebiete

Zitieren

Formation of lubricant film in rotary sealing contacts: Part II-A new measuring principle for lubricant film thickness. / Poll, G.; Gabelli, A.
in: Journal of tribology, Jahrgang 114, Nr. 2, 04.1992, S. 290-296.

Publikation: Beitrag in FachzeitschriftArtikelForschungPeer-Review

Download
@article{2f99e33f032249389c17d90945078d88,
title = "Formation of lubricant film in rotary sealing contacts: Part II-A new measuring principle for lubricant film thickness",
abstract = "The development of models for the elastohydrodynamic lubrication of rotary lip seals requires the measurement of the film thickness under a real seal. A new method has been developed for this purpose which is based on the use of lubricant oils in which magnetite particles are suspended (so-called magnetic fluids). A change in the fluid film thickness will create a change in the impedance of the coil of the measuring circuit, the magnetic flux of which is directed through the oil film of the contact area. The advantage of this technique is that minimal modifications have to be applied to the tribological system under examination. Initial measurements carried out with a model rubber lip seal provided new insight into the build-up of a lubricant film as a function of the rotary speed and allowed comparison with the results of a theoretical model for the analysis of lip seal lubrication developed in parallel.",
author = "G. Poll and A. Gabelli",
year = "1992",
month = apr,
doi = "10.1115/1.2920886",
language = "English",
volume = "114",
pages = "290--296",
journal = "Journal of tribology",
issn = "0742-4787",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "2",

}

Download

TY - JOUR

T1 - Formation of lubricant film in rotary sealing contacts

T2 - Part II-A new measuring principle for lubricant film thickness

AU - Poll, G.

AU - Gabelli, A.

PY - 1992/4

Y1 - 1992/4

N2 - The development of models for the elastohydrodynamic lubrication of rotary lip seals requires the measurement of the film thickness under a real seal. A new method has been developed for this purpose which is based on the use of lubricant oils in which magnetite particles are suspended (so-called magnetic fluids). A change in the fluid film thickness will create a change in the impedance of the coil of the measuring circuit, the magnetic flux of which is directed through the oil film of the contact area. The advantage of this technique is that minimal modifications have to be applied to the tribological system under examination. Initial measurements carried out with a model rubber lip seal provided new insight into the build-up of a lubricant film as a function of the rotary speed and allowed comparison with the results of a theoretical model for the analysis of lip seal lubrication developed in parallel.

AB - The development of models for the elastohydrodynamic lubrication of rotary lip seals requires the measurement of the film thickness under a real seal. A new method has been developed for this purpose which is based on the use of lubricant oils in which magnetite particles are suspended (so-called magnetic fluids). A change in the fluid film thickness will create a change in the impedance of the coil of the measuring circuit, the magnetic flux of which is directed through the oil film of the contact area. The advantage of this technique is that minimal modifications have to be applied to the tribological system under examination. Initial measurements carried out with a model rubber lip seal provided new insight into the build-up of a lubricant film as a function of the rotary speed and allowed comparison with the results of a theoretical model for the analysis of lip seal lubrication developed in parallel.

UR - http://www.scopus.com/inward/record.url?scp=0026848066&partnerID=8YFLogxK

U2 - 10.1115/1.2920886

DO - 10.1115/1.2920886

M3 - Article

AN - SCOPUS:0026848066

VL - 114

SP - 290

EP - 296